2 - INSTRUCTIONS TO THE INSTALLER
210-0042_libretto_DISC-2018-07_testo_UK.docx
to a heating boiler
Fig. 2.4-09
Solar water heater located on a flat roof
(or on a balcony)
Fig. 2.4-10
Solar water heater mounted on a outer wall
Installation on a vertical wall
In order to make the kind of installation shown in Fig.
2.4-10 efficient, it is necessary
to invert
the cold water
inlet and the hot water outlet.
The
pressure relief and non-return valve
has always
to be fitted on
the cold water inlet
(Fig. 2.4-11).
Fig. 2.4-11
Classical connection
Examples of wrong positioning
Fig. 2.4-12
Solar water heater located in the shade
Fig. 2.4-13
Solar water heater located northwards
Fig. 2.4-14
Solar water heater having a wrong angle
2.5
CONNECTION AND PIPEWORK
Pipes insulation
We suggest to insulate the cold water pipe to the water
heater and the hot water pipe from the water heater,
because they could freeze during the winter time.
The insulation of the tubes can be obtained by using
some covering in expanded elastomer.
Pipe section
The advisable pipe section is 1/2”. However, if the
appliance is a long way from the point where hot water is
used, a 3/4” pipe section is suggested.
Fitting of the pressure relief and non return valve
Содержание DISCOterm
Страница 2: ......
Страница 11: ...2 ISTRUZIONI PER L INSTALLATORE 2 9 TAVOLA RICAMBI ...
Страница 22: ...2 INSTRUCTIONS TO THE INSTALLER 210 0042_libretto_DISC 2018 07_testo_UK docx 2 9 SPARE PARTS ...
Страница 33: ...2 INSTRUCCIONES PARA LA INSTALACION 210 0042_libretto_DISC 2018 07_testo_ES docx 2 8 TABLA DE RECAMBIOS ...
Страница 44: ...2 INSTRUCTIONS POUR L INSTALLATEUR 210 0042_libretto_DISC 2018 07_testo_FR docx 2 8 PIECES DE RECHANGE ...
Страница 47: ......