GENERAL INFORMATION AND FEATURES
210-0197_Libretto_TX_ATI_2020-02_ATI-eng
7
ed. 2020-02
A. break-windproof pulling device
B. atmospheric burner
C. instrument panel
D. boiler
E. the combustion chamber
9 EQUIPMENT COMPONENTS
A. THERMOMETER
Measure the temperature inside the tank.
B. RED LIGHT BLOCK
Report device lock, to unlock, hold down the button for
3 seconds.
C. SWITCH
It allows switching on and off.
D. LIGHT GREEN POWER
Report proper burner ignition. Comes into operation
when the combustion chamber is fed.
E. THERMOSTAT WATER SAFETY
When the device temperature rises above the
maximum threshold, the safety thermostat comes into
operation by blocking the appliance. To unlock it,
unscrew the lid and hold the button below.
F. THERMOSTAT
Used to adjust the internal temperature of the tank.
G. THERMOSTAT SAFETY SMOKE
When the temperature of the salt fumes beyond the
maximum or in case of incorrect evacuation threshold,
the flue safety thermostat comes into operation by
blocking the appliance. To unlock it, unscrew the lid
and hold the button below.
H. CONTROL UNIT
The control unit has the purpose of controlling, handle
the electrical devices and appliance gas.
I.
PCB CONNECTIONS
The connection card is used to centralize the user
control devices with the controller interface.
J. GAS VALVE
The gas valve allows to manage and control the gas
inlet to the combustion chamber.