ATIM_ACW-THAQ_UG_FR_V1.7
Error and alarm generic frame
If the Timestamp is activated, 4 bytes with the Timestamp value will be preceded by the header (byte 1).
For each error message, a header is inserted and is formed as follows:
The
message index
field is used to prioritize messages when several errors occur.
The
length of the error message
field indicates the size in bytes of the error message.
The following byte identifies the nature of the error that occurred:
Byte1 - Header
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
New
generation
= 1
Timestamp
Measureme
nt frame
= 0
Reserved
= 0
Error frame
= 0x0e
Byte2 -
Error frame header
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Index of message
Error message length
Octet 3 - En-tête
Message d’erreur
Error code
Nature of the error
Description
0x81
ERR_UNKNOWN
0x82
ERR_BUF_SMALLER
The data table is full, impossible to write any additional data
0x83
ERR_DEPTH_HISTORIC_OUT_OF_RANGE
The history depth is too large or too small for the frame
0x84
ERR_NB_SAMPLE_OUT_OF_RANGE
The number of samplings is too large or too small for the
frame
0x85
ERR_NWAY_OUT_OF_RANGE
The number of the channel in the header of the frame is too
large or too small
0x86
ERR_TYPEWAY_OUT_OF_RANGE
The type of measurement in the frame header is too large or
too small
0x87
ERR_SAMPLING_PERIOD
Bad structure of sampling period
0x88
ERR_SUBTASK_END
End of a sub-task after leaving an infinite loop
0x89
ERR_NULL_POINTER
Pointer with value “NULL”
0x8A
ERR_BATTERY_LEVEL_DEAD
Critical battery level
0x8B
ERR_EEPROM
EEPROM is corrupted