23
ATIM_ACW-DINRSM_UG_EN_V2.8
b.
Commands
Restart
To restart the ACW-DIN-RSM remotely, you must send it the following command:
Byte 1
Byte 2
0x01
0x01
The ACW will restart and will not send a confirmation.
About
To obtain information about the ACW-DINRSM, you must send it the following command:
Byte 1
Byte 2
0x01
0x02
The ACW will return the information in the following format:
NOTE
In LoRaWAN, the four high-order bytes are replaced by 0.
Description and Value
Byte 1
Response to command frames: 0x07
Byte 2
‘About’ command: 0x02
Byte 3
Type of ACW: DIN RS
–
0x06
Byte 4
ACW version (LSB)
Byte 5
ACW version (MSB)
Byte 6
Radio type:
1.
Local
–
0x01
2.
Local long distance
–
0x02
3.
Sigfox uplink only
–
0x03
4.
Sigfox uplink/downlink - 0x04
5.
LoRaWAN
–
0x05
Byte 7
Radio version (LSB)
Byte 8
Radio version (MSB)
Byte 9,n
Serial number (devEUI|sfx) (MSB first).