3. Operation
15
CE800R (Remote Unit):
USB Mass Storage
Both the CE800L and the CE800R have a built-in USB port that complies with
the USB Mass Storage specification and supports USB Mass Storage
compliant flash drives, allowing easy and convenient file transfer.
When you plug a USB Mass Storage complaint flash drive into either unit’s
USB port, it shows up as a removable drive on the computer.
As a security measure, to help prevent unauthorized file transfers, if a flash
drive is plugged into the USB port of the Remote unit, the OSD login screen
comes up (see page 16). The operator must log in with a valid username and
password before being able to continue.
LED
Status
Indication
Remote
On
Remote Mode is in effect. The Remote console has
keyboard and mouse input control.
Off
Local Mode is in effect. The Local console has
keyboard and mouse input control.
Flashing
Auto Mode is in effect. Neither console has keyboard
and mouse input control. The first console to establish
keyboard or mouse input takes control. Following this,
if there is no input for five seconds, the CE800 goes
back to Auto Mode.
Link
On
The CE800R is connected to the CE800L.
Off
The CE800R is not connected to the CE800L.
Compensation
Flashing
A picture compensation button has been pushed (+ or
–) and the CE800 is adjusting the gain.
Steady
Gain adjustment has been completed and saved.