ATIGO A1702 Скачать руководство пользователя страница 3

Video Receiver  A1702 

 

Parts & Functions  

 
Key functions 

 

Speaker 

 

Enables  communication  with  the  visitor

 

Talk/Mon  button 

 

Press  for hands-free  communication 
with the  visitor 

 

Press  to  view the  camera  in  standby 

LCD screen 

 

Display the  image of  the  visitor 

Power/Do  Not 
Disturb   

 

Show  the  power  status  of  the  system

 

 

Turn  on  Do Not  Disturb  mode

 

Microphone 

 

Transmit audio  to  the  entry  panel  or 
other  monitors

 

Unlock  button 

 

Press  to  unlock  the  door

 

Connection  port 

 

BUS  terminal and  monitor  addressing

 

 

Terminal description 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SW+ / SW- 

Extra  doorbell  call button  connection  port 

Ring / GND 

Extra  buzzer  connection  port 

POW /  GND 

12~16V  extra  power  connection  port 

DIP  sw itches 

Total  6  bits can  be  configured 

Bit1~Bit5 

User code  setting  switch 

Bit6 

Video  impedance  matching  switch 

L1  / L2 

BUS  line terminal 

 
Mounting 

 

A. 

Embed the mounting box into the 
wall. 

 

B. 

Use screws to fasten the 
mounting bracket to the mounting 
box. 

 

C.  Connect the 2 wires cable to the 

unit. 

 

D.  Mount the unit onto the mounting 

bracket. 

 
The suggested installation height is between 
145~160 cm from ground.  

 

Содержание A1702

Страница 1: ...A1702 2 Wire Video Receiver User manual ...

Страница 2: ... adjustments 6 Image adjustments 6 Volume adjustments 6 Door release 6 Call another room or apartment Intercom 6 Do Not Disturb 7 General settings 7 Ring tone setting 7 Ring tone volume 8 Setting screen time 8 Intercom function 8 Restoring the default settings 9 Installer menu 9 Concierge unit 10 Date and time format 10 Unlock mode 11 Unlock time 11 Setting the user code 11 ...

Страница 3: ...unlock the door Connection port BUS terminal and monitor addressing Terminal description SW SW Extra doorbell call button connection port Ring GND Extra buzzer connection port POW GND 12 16V extra power connection port DIP switches Total 6 bits can be configured Bit1 Bit5 User code setting switch Bit6 Video impedance matching switch L1 L2 BUS line terminal Mounting A Embed the mounting boxinto the...

Страница 4: ...age while the receiver is in communication Answering a call 1 Touch Talk Mon button to answer the call To end the call touch the button again 2 If necessary during the call touch the Setting button to display the audio video settings 3 To unlockthe doorto the visitor touch the door lock key button An indicator thatthe door lock has been released will displayon the screen briefly ...

Страница 5: ...door entry panel press the Monitor button to cycle through 3 Touch the Back arrow to return to previous menu Zoom If you want to see more details you can move to the desired positionby touching the magnifying glass button and choose a part on the screen to ZOOMthe image view Note Thisfunction requiresa fisheye cameralens Scale To adjust the Scale of the image use one of the following two modes 1 4...

Страница 6: ... the range zero to nine by pressing the or Door release When a visitor pushesthe call button from the entry panel the receiverwillstart ringing To answer the call touch Talk Monbutton Press the unlock button to release the primarydoor If the call comesfroma secondary entrance press unlock2nd button Checkwith your installer if the lock iselectricand if it can connect to the system Call another room...

Страница 7: ...tivate the Do Not Disturb function Note The indicator changes to GREEN to indicate that the Do Not Disturb function is ON The indicator is GREY when the function is OFF When the function is turned ON you will not receive any calls General settings Ring tone setting The ring calltone can be set individuallyto distinguish different calling sources There are a total of 12 ring tones to choose from 1 ...

Страница 8: ...er 30 secondsof inactivity the screen willturn off This setting can be adjusted as needed by choosing between a range of sixseconds and up to 10 minutes 1 Select Settings from the Main Menu 2 Press the Screen time button 3 Use up and down arrows to scrollthrough the time setting Intercom function The intercom function can be enabled or disabled as required 1 Select Settings from the Main Menu 2 Pr...

Страница 9: ...store button on the side menu 4 Press the Check button to confirm alternativelyif you want to Cancel pressthe X button Note The system willsound a beep when the restore to factorysettingshasfinished Installer menu To enter the Installer menu follow below steps 1 Select Settings from the Main Menu 2 Press and hold for three seconds the Unlock key button 3 On the keypad type the installercode accord...

Страница 10: ...sed as a concierge unit to the system Follow below stepsto enable this function 1 Select Settings from the Main Menu 2 Press and hold for 3 secondsthe Unlock key button 3 On the keypad type a 8004 to enable the concierge function on the monitor b 8005 to disable the concierge function on the monitor Date and time format The format of the date ortime can be set in two ways Follow below stepsto chan...

Страница 11: ... Unlock key button 3 On the keypad type 8401 for one second 8499 for 99 seconds to set the unlocktime Setting the user code On the ATIGO system everyreceiver must have assigned an identification code called User Code DIP Switch addresses The DIP switchesare used to set the user code for each monitorand maximum are 6 Bits Bit 1 Bit 5 are used for addressing Thevalue range is from 0 to 31 a total of...

Страница 12: ...er anyimpact 2 Please clean the screen with a soft cotton cloth without using anyorganicorchemical cleaning agent If necessary please use as little as possible water ordilute soap into water to clean the dust 3 Image distortion may occurif the monitor ismounted too close to magnetic fields like TV s microwaves computers etc 4 Please keep away from high temperatures dust oxidation orwater to avoid ...