![Atek INC 210 Series Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/atek/inc-210-series/inc-210-series_user-manual_2997114003.webp)
KK-INC.006 18.01.19 Rev No:1
3
Supply Voltage
4-20 mA : 12 … 24 VDC
0-10 VDC: 15 … 24 VDC
Protection Class
IP67
*Measurement
Range
0⁰ … 360⁰
Operating Temperature
- 30°C … +70°C
Relative Humudity
%10 … %90
*Output Signals
Analog 4-20 mA or 0.1-10 VDC
Optional Redundant Output
Weight
~250 gr
Resolution
12 bit
Body Material
Aluminium
Accuracy
±0,1⁰
*Electrical Connection
M12 5 pin (male) socket or cable output
Note:
The specifications specified by (*) vary depending on the model selected. The detailed code table for product selection is shown on page 4.
Product Description
INC 210
Angle Sensor
User Manual
1 pcs.
TECHNICAL SPECIFICATIONS
PRODUCT CODE TABLE
BOX CONTENTS
Supply Voltage
(1)
PP:
12…24VDC /
15…24VDC
INC 210
X
XX
XX
XX
XXX
XX
XX
XX
Sensor Type
A :
Angle
Model
INC 210
Number of axes
01:
Single axis
Output Signals
V:
0-10 VDC
A:
4-20 mA
Electrical Connection
(3)
3M
: 3m cable
5M
: 5m cable
10M
: 10m cable
S13F
: M12 5 pin female socket
S13M
: M12 5 pin male socket
S13FM
: M12 5 pin M12 5 pin
male socket (redundant models)
Measurement Range
(2)
360:
0-360°
180:
0-180°
Output Signal Direction
CW:
Clockwise
CCW:
Counter-Clockwise
Output Type
No code :
Single Output
Dual
:
Redundant
output
(1) The supply voltage is 12…24VDC for 4-20 mA output models, and 15…24VDC for 0-10 VDC output models.
(2) Optionally, different measurement values between 0-360° can be requested. You should specify your non-standard measurement
value at the order stage.
(3) The product can be requested with cable or socket.
As standard;
For single output models, 1 pcs M12 5 pin male socket (S13M) is used.
For redundant models, 1 pcs M12 5 pin 1 pcs M12 5 pin male socket (S13FM) is used.
However, different socket combinations may be requested as in the examples below.
Please contact us for any other socket model other than M12.
Sample Code 1:
INC210-A-01-360-PP-A-CW-S13F
INC 210 series, angle, single axis, 0-360° measurement, 12-24VDC supply, current output, clockwise, 1 pcs M12 5 pin female soket,
single output
Sample Code 2:
INC210-A-01-180-PP-V-CCW-S13FM-DUAL
INC 210 series, angle, single axis, 0-180° measurement, 15-24VDC m, volt output, counter-clockwise, 1 pcs M12 5 pin 1 pcs
M12 5 pin male socket, redundant output