2 Wire System 

Installation Manual 

 

 

Содержание A2400

Страница 1: ...2 Wire System Installation Manual ...

Страница 2: ...ors can be connected to a single call button Maximum of 4 monitors can be connected in daisy chain configuration Maximum of 8 monitors can be connected to single A2200 in distributor mode DIP switch 1 OFF Maximum of 4 A2200 units can be connected to single A2200 in raiser mode DIP switch 1 ON Cable distances CAT5e UTP cores twisted by colour code Twist the cores of CAT5e UTP as shown in the image ...

Страница 3: ...switches for system configuration JP LK 2 Jumper for setting state of the NO contact CN KMB 3 Call button module A2400 connection port CN T COIL 4 Not in use BUS 5 L1 L2 bus line connecting to terminal BUS DS on the power supply CN LK 6 12V 12VDC power output LK Power ground LK Contact of the relay NO Normally open closed contact use JP LK jumper to set EB Exit button connection port EB Exit butto...

Страница 4: ...lock time 0 is the default setting for one second delay and 1 is the setting for five seconds delay DIP switch 6 is for activating keys A and B which are used for programming camera module functions see next section The default setting for this DIP switch is 0 Video module functions and programming Activating touch keys A and B Key A and key B cannot be seen on the camera module until activated To...

Страница 5: ...ing Time delay is indicated by the number of times that the Status indicator blinks set in seconds For example The Status indicator blinks four times that means the unlocking time is 4 seconds Sound setting When the Camera Module is in standby 1 Press and hold Key A for 3 seconds to enter the Sound Option Mode the Status indicator will turn on and the current sound will play 2 Press Key A again to...

Страница 6: ... setting JP LK 1 2 Normally closed mode 2 3 Normally open mode Fail Locked Fail Unlocked Electric lock external power 1 The external power supply must be used accordingly to lock specification 2 The jumper must be taken off before connecting 3 Set lock type using touch keys A and B see module programming Fail Locked Mode 0 default Fail Unlocked Mode 1 ...

Страница 7: ...odule A2400 Terminals 1 INPUT Connect to CN KMB port video module 2 OUTPUT Connect to next call module 3 J3 Call buttons 1 3 5 7 4 J4 Call buttons 2 4 6 8 Single module connections Connecting multiple modules Max 4 ...

Страница 8: ...System layout Distributor mode ...

Страница 9: ......

Страница 10: ...System layout Riser mode ...

Страница 11: ......