background image

INSTALLATION INSTRUCTIONS

 

 

210-0197_Libretto_TX_ATI_2020-02_ATI-eng 

12 

ed. 2020-02 

 

16 HYDRAULIC CONNECTIONS 

 

The appliance will last longer if they are met, as provided by D. LGS. February 2, 2001, 31 (implementation of 

Directive 98/83 / EC on the quality of water intended for human consumption), the following parameters: 

1.  Total hardness: between 10 ° F and 25 ° F.  
2.  PH: comprised between 6 and 8 
3.  Chloride: max 200 mg / l 
4.  Conductivity: max. 2500 mS / cm 

In the presence of water with different parameters to the above, it should be given special care in the periodic 

maintenance of the tank. In particular it must be replaced several times a year the magnesium anode. 
 

 

 

  HYDRAULIC  COMPONENTS  TO 

INSTALL  OBLIGATORILY  (are  not  included 
with the appliance)

 

A.  drain cock and fitting Tee 
B.  expansion vessel capacity of not less than 

5% of the content of the appliance 

C.  softener (only for water with hardness 

greater than 25 ° F)

 

D.  pressure reducer 
E.  of 

chemical 

conditioning 

device 

(polyphosphate) 

F.  filter to remove any impurities, such as 

sand, gravel, mud, etc..  

G.  check valve  
H.  stopcock cold input  
I. 

stopcock hot output  

SAFETY VALVE: l

'Appliance is equipped with a safety valve against excess pressure.  

The component of the function is to download the tank water in the presence of an internal pressure higher than the 
maximum pressure of the tank (for example during the water heating). 

the possible from the valve discharge of dripping water means the presence of an overpressure and the correct 

intervention of the valve. If this happens you must turn off the power and remove the cause of the overpressure 

  the  removal  or  tampering  of  the  safety  valve  constitutes  danger  to  the  user  (in  addition  to  cause  the  non-

recognition of the guarantee for damage from overpressure). 

The  setting  of  the  valve  pressure  is  stamped  on  the  cap  of  the  same  and  is  expressed  in  Bar.  The  fluid  discharged 
during  the  possible  intervention  for  overpressure  must  be  conveyed  downwards  (consider  that  in  the  exhaust  pipe 
downstream decreases the exhaust flow rate. 

If drips are caused by impurities deposited on the valve membrane it is possible to remove them by turning the knob 
and raising the membrane. 

 

 

Содержание TX160

Страница 1: ...TX160 TX220 TX300 TX400 TX600 TX800 ENG Manual installation use and maintenance Original instructions Read and follow these instructions before installing the unit Always keep on hand this manual duri...

Страница 2: ...FUNCTIONAL AND CONSTRUCTION 6 9 EQUIPMENT COMPONENTS 7 10 WIRING 8 11 LOCAL REGULATIONS AND INSTALLATION OF SAFETY 9 12 INSTALLATION 10 13 POSITIONING APPARATUS 10 14 BREAK WIND INSTALLATION DRAW 11 1...

Страница 3: ...by unsupervised children If the appliance should be sold or transferred to another owner ensure that this booklet accompanies the same so that they can be consulted by the new owner and or installer n...

Страница 4: ...parts 1 and 2 are present and that they are not damaged during transport 1 2 TX160 cm 58 x 58 x 185 131 kg cm 46 x 46 x 23 5 kg TX220 cm 78 x 78 x 141 184 kg cm 68 x 68 x 25 6 kg TX300 cm 78 x 78 x 17...

Страница 5: ...8 1 9 1 9 2 1 2 2 NOx emission value mg kWh 54 26 29 36 35 37 Max water pressure kPa 600 600 600 600 600 600 empty weight Kg 118 173 206 243 246 301 full weight Kg 278 393 506 643 831 1 041 electrical...

Страница 6: ...TR I2H G20 20 mbar 8 DESCRIPTION FUNCTIONAL AND CONSTRUCTION The function of this device is to generate hot water through the heat exchange between the combustion products of the burner and the water...

Страница 7: ...threshold the safety thermostat comes into operation by blocking the appliance To unlock it unscrew the lid and hold the button below F THERMOSTAT Used to adjust the internal temperature of the tank G...

Страница 8: ...10 WIRING L Line N Neutral THE Switch SB red lock lamp RESET reset button T Control thermostat SA Power indicator VG1 valve GAS TS Water Safety thermostat TF Flue safety thermostat ACC Ignition elect...

Страница 9: ...n and maintenance the workplace has adequate hygienic conditions with regard to lighting aeration and solidity Wear during installation and maintenance clothing and adequate personal protective equipm...

Страница 10: ...e possibly damaged with tape or clamps If the power cord is damaged it must be replaced by service agent or a similarly qualified person in order to avoid a hazard Incorrect installation can cause dam...

Страница 11: ...pliance so as not to obstruct the path of the fumes Mod 160 Mod 220 300 400 600 800 Make sure that during operation or transportation the B flue safety thermostat bulb has not been damaged or moved fr...

Страница 12: ...to remove any impurities such as sand gravel mud etc G check valve H stopcock cold input I stopcock hot output SAFETY VALVE l Appliance is equipped with a safety valve against excess pressure The com...

Страница 13: ...TX160 TX220 TX300 TX400 TX600 TX800 inlet pressure mbar 37 0 pressure regulating here I m injector pressure mbar 25 5 25 5 27 5 25 0 27 5 27 5 N injectors 2 x 1 35 3 x 1 55 3 x 1 60 3 x 1 60 3 x 1 65...

Страница 14: ...to the specified value through the REG screw on the gas valve To check the value you can use the outlet pressure of P OUT 8 Stick the label contained in the kit to indicate the new type of gas supply...

Страница 15: ...provide a disconnect device not supplied with an opening distance of the contacts that allows complete disconnection in the conditions dictated by the overvoltage category III LINE AND NEUTRAL PLUG TO...

Страница 16: ...iance is sold or transferred to another owner ensure that this booklet accompanies the same so that they can be consulted by the new owner and or installer Do not place any kind on the subject To get...

Страница 17: ...the safety and prolong its life you should have it checked at least once a year by an authorized service center which will act as follows replacing the magnesium anode internal inspection of the boile...

Страница 18: ...th from uncontrolled waste disposal the user is encouraged to separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users...

Страница 19: ...INSTRUCTIONS FOR THE USER 210 0197_Libretto_TX_ATI_2020 02_ATI eng 19 ed 2020 02...

Страница 20: ...210 0197_Libretto_TX_ATI_2020 02_ATI eng 20 ed 2020 02 ATI DI MARIANI SRL Via E Mattei 461 Zona Ind No 4 Torre del Moro 47522 Cesena FC ITALY Tel 0547 609711 www atimariani it info atimariani it...

Отзывы: