User Manual

Control Unit Module

Teta

 

MOD Control 1

Product code: PW-108-A

Содержание Teta MOD Control 1

Страница 1: ...POD 051 ENG R02 User Manual Control Unit Module Teta MOD Control 1 Product code PW 108 A...

Страница 2: ...ring Detection and Reduction of gas hazards We invite you to familiarize yourself with our offer on www atestgaz pl Atest Gaz A M Pachole sp j ul Spokojna 3 44 109 Gliwice Poland tel 48 32 238 87 94 f...

Страница 3: ...life How to use this manual The following symbols of optical indicators status are used throughout the document Symbol Interpretation Optical indicator on Optical indicator flashing Optical indicator...

Страница 4: ...le and user interface self test 16 5 4 System view 16 5 5 Devices view 18 5 6 Buzzer internal acoustic warning alarm device 20 5 7 Access to setting options logging in procedure 21 5 8 Control unit me...

Страница 5: ...ns for scope information 26 Table 16 Register numbers of subsequent detectors 27 Table 17 Technical specification 30 Table 18 Method of product s marking 31 List of Figures Figure 1 The construction o...

Страница 6: ...ses to be monitored Identification of hazardous locations in case of gas leaks on the facility area the control unit enables operators to identify locations with possible hazards 1 2 Description of th...

Страница 7: ...ist on the terminals of the control unit It can originate from another system like for an example ventilation system that uses one of the output pins of control unit When performing repair building an...

Страница 8: ...e section 4 1 3 Power supply and control line for devices with Teta interface Power supply and control line for devices with Teta interface 4 EXTERNAL ALARM Binary input see section 4 1 1 D1 External...

Страница 9: ...a digital line for serial transmission RS 485 where the control module acts as a slave device The foregoing functionalities are implemented by readouts of registers located in the area of holding regi...

Страница 10: ...tput activation2 Conditions for the output deactivation R1 ALARM 1 CO NO2 The first threshold for CO NO2 is exceeded or EXTERNAL ALARM is activated The monitored concentration of CO NO2 drops below th...

Страница 11: ...d The first threshold for CO NO2 or LPG NG H2 is exceeded See section 4 1 4 1 R2 GENERAL ALARM AUDIBLE DEVICES The third threshold for CO NO2 or LPG NG H2 is exceeded See section 4 1 4 2 R3 12 V3 VALV...

Страница 12: ...rator depressed the button and the is deactivated in spite of the active alarm The deactivation time expired and the output is reactivated Deactivation time adjustable parameter Figure 6 Operation of...

Страница 13: ...is exceeded CO NO2 Regular operation of CO NO2 detectors concentration of gases is below the established thresholds red 1 blink the first alarm threshold is exceeded red 2 blinks the second alarm thre...

Страница 14: ...sages and enable navigation within on screen menus 5 1 4 Keypad The user interface is operated with the use of a keypad that enables easy and intuitive navigation within various on screen menus In par...

Страница 15: ...pressing of the button user interface test see section 5 3 by simultaneous depressing the buttons s 15 31 User s Manual POD 051 ENG R02 Figure 9 Interface structure 1 Control Unit information 4 Level...

Страница 16: ...ion 5 4 The user interface test i e the foregoing sequence of operations can be initiated at any moment of time from the system keypad see section 5 1 4 It is recommended to launch the aforementioned...

Страница 17: ...g up Special state perform the valve controller test Detector failure Valve controller failure Blinking icon waiting for data transmission Blinking icon waiting for data transmission Alarm threshold 1...

Страница 18: ...ble gases CO carbon monoxide LPG propane butane NO2 nitrogen dioxide NG methane H2 hydrogen Status of the control module The following messages are possible OK regular operation of the control module...

Страница 19: ...xadecimal number with the following meaning of individual bits bit 0 incorrect voltage at the battery terminals bit 1 incorrect valve line resistance bit 2 incorrect device supply voltage s 19 31 User...

Страница 20: ...lence The buzzer can be switched off deactivated for a specific period of time If so the buzzer shall horn no sound even in case when a triggering signal is active However after expiration of the deac...

Страница 21: ...the authorization level is 0 Each user that has physical access to the control module is on the level 0 of authorization rights Should a user want to select an option that requires a higher level of a...

Страница 22: ...ables change of the HMI language see details in section 5 8 2 4 Level 2 password Makes it possible to change password for the password protected level 2 of authorization rights see details in section...

Страница 23: ...transmission rate parity control frame format only for the MODBUS ASCII protocol MODBUS ASCII 1 19200 bauds even E 7 data bits 10 Logout Return to the basic unprotected level 0 of authorization Table...

Страница 24: ...below Figure 11 The Gas Detection System Teta Gas Detailed schematic diagrams in editable format can be downloaded from tetagas atestgaz pl s 24 31 User s Manual POD 051 ENG R02 Operator Control V TOA...

Страница 25: ...nused 1 A2 8 Special status failure UnderRange 2 A3 9 Special status failure SignalToHigh 3 Range exceeded 10 Special status failure SignalToLow 4 Special status warm up 11 Special status other failur...

Страница 26: ...Detector 1 channel 2 momentary concentration 40010 Detector 1 channel 2 medium concentration 40011 Table 14 Memory map Bit 2 Bit 1 Bit 0 Decimal value Description of the bit 0 0 0 0 50 LEL NG 0 0 1 1...

Страница 27: ...ctor 44 40390 Detector 20 40174 Detector 45 40399 Detector 21 40183 Detector 46 40408 Detector 22 40192 Detector 47 40417 Detector 23 40201 Detector 48 40426 Detector 24 40210 Detector 49 40435 Detect...

Страница 28: ...one connector two wires which are not pinched in one cable lug Do not place the cable reserve in the device Bare wires or wires surplus may create a danger of electric shock or equipment damage Do no...

Страница 29: ...enclosure the device does not require any maintenance The external part of the enclosure should be cleaned by means of a soft cloth moistened with water and a bit of a mild detergent 8 7 Utilization T...

Страница 30: ...ommunication protocol GTW port Electric standard Communication protocol Teta Bus RS 485 Modbus ASCII RTU 4800 115200 b s no parity even parity odd parity number of bits 7 8 only for Modbus ASCII Integ...

Страница 31: ...marking Product code Device PW 108 A Control Unit Module Teta MOD Control 1 Table 18 Method of product s marking 11 Appendices 1 DEZG123 ENG EU Declaration of Conformity Teta MOD Control 1 s 31 31 Use...

Страница 32: ...certain voltage limits EN 60335 1 2012 EN 60529 1991 EN 60950 1 2006 in relation to Directive 2011 65 UE on the restriction of the use of certain hazardous substances in electrical and electronic equ...