Installation and Operation Manual
Document #9620-20-b-mc-16 base tool changer-07
Pinnacle Park
•
1031 Goodworth Drive
•
Apex, NC 27539
•
Tel: 919.772.0115
•
Fax: 919.772.8259
•
www.ati-ia.com
•
Email: [email protected]
B - 11
4.2 Locking Mechanism, Alignment Pins Cleaning and Lubrication
4.2.1
Cleaning and Lubrication of the Locking Mechanism and Alignment
Pins (Master Plate).
1.
The locking mechanism must be in the unlock state before cleaning.
2.
Use a clean rag to thoroughly remove the existing lubricant and debris from
the cam, locking balls, and the alignment pins.
Figure 4.1 —Clean and Lubricate Locking Mechanism and Alignment Pins
3.
Apply a liberal coating of lubricant to the cam, locking balls, and the
alignment pins.
4.2.2
Cleaning the Locking Mechanism and Alignment Pin Bushings (Tool
Plate).
1.
Use a clean rag to thoroughly remove any lubricant and debris from the
engagement surfaces and the alignment holes.
2.
No re-lubrication is necessary on the Tool Plate components.
4.3 Alignment Pin Replacement
1.
Alignment pins can be removed via pliers or by pushing the pins out from the back of the
Master housing.
2.
Install the new alignment pin into the body via an arbor press. Verify the pin is fully
seated into the body. The pin heads should seat fully against the Master body.
3.
Also be sure the diamond head is oriented as shown.