FG_F6_MODBUS_EN_01 / 2020-06-17
58 / 74
Start cycle command on the ATEQ device
This functionality is only available in Standard access.
Master
Slave
—
Select the program you want to start
—
Make a
Write bit
request at the address
0001h
and force the Start bit to 1
.
On network:
01
05
00
01
FF
00
DD
FA
01
Slave address
05
Function number (Write bit)
00 01
Bit address (Start bit)
FF 00
Force bit to 1
DD FA
CRC
—
Answer to the request (exactly the same as the
request):
On network:
01
05
00
01
FF
00
DD
FA
01
Slave address
05
Function number (Write bit)
00 01
Bit address (Start bit)
FF 00
Force bit to 1
DD FA
CRC