INSTRUCTIONS FOR THE USER
ENGLISH
p. 4/4
11.MAIN PARTS (FIG_11-1)
POS.
COD.
DESCRIPTION
BL..05 BL..08 BL..12
1
0-0410
fixing-mounting bracket
2
2
2
3
020-0060 heating element cap
1
1
1
4
100-0086 gasket
1
1
1
5
130-0134 MF 1/2" x 30 extension fitting
1
1
1
6
130-0092 pressure relief valve
1
1
1
7
140-0001 cable gland
1
1
1
8
280-0014 heating element 550 w
–
230 V
1
8
280-0015 heating element 850 w
–
230 V
1
8
280-0016 heating element 1250 w
–
230 V
1
9
280-0042 thermostat
1
1
1
10
900-0135 power cable
1
1
1
12. INTERVENTION WATER SAFETY
The electrical heater is equipped with a thermostat which also has safety function: it interrupts the power supply to the electric
heater in case of excessive water temperature. If this occurs, to start again the appliance, it is necessary a manual
intervention (manual reset).
DANGER: THE OPERATION OF THE THERMAL CUT-OUT INDICATES A POSSIBLY DANGEROUS
SITUATION. DO NOT RESET THE THERMAL CUT-OUT UNTIL THE WATER HEATER HAS BEEN
SERVICED BY A QUALIFIED PERSON
For the manual reset operation proceed as follows:
a) disconnect the power supply
b) remove the electrical resistance of the protective cover (FIG_12-1)
c) press reset button positioned on the thermostat (R - FIG_9-1)
d) mount of electrical resistance protective cover (FIG_12-1)
e) restore power supply
13. SAFETY VALVE INTERVENTION
The device is equipped with overpressure safety valve: it protects the tank from possible excessive pressure caused by the
expansion of water during heating. Upon the occurrence of this situation, the water is discharged through the outlet of which
is equipped with the valve.
A small amount of water may escape from this exhaust during the step of heating water.
CONTINUE A LOSS OF WATER FROM THE VALVE MAY INDICATE A PROBLEM WITH HEATING.
FAILURE TO OPERATE THE RELIEF VALVE EASING GEAR AT LEAST ONCE EVERY SIX MONTHS
MAY RESULT IN THE WATER HEATER EXPLODING. CONTINUOUS LEAKAGE OF WATER FROM THE
VALVE MAY INDICATE A PROBLEM WITH THE WATER HEATER
14. MAINTENANCE OF THE APPLIANCE
To make ensure safe operation and extend its life, it is recommended regular inspection (at least annually) by the authorized
customer service or by suitably qualified personnel
Recommended operations during the periodic inspection:
sealing the plumbing fittings
Failure to fully loosen the safety valve
fastening occurs (replace the fastening screws in case they are worn)
electrical system efficiency and electrical grounding
conditions of the power cable (if it is damaged it must be replaced by the manufacturer, authorized technical service
or by qualified personnel in order to avoid risks)
the pressure-relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked
yearly replacement of the anode (FIG_14-1)
To avoid damage caused by frost during the cold season, in the case the boiler is not used, it is necessary to completely
empty the apparatus.
15. WARRANTY
The warranty terms are valid provided that the installation instructions contained in this booklet are followed. The warranty
begins since date of manufacture printed on data label and it has a duration of 36 months. For safety reasons and for the
validity of the guarantee it is mandatory to use only original spare parts.