5
2.4.
Dimensions
2.5.
Electric And Pneumatic Control Panel
There is an electrical panel at the top, the power supply must be turned off by the authorized electrician and should be
checked with the diagram on the cover in case of a problem.
In the lower part there is a pneumatic panel and the coolant receptacle. It must be opened by authorized
personnel and filled with suitable coolant. The coolant has to be water based.
The panel door must be closed and locked during operation. In the service work carried out for
maintenance and possible defects;
CLOSE ELECTRICAL AND PNEUMATIC POWER RESOURCES.
Set the air pressure between
6-8 bars. The manometer is
read as air pressure bar. If
the reading on the pressure gauge is less than or
equal to the desired pressure, turn the air pressure
adjustment switch to the right or left to adjust the
pressure to 6-8 bar
.
The conditioner unit collects the water contained in the air system into the collection container so as not to damage the
pneumatic system components. Periodically (on the working day) drain the water by pressing or opening the button under
the conditioning cylinder deposit to drain the collected water
.
2.6.
Electric Circuit Inputs – Outputs
INPUTS
OUTPUTS
Start_Button
P00000
Servo_1_Pals_Infeed
P00040
Stop_Button
P00001
Servo_2_Pals_Saw
P00041
Emergency_Stop
P00002
Servo_1_Dir
P00042
Pressure Adjustment
Knob
Manometer
Air Pressure and
Water Discharge
Oil Storage
Oil Additional
Stopper