Mode 

LEDs On 

Function 

Unit operates as Dual 1X6, front panel 
displays and controls Input 1 

Unit operates as Dual 1X6, front panel 
displays and controls Input 2 

1 & Bridge 

Unit operates as 1X12 using Input 1 as 
source; front panel displays and controls 
Input 1 

2 & Bridge 

Unit operates as 1X12 using Input 2 as 
source; front panel displays and controls 
Input 2 

 
DDA212  Series  2  units  retain  their  last  operating  mode  even  if  power  is 
interrupted. 
 
Front Panel Lock 
Press  and  hold  the  FRONT  PANEL  LOCK  button  to  lock  all  the  front  panel 
controls. Press and hold again to unlock. 

 
 

TRANSMITTERS

 

 

The  Frame  sync  (FSYNC),  Serial  Clock  (SCK),  Serial  audio  data  (SDATA), 
Channel status (C), User channel data (U), and data Validity information (VERF) 
are passed directly to the transmitters for reformatting into the AES/EBU  output 
data  stream.  The  transmitters  are  capable  of  operation  from  27  to  192  kHz 
equivalent sample rates. The transmitters operate  in a transparent  mode, which 
allows the transmitter block structure (Channel Status, User  and Validity  bits) to 
be  slaved  to  the  block  structure  of  the  receiver.  In  the  transparent  mode  the 
propagation  delay  of  data  is  less  than  25  nanoseconds  even  at  the  lowest 
sample rate. 

 
 

OUTPUT DRIVERS

 

 

DDA-212XLR  units  are  equipped  with  balanced,  110-ohm,  transformer  coupled 
outputs  and  XLR  type  connectors.  DDA-212BNC  units  use  the  alternative  75-
ohm  unbalanced  outputs  to  BNC  coax  connectors.  The  XLR  outputs  are  in  full 
compliance  with  specification  AES3-1992  and  the  BNC  outputs  are  in 
accordance  with  the  recommendations  of  AES-3id-1995.  XLR  outputs  are 
transformer coupled for ground isolation.

 

 

POWER SUPPLY 

 

Power transformer primary windings are paralleled for 115VAC or wired in series 
for 230VAC. Internal jumpers allow field modification if necessary. See below for 
voltage conversion instructions. 

Содержание DDA-212BNC

Страница 1: ...626 3480 Fax 856 504 0220 sales atiaudio com www audio com Copyright 2011 ATI Audio Inc DDA 212 SERIES 2 Models DDA 212BNC and DDA 212XLR 192kHz AES EBU DIGITAL AUDIO DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL ...

Страница 2: ...sity thus permitting very high resolution signals to be distributed The front panel displays full status of the input signal including Sample rate Word Length Digital Errors and Pro or Consumer Mode DDA 212 Series 2 units contain a unique automatic equalization function that can adjust for extremely long input lines Equalization works independently for each input A Front Panel Lock feature protect...

Страница 3: ...ual input transformers Input termination resistors at 75 ohms for BNC inputs or 110 ohms for XLR inputs can be switched in or out of the circuit with the front panel Input Term switch Inputs should always be terminated unless they are looped thru to another device or DDA input The last device or input should always terminate the line INPUT EQUALIZERS The input signals feed automatic cable equalize...

Страница 4: ...ators Input Fault Illuminates when a digital error is present Inputs 1 and 2 are simultaneously and separately monitored Input Termination Indicates whether the input termination is Off or On Press the INPUT TERM button to toggle the setting Input Sample Rate Indicates the sample rate of the input signal from 32 through 192 kHz Word Length Indicates the Word Length of the input signal from 16 thro...

Страница 5: ...for reformatting into the AES EBU output data stream The transmitters are capable of operation from 27 to 192 kHz equivalent sample rates The transmitters operate in a transparent mode which allows the transmitter block structure Channel Status User and Validity bits to be slaved to the block structure of the receiver In the transparent mode the propagation delay of data is less than 25 nanosecond...

Страница 6: ... to convert a unit wired for 115VAC to 230VAC operation unplug the unit from the power source remove the cover mounting screws and locate the jumpers next to the power transformer Clip the jumpers 1 2 and 3 4 don t unsolder jumper from 2 3 carefully soldering together the free ends of 2 3 previously clipped This procedure is recommended to avoid soldering damage to the multi layer PC board WIRING ...

Страница 7: ...r Inputs 1 or Input 2 Sample Rates Accepts 27kHz to 192kHz Clock With re clocking on regenerated from input signal clock jitter 300 picoseconds peak to peak at 96kHz sample rate With re clocking off input clock is passed directly to outputs OUTPUTS Connectors 12 x XLR male or 12 x BNC chassis mount Levels XLR 4Vp p loaded at 110 ohms BNC 2Vp p loaded at 75 ohms Impedances XLR 110 ohms balanced tra...

Страница 8: ...duct that has been discontinued from its product line with a new product of comparable value and function This warranty shall be void in the event a covered product has been damaged or failure is caused by or attributable to acts of God abuse accident misuse improper or abnormal usage failure to follow instructions improper installation or maintenance alteration or lightning power fluctuations and...

Отзывы: