IDA8 Global-Net User Manual
486
© 2017, ATEÏS, member of PAX ProAV Group
Note: Please check and set the number of
paging source from [
window chapter and make sure the number you
set is correctly distributed.
5.17.2 Local Net Input
This component transfers the audio signals over Ateis Net. The signal goes into a channel of a Net Output
component and retrieves from the output with the same channel or any other Net Input component(the
signal path is one to many relationship). There are up to 48 channels available to carry signals, and the
number of channels will be distributed based on the number of channels you set on [
The diagram below shows a example using IDA8
devices to show the configuration of the Net
Input and Net Output components.
In Device editing window, create an IDA8C and
an IDA8SAB. Connect the NB to NA pins to
create a Ateis Net system.
In the DSP design window of IDA8C, it utilizes
the Net Input/Output channel 1 to transport
audio signal from Input A channel in IDA8C to
Output C channel in IDA8SAB.
Note: Please check and set the number of
paging source from [
window chapter and make sure the number you
set is correctly distributed.
5.18
Net Output
5.18.1 Global Net Output
This component transfers audio signals over Ateis Net. It must work with Net Input. Please go to
.