INSTALLATION    ATEX EASYVENT

                                                                                            english 

 

• The equipment in the ATEX area must be operated only by staff qualified in the safety provisions 

concerning this area (EX)  

 

• The panel must be earthed (earth braid).  

 

• Fix the panel with the following type of bolts :  

Bold head H M8<>M10 A2 (DIN933) Lock nut M8<>M10 A4 (DIN985) 

 

• It is advisable to install a safety grid (against falling) for the large horizontally-placed panels (eg. silo 

roof).  

 

• The range of EasyVent (protection system) panels complies with directive 2014/34/EC  

 

• The respect of the Essential Health and Safety Requirements is ensured by compliance with:  

 

EN14491/2006 EN14797/2006 EN14994/2007 

 

The value of Kg max or Kst max are mutually dependent of the minimum volume(V) of the appliance 

to be protected (see cubic law G or D). For example with “ D ” dust: Kst max: 500 bar.m/s - V 7 1m3  

 

- The upper speed limit of pressure raising dp/dt max “ D ” dust is 500bar/s  

- The upper speed limit of pressure raising dp/dt max “ G ” gas is 130bar/s  

 

• Make a periodical inspection visit ( inspection frequence to be defined depending on the site 

conditions), to isolate and problem on the panel caused by the disturbances of the installation to 

secure ( vibration, etc.) or by external influences. During this visit, dust build-up should be cleaned 

with care..  

 

• The explosion discharge should not be operated with products or compounds considered as toxic, 

corrosive, irritating, carcinogenic, teratogenic or mutagenic are liberated. Gas, dust as well as 

combustion products are liable to expose the immediate environment to this type of danger. 

Moreover no particle liable to constitute a danger to human health shoud be liberated.  

 

• The user should make sure the EasyVent panel at the end of its life is dumped properly, and should 

give the components to specialised collection centres following their nature (stainless steel, seals, 

etc.). 

 

 

WARNING:  If the explosion vent panel supplied does not have an integrated frame, a suitable 

frame must be installed.

  

 

 

Maintenance 

In order to be able to detect possible damage in time, regular control inspections must be carried out 

(depending on the operating conditions in the facility).