52
© 2019, ATEÏS, member of PAX ProAV Group
3.14
EVAC inputs
The 9 evac inputs on BTQ-VM8/SG8/SL8 and 4 on
BTQ-VM4 can let the third party systems to signal
the BOUTIQUE system for triggering events, start
evac paging or message announcement. The
settings of
requires to be set on web
browser.
The EVAC inputs have a higher priority than
the Logic inputs.
Each channel supports 3 modes:
Monitored contact mode: The system can
monitor the evac input and detect faults (4
status: on, off, open and short).
Monitored contact mode
Disable: The cables which connect to
evacuation input will not be monitored (faults
will not be detected).
Voltage mode: Trigger the input by a voltage
change (OPEN/CLOSE) with an external
24VDC source provided by external devices.
The cable is not monitored in this mode.
3.15
Mic/Line input with VOX (XLR)
The BTQ-VM4/VM8 controller has 1 Mic/
Line balanced XLR input with voice-
activated (VOX).
When connecting the MIC/Line input,
please switch ''ON'' on [VOX] setting, and
adjust the mic volume by the gain knob.
The BTQ-VM4/VM8 also provides 48VDC
phantom power for MIC/Line input. If the
MIC/Line input requires phantom power
supply, set the [Phantom Power] switch in
ON position. If the microphone does not
applicable for phantom power supply, leave
the switch in OFF position.
3.16
BGM inputs (RCA)
The main controller has 2 BGM inputs.
Each BGM input has a double cinch
socket which converts stereo to mono.
Connect the background music source
on these cinch input such as CD player
or tuner.
Input
Source
CD/Tuner
CD or tuner
AUX
Auxiliary source