Line A/B Open
Line A/B Short
Line A/B Bad Im pedance
3.1.9.1.6 Amplifier Line Leakage Error
An electricity leakage between the IDA8C/S and the speaker is detected. The measurement of speaker
lines has short-circuit fault due to the + speaker line is connected to ground wire, and - is connected to
ground wire.
Indication:
LED Indicator:
When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
o
Zone Fault LEDs on the front panel of the IDA8C/S.
Log:
The text messages display on the touch screen of the IDA8C as follows:
"AMP Line Leakage Error".