60
SL1 DATA LOGGER User Manual Rev. AD
ENGLISH
•
Log frq: specifies the acquisition frequency, if this parameter is set to None, the channel will not
be acquired and will not be available for software analysis .
•
Decimals: specifies the number of decimals (set to 0 if you require whole numbers).
•
Unit: defines the unit of measurement of the channel.
•
Byte Order : this parameter sets the format of the data to one of the following:
Intel: Little Endian byte order
Motorola: Big Endian byte order
NOTE:
this option is only available for channels with a bit length greater than or equal to 16 bits
•
Calibration Type: indicates the type of channel calibration.
•
Calibration Value: specifies the channel calibration values.
•
Channel description: it contains a channel comment that is displayed when the mouse is moved
over the name of the channel.
Configure as necessary and save the setup to a file
or send it to the SL1 Data Logger when finished (see
and
).