Video camera module A3101
Specification:
Power supply: 26Vdc (supplied by A2100)
Power Consumption: 1W standby, 5W active
Unlock Power output: 12Vdc, 250mA
Unlock time: 1~99s
Working temperature: 20ºC ~ +55ºC
Dimension: 83(H) x 100(W) x 38(D)mm
A3101 Terminals
SET (1)
DIP switches for system configuration.
JP-LK (2)
Jumper for setting state of the
NO
contact
CN/KMB (3)
Call button module A2400 connection port
CN/T-COIL (4)
Not in use
BUS (5)
L1, L2 bus line connecting to terminal
BUS(DS) on the power supply
CN-LK (6)
+12V
12VDC power output.
LK-
Power ground.
LK+
Contact of the relay.
NO
Normally open/closed contact (use
JP-LK jumper to set)
EB+
Exit button connection port.
EB-
Exit button connection port.
7. CN/FUN
Not in use
8. CN/WGN
Not in use