Electric lock powered by door
station lock output.
Note:
The jumper must be set correctly (fig. 1).
The lock output is limited to 12Vdc, and a
maximum current of 250mA.
Setting lock type - DIP switch 5
ON
Fail locked
(normally closed)
OFF
Fail unlocked
(normally open)
fig.1
Electric lock powered by
additional power supply
Note:
The jumper must be set correctly (fig. 2).
The power supply must be used accordingly
to lock specification.
The dry contact is limited to 24Vac or 24dc,
and a maximum current of 1000mA.
Setting lock type - DIP switch 5
ON
Fail locked
(normally closed)
OFF
Fail unlocked
(normally open)
fig.2