7.
Remote Operation
Using the external PC, type in the system’s IP Address into a web browser.
(Mozilla Firefox or Google Chrome recommended).
For example: https://192.168.1.50 -- Note that this is a security enabled webpage
and HTTPS:// is required.
The System Logon screen will appear. For full administrator access, logon
using username “ADMIN” and password “admin”. Click “proceed anyway”
when prompted for Security Certificate.
The “Dashboard” web page will be displayed, which contains some basic
system information. Switch from local to remote mode by clicking on the
“Remote” button. You will again be prompted for the administrator password.
From here, you can navigate to the various web pages which allows you to set
operational modes and settings and to view detailed system diagnostics.
6.
Set IP Address (Factory Set at 192.168.1.50)
On the front panel LCD, touch the IP Address entry box.
A keyboard box will appear, allowing you to enter your IP address,
subnet mask, and gateway in the following format: IP address..
subnetmask.. gateway.
For example: 192.168.1.50..255.255.255.0..192.168.1.1
Note: A stylus pen works best for keyboard entries.
Save settings ( green tab next to IP window) and recycle the power
(turn breaker off, then back on). The system will come back online
and is now ready to transmit in ALC mode at full output power.
Quick Start Guide/Model 2162
READ AND FOLLOW THE OPERATING MANUAL BEFORE TRANSMITTING RF POWER
Factory default Configuration:
1.
Local Control (front panel)
2.
Standby
3.
ALC Mode
4.
Power Output set
to 60 dBm
What’s included in the box?
1. 2162 Power Amplifier System
2. AC Power Cable
3. Operating Manual, Doc #
0001-2162
4. The Quick Start Guide