ATEQ, THE ASSURANCE OF A COMPETENT AFTER SALES 

SERVICE

 

„

 

THE ATEQ AFTER SALES SERVICE IS : 

  a team of qualified technicians, 

  a permanent telephone assistance, 

  agencies close to you for faster reaction, 

  a stock of spare parts available immediately, 

  a car fleet for rapid intervention, 

  a commitment to quality ... 

„

 

THE OVERHAUL 

ATEQ carries out the overhaul of your instruments at interesting prices. 
The overhaul corresponds to the maintenance of the instrument (checking, cleaning, replacing of used 
parts) as part of preventive maintenance. 
Preventive maintenance is the best way to guarantee reliability and efficiency. It allows the 
maintenance of a group of instruments in good operational order and prevent eventual break-downs. 

„

 

MAINTENANCE KITS 

The ATEQ After Sales Service proposes, two kits destined for the preventive maintenance of the 
pneumatic circuits of instruments. 

„

 

CALIBRATION 

This may be carried out on site or in our offices. 
 ATEQ is attached to the COFRAC and delivers a certificate following a calibration. 

„

 

TRAINING COURSES 

In the framework of partnership with our customers, ATEQ offers two types of training in order to 
optimise the usage and knowledge of our instruments. They are aimed at different levels of technician: 

  method / control training, 

  maintenance / upkeep training. 

„

 

A TARGETED TECHNICAL DOCUMENTATION 

A number of technical documents are at your disposal to allow you to intervene rapidly in the event 
minor breakdowns: 

  problem sheets describing and offering solutions to the main pneumatic and electronic 

problems, 

  several maintenance manuals. 

„

 

A QUALITY GUARANTEE  

The instruments are guaranteed for parts and labour in our offices: 

  2 years for leak detection equipment, 

  1 year for electrical tests to norms instruments, 

  1 year for the accessories. 

Our After Sales Service is capable of rapidly answering all your needs and queries. 
 

We strongly recommend to send the instrument 

back to ATEQ once a year for re-calibration 

 

Содержание F5800

Страница 1: ...QUICK START MANUAL ATEQ F5800 Photo no contractual Reference MR F5800C U...

Страница 2: ......

Страница 3: ...s and design of this device are subject to be changed without prior notice Edition Revision Reference Date Week Year Chapters up dating First edition MR F5800A U 04 2011 Second edition MR F5800B U 05...

Страница 4: ......

Страница 5: ...ents CALIBRATION This may be carried out on site or in our offices ATEQ is attached to the COFRAC and delivers a certificate following a calibration TRAINING COURSES In the framework of partnership wi...

Страница 6: ......

Страница 7: ...e you complete satisfaction during many long years of operation In order to maximise the life expectancy and reliability of your ATEQ instrument we recommend that you install this instrument on a secu...

Страница 8: ......

Страница 9: ...LE KEYS 8 3 QUICK CONNECTORS 8 STARTING UP AND ADJUSTMENTS 9 1 MAIN MENU 9 2 TEST MENU 9 3 TEST TYPE 10 4 PROGRAMS MANAGEMENT 10 5 PARAMETERS 11 6 START AND STOP A MEASUREMENT CYCLE 12 7 PASSWORD 12 C...

Страница 10: ...OR PIEZO SENSOR TEST PRESSURE 2 MEASUREMENT CHARACTERISTICS 2 1 PRESSURE DROP MEASUREMENT RANGE ACCURACY RESOLUTION Maximum 0 50 Pa 2 5 of the pressure 1 Pa 0 01 Pa 0 500 Pa 2 5 of the pressure 1 Pa 0...

Страница 11: ...ement of a pressure variation between a test part and a reference part TEST PART REFERENCE PART DIFFERENTIAL SENSOR Test without reference measurement of a variation in pressure between a test part an...

Страница 12: ...ATEQ F5800 2 ELECTRICS CONNECTORS 2 1 ON OFF SWITCH The ATEQ F5800 is running under a voltage between 100 and 240 V AC I ON O OFF 2 2 USB CONNECTOR FRONT FACE Allows the connection of various element...

Страница 13: ...15 16 Inputs All or nothing outputs Pin Standard mode Compact mode 1 Input 1 Reset Input 1 Reset INPUTS Activating by 24 V DC Common 24 V 0 3 A maxi 2 Common 24 V Common 24 V 3 Input 2 START Input 2...

Страница 14: ...2 7 J6 CONNECTOR DEVICENET INPUT OPTION 2 1 4 3 5 Reserved for ATEQ network Used for communication with other ATEQ instruments M12 male connector 2 8 J7 CONNECTOR DEVICENET OUPUT OPTION 2 1 4 3 5 Res...

Страница 15: ...OUTPUTS These outputs enable parts to be connected test reference The pressurization output is used for the addition of ATEQ accessories Y valve Inputs Outputs on the rear side of the F5800 Test outpu...

Страница 16: ...the results To scroll the windows drag with your finger from the left to the right or vice versa Note to return directly to the main menu press and hold the Arrow key 2 CYCLE KEYS KEYS FUNCTION KEYS F...

Страница 17: ...rs or configuration menu Special cycles menu access This menu is available by pressing the Settings button 2 TEST MENU The test menu or window is the window displayed during a measurement cycle Menus...

Страница 18: ...o create Then select the LEAK test type The parameters menu is displayed access at each parameter by pressing the corresponding key and by using the numerical keyboard enter the values and validated b...

Страница 19: ...ressure Fill instruction Test pressure that the device will automatically regulate Remind the input pressure must be at least greater than 100 kPa 1 bar of the test pressure Reject unit Leak unit disp...

Страница 20: ...The password gives or locks access to the device The default identifier is admin and its password is admin The administrator can select different rights following the user See the User rights menu We...

Страница 21: ...n the test parameters Functions menu of each program 1 2 ADDITIONAL FUNCTION LIST Name Program sequence Units Filter Automatic Connector Calibration check by volume Transient Attenuation ATR Pre Fill...

Страница 22: ...by volume with a pass part Learning Check these cycles allow running a learn or a check cycle or both in Pascal or Pascal sec calibrate mode with a master leak ATR Learning cycle to enter ATR paramet...

Страница 23: ...CCESSORIES IN OPTION Master leaks the master leaks are used to check the device calibration Micrometer valve and Leak Calibrator CDF Automatic connectors with expandable seals Filtration kit Singles r...

Страница 24: ...error Sealed component error Sealed components large leak error Auto test fault 2 IN CASE OF OPERATION DOUBT If a test machine begins to detect too many fail parts more than three consecutively it is...

Страница 25: ...15 Maximum fill 11 Measurement cycle 3 Measurements characteristics 2 Minimum fill 11 N Navigation 8 O Operation fault 16 P Password 12 Pneumatic supply 7 Pneumatics connectors 7 Pneumatics outputs 7...

Страница 26: ...This document is the exclusive property of ATEQ It may not be communicated reproduced or used without prior consent...

Отзывы: