2.3  AP Network Attachment and Configuration 

AP Network Configuration and Network Boot 
Figure 1 shows an example connection of the AP to a Host PC (HPC).  Follow these steps 
to establish the physical connections: 

 

1.  Plug the serial cable from the AP RS-232 serial interface to the HPC serial COM 

port. 

 
2.  Connect the AP Ethernet port to the HPC Ethernet card through the Ethernet 

hub/switch or an Ethernet crossover cable. An Ethernet switch/hub or crossover 
cable is not included with the Atheros AP Reference Design. 

 
3.  Plug in the 3.3 V power supply adapter (provided by Atheros) to the AP power 

supply connector. 

 

 
 
 
 
 

 

 
 
 
 
 
 
 

 

Figure 1 – Connection Between AP and Host PC

 

 
At this point, the HPC needs the following configuration steps in order to control the AP: 

 

 

 

1.  From the Start menu, choose Settings and open the Network and Dial- up 

Connections window. 

 
2.  Right-click on the Local Area Connection icon, which belongs to the Ethernet 

controller that is connected to the AP and select Properties. 

 

Host PC 

(HPC) 

 

Ethernet Port 

Serial Cable 

Ethernet Cable 

Atheros Access Point 

(AP) 

 

Ethernet 

Hub/Switch 

COM Port 

COM 

Port 

Ethernet 

Port 

Power 

Power 

Supply 

Ethernet Cable 

Содержание AR5BAP-00030

Страница 1: ...Atheros Confidential and Proprietary AP User s Guide Page 1 Subject to change without notice October 2001 FCCID PPD AR5BAP 00030 AP User s Guide Revision October 2001 for Release 1 2...

Страница 2: ...of this document may be reproduced adapted or transmitted in any form or by any means electronic or mechanical for any purpose except as expressly set forth in a written agreement signed by Atheros At...

Страница 3: ...TENTS 4 1 2 SYSTEM REQUIREMENTS 4 2 GETTING TO KNOW THE ATHEROS ACCESS POINT 5 2 1 FRONT VIEW 5 2 2 REAR VIEW 6 2 3 AP NETWORK ATTACHMENT AND CONFIGURATION 8 2 3 1 Booting VxWorks From the Ethernet Co...

Страница 4: ...VxWorks documentation can be obtained through a license agreement with WindRiver Systems See www wrs com for more information about VxWorks licensing The AP contains a small boot executive that allow...

Страница 5: ...nted antennas that rotate 180 for alternative reception positioning and compact packaging Table 1 LED Functionality LED 1 Description Off No Power On Power On and Ready for Operation Blink Power On bu...

Страница 6: ...etected but No Activity Amber Blink 10 Mbps Link Activity blink rate is proportional to activity LED 3 Description Off Wireless Link Disabled Very Slow Blink Looking for Network Association Slow Blink...

Страница 7: ...o a terminal or PC for AP configuration The RJ 45 Ethernet jack is provided for 10 100 Mbps connectivity to a wired Ethernet LAN The Ethernet subsystem is based on a single chip 10 100 Mbps integrated...

Страница 8: ...t crossover cable An Ethernet switch hub or crossover cable is not included with the Atheros AP Reference Design 3 Plug in the 3 3 V power supply adapter provided by Atheros to the AP power supply con...

Страница 9: ...liminary Atheros Confidential and Proprietary AP User s Guide Page 9 Subject to change without notice October 2001 3 Within the Local Area Connection Properties window choose Internet Protocol TCP IP...

Страница 10: ...o change without notice 4 Configure the IP address for the Ethernet connection in the Internet Protocol TCP IP Properties window Click OK to continue and close Local Area Connection Properties Note th...

Страница 11: ...sure there is no other FTP program such as Internet Information Service IIS running on the HPC Double click a ftp exe under the utils folder in the distribution CD to start the FTP server This utilit...

Страница 12: ...idential and Proprietary October 2001 Subject to change without notice 7 Type any name under the Name field in the Connection Description dialog box and click OK 8 Select COM1 or the COM port that is...

Страница 13: ...n HyperTerminal a few seconds after the AP is connected to the power source Press any key to stop the auto boot process and follow Section 3 1 1 to load the VxWorks file over the Ethernet connection o...

Страница 14: ...h Boot from Ethernet Default Setting National Semiconductor boot device tffs0 dp0 processor number 0 0 host name Any value file name fl vxworks Location of VxWorks stored in Host PC inet on ethernet e...

Страница 15: ...xWorks from Flash memory Refer to Appendix B Download Software Image section on page Error Bookmark not defined for CLI commands to load the VxWorks image file to the Flash file system if VxWorks does...

Страница 16: ...in AP web server or by issuing commands through the serial port command line interface CLI 2 4 1 Web Browser The following procedures show the steps to configure the channel frequency and SSID using...

Страница 17: ...ary AP User s Guide Page 17 Subject to change without notice October 2001 2 Click Setup A dialog box appears that requests login authorization When prompted enter the following information to log in L...

Страница 18: ...ly you can also set up Wired Equivalent Privacy WEP for security purposes To set up WEP click WEP and the configuration screen appears Refer to Appendix A for a detailed explanation of the WEP configu...

Страница 19: ...rface The following procedures show the steps required to configure the AP channel frequency and SSID using the command line CLI interface and HyperTerminal 1 After the AP boots and VxWorks loads pres...

Страница 20: ...nd Proprietary October 2001 Subject to change without notice 2 Type set ssid SSID to change the SSID that you wish to specify Type set channel channel to change the IEEE radio channel You must type re...

Страница 21: ...eliminary Atheros Confidential and Proprietary AP User s Guide Page 21 Subject to change without notice October 2001 3 To view CLI command options log in and type help or refer to Appendix B for detai...

Страница 22: ...accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment d...

Отзывы: