Manual, F/T Sensor, Data Acquisition (DAQ) Systems
Document #9620-05-DAQ.indd-20
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
• Email:
29
4.2 Installing a DAQ System with Multiple Transducers, IFPSMC Box, and DAQ
Device
1.
Install the data acquisition system hardware (DAQ card, DAQ Device, power supply, and/or cabling) and
its accompanying software following the instructions included with the hardware. Refer to
and
Figure 4.6—Multiple TW Transducers, IFPSMC, and USB DAQ Device System Installation
[5] TW Transducer
(9105-TW-MINI58 Shown)
[1,3a] USB DAQ Device
[1] Power Supply for
USB DAQ Device
[1] USB Cable
[1,6] Laptop running DAQ Software
(9030-05-1001 Software)
[2,4,5] Multi-sensor Interface Box
(9105-IFPSMC-6 Shown)
[2, 3a] DAQ Cables (2)
(9105-C-SH6868EPM-1)
[5] Transducer Connectors
[3a] SCSI Connector
[2] SCSI Connector
Note: [#] indicates the step number
[4] Power Supply Connector
[4] 9105-C-PS-IFPSMC
IFPSMC Power Supply
(Included with Multi-sensor
Interface Box)
[2] Connector 1
to DAQ Card
[2] Connector 0
to DAQ Card
[2] DAQ Cables (2)
(9105-C-SH6868EPM-1)
Rear View of Multi-sensor Interface Box
2.
Connect the 68-pin, D-Type connector on the DAQ cables to the connectors on the back of the
IFPSMC-X box labeled “Connector 0 to DAQ Card” and “Connector 1 to DAQ Card”.Tighten the
jackscrews on the connector to insure a good electrical connection.
NOTICE:
The connections from the SCB-68s to the user’s DAQ device should be made over
shielded twisted pair wiring for noise immunity and to ensure that the shield connections are
properly made. We recommend using differential mode for better noise performance. Use the
appropriate screw terminals and wires gages to correctly pass the sensor signals through.