background image

 
Storing 

z

 

When not using spray gun, turn the fluid adjustment knob counter-clockwise to open which will reduce 

spring tension on needle fluid tip. 

z

 Spray 

gun 

MUST BE

 well cleaned and lightly lubricated. 

 

Troubleshooting  

 

Symptom 

Problems 

Solution

 

Fluttering or 

spitting  

 

 

1.  Material level too low. 

2.  Container tipped too far. 

3.  Loose fluid inlet connection. 

4.  Loose or damaged fluid tip/seat. 

5.  Dry or loose fluid needle packing nut. 

6. Air 

vent 

clogged 

1. Add 

material 

into 

container. 

2. Hold 

more 

upright. 

3. Tighten. 

4. Adjust 

or 

replace. 

5.  Lubricate and or tighten. 

6.  Clear vent hole. 

Pattern is arched. 

 

 

1.  Worn or loose Fluid nozzle. 

2.  Material buildup on Air cap. 

1.  Tighten or replace Fluid nozzle. 

2. Remove 

obstructions 

from 

holes, 

but don’t use metal objects to clean it. 

Pattern is not                     

evenly spread.

       

 

 

1.  Material buildup on Air cap. 

2.  Fluid nozzle dirty or worn. 

1.  Clean or replace Air cap. 

2.  Clean or replace Fluid nozzle. 

The center of pattern is 
too narrow. 

 

 

1.  Material too thin. 

2.  Atomization air pressure too high. 

1. Regulate 

material 

viscosity. 

2. Reduce 

air 

pressure. 

Pattern width of fan 

shape is too narrow 

 

1.  Material too thick. 

2.  Atomization air pressure too low. 

1. Regulate 

material 

viscosity. 

2.  Increase air pressure. 

 

Air leaking from air cap 

without pulling trigger   

 

 

1. 

Sticking air valve stem 

2. 

Contaminate on air valve or seat 

3. 

Worn or damaged air valve or seat 

4. 

Broken air valve spring 

5. 

Bent valve stem 

1. Lubricate 

2. Clean 

3. Replace 

4. Replace 

5. Replace 

Fluid leaking from 

packing nut 

 

1.  Packing nut loose 

2.  Packing worn or dry 

1.  Tighten, but do not restrict needle 

2.  Replace or lubricate (use non-silicone 

oil) 

Excessive overspray 

 

1.  Too high atomization pressure 

2.  Too far from work surface 

3.  Improper stroking (arcing, gun motion 

too fast) 

1. Reduce 

pressure 

2.  Adjust to proper distance 

3.  Move at moderate pace, parallel to 

surface. 

Will not spray 

 

1. No 

pressure 

at 

gun 

2.  Fluid control not open enough 

3.  Fluid too heavy 

1.  Check air lines 

2.  Open fluid control 

3.  Thin fluid or change to pressure feed 

system. 

 

 