ATI Technologies Q-Card Скачать руководство пользователя страница 2

To Key In Function15 Use ‘1’ and ‘5’ Keys
Message =’Fc’ with the feed total cleared to zero.
Press the Side key to clear the display

Serial Number and Software Version: Functions 77 & 2

Run the Function Mode Key Sequence using function 77 for 
the Serial Number or function 2 for the Software Version.

Message =’Sn’ or ‘EP’
Press the Side key to clear the display.

Calibrate: Function 1

This  feature  increases  or  decreases  the  ration  as  a 
percentage of the Run Time value. Set to 100 to deliver ‘flat’ 
ration. Range is 1 through 200.

Run the Function Mode Key Sequence.
Message=’cL’
Key the new calibration value.
Press the Batch(ENTER) key.

Set Feeder Run Time: Function 87

This  feature  sets  the  time  for  which  a  feeder  will  run.

 

Increments are 0.01seconds to a maximum of 9999 (99.99 
seconds).
Run the Function Mode Key Sequence.
Message=’Fc’
Key the new Run Time value. Use trailing zeros.
Press the Batch(ENTER) key.

Batch Feeding

Batch feeding starts at the current stall number and ends at 
the highest stall number on one side.

Press the Batch(ENTER) key.
Message=’Batch’
Press the required ration key. Feeding starts automatically.

Automatic Fuses: Reset

Press key 0(FUSE) to initiate the warning reset.
Clear  the  problem  before  attempting  to  use  that  feeder 
again

Check Calibration value=100
Run  the  Function  Mode  Key  Sequence  using  ‘1’  as  the 
Function Number.
Message=’cL’ with current value.
Key ‘100’
Press Batch(ENTER).

Select the Feeder Run Time

Run the Function Mode Key Sequence using ‘87’ as the 
Function Number.
Message=’Fc’ with current Run Time value.
Press key 15. Feeder 1 will dispense cake.
Weigh the cake. Aim for 500grams.
If the weight is too high or too low:
Press Batch(ENTER).
Key a new Run Time value lower for less cake or higher 
for more cake.
Press Batch(ENTER).
Repeat weighing process above until weight is correct.

Apply the Feeder Run Time

Repeat  the  process  for  the  other  feeders  using  key 
0(FUSE) to step through the feeders or:
Run the Function Mode Key Sequence using ‘87’ as the 
Function Number.
Message=’cL’ with current value.
Press key 11. Message=’AL’.
Key the new Run Time value.
Press Batch(ENTER). The Run Time value will be applied 
to all of the remaining feeders.

Fine Tune Calibrate

Run the Function Mode Key Sequence using ‘1’ as the 
Function Number.
Message=’cL’ with current value.
Feed a single ration and check the weight.
Adjust the ration by altering the Calibration value as a 
percentage.
Press Batch(ENTER).

Set Default Total Display: Function 85 and 86

Select either Total Cumulative Feed (Function 85) or Total 
Cows  Fed  this  Milking  (Function  86).  Whichever  function 
runs becomes the default display.

Run  the  Function  Mode  Key  Sequence  using  the  desired 
function number (85 or 86).
Message =’dd Ftot’ or ‘dd cFEd’
Press Batch(ENTER)

Display Cows Fed this Milking: Function 3

Run the Function Mode Key Sequence.
Message =’cF’ with cows fed total in Totals window.
Press the Side key to clear the display

Clear Cows Fed this Milking Total: Function 13

This total is usually cleared automatically about 30 minutes 
after milking.

Run the Function Mode Key Sequence.
To Key In Function13 Use ‘1’ and ‘3’ Keys
Message =’cF’ with cows fed total cleared to zero.
Press the Side key to clear the display

Display Feed Dispensed this Milking: Function 4

Run the Function Mode Key Sequence.
Message =’MF’ with the feed total in Totals window.
Press the Side key to clear the display

Clear Feed Dispensed this Milking: Function 14

This total is usually cleared automatically about 30 minutes 
after milking.

Run the Function Mode Key Sequence.
To Key In Function14 Use ‘1’ and ‘4’ Keys
Message =’MF’ with the feed total cleared to zero.
Press the Side key to clear the display

Clear Cumulative Feed Total: Function 15

The counter rolls over to zero at 99999

Run the Function Mode Key Sequence.

ATL