background image

TZ-BT05B

--- User Manual V1.7

Содержание TZ-BT05B

Страница 1: ...TZ BT05B User Manual V1 7...

Страница 2: ...es experimental test rooms museums and other temperature testing 2 Applications 1 Refrigerated storage and transportation 2 Archives 3 Experimental test rooms 4 Workshop 5 Museums 6 Pharmaceutical env...

Страница 3: ...60 Temperature detecting range 40 80 Just for the temperature sensor Temperature detecting accuracy 0 5 20 40 1 Other temperature 5 Caution 1 Being close to a metal object will interfere with the sig...

Страница 4: ...oth of the mobile devices and do the settings data transmission recording synchronization send to email Apply the Bluetooth BLE way so you can use Android phone for temperature monitoring Client can d...

Страница 5: ...7 2 2 Enter the device connection page and click Connect After a successful connection the device ID will be displayed on the Devices page indicating that the device has been registered successfully...

Страница 6: ...the menu function and click device to enter the multidevice interface The functions of the device interface are as follow 7 2 1 To view device information The name ID MAC temperature data model and s...

Страница 7: ...Status description of the device in different symbols Temperature normal Temperature alarm including both high and low temperatures 7 2 2 Delete the device Long press to delete the device...

Страница 8: ...arm When the device exceeds the preset upper or lower limit the alarm information will be displayed and the alarm bell will ring Clicking CLOSE to turn off the alarm information and alarm bell 7 3 Dev...

Страница 9: ...t mode of the device will be displayed Four buttons will be displayed at the bottom of the interface Note The device will not update the data in the connection process By default the device will be di...

Страница 10: ...Note The smartphone must have a mailbox APP and login account to send email B Chart...

Страница 11: ...C List 7 4 Configure device After connection when the device does not start recording you can click Configure to set the device...

Страница 12: ...changes with the logging interval 7 4 3 Advanced settings A Access key Must be enable default 000000 7 4 4 Alarms A Low temperature limit 25 B High temperature limit 60 7 4 5 Description You can set...

Страница 13: ...ding 7 5 2 Chart report comparison supporting up to 5 files Check the data file and click Comparison to compare the temperature chart reports of different data files 7 5 3 Delete data file Check the d...

Страница 14: ...Turn on the switch After connection there is firmware upgrade function default 7 6 2 Time Time zone Setting Only for generating reports through the APP 1 System default Time Zone Don t turn on the swi...

Отзывы: