      his chapter covers brief, introductory information, You will find: 

 

Safety precautions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Safety  

DANGER 

 

Engines produce carbon monoxide which 
is odorless, causes slower reaction time, 
and can lead to serious injury. When the 
engine is operating, keep service areas 
WELL VENTILATED or attach the vehicle 
exhaust system to the shop exhaust 
removal system. 

 
 

 

Set the parking brake and block the 
wheels before testing or repairing the 
vehicle. It is especially important to block 
the wheels on front-wheel drive vehicles; 
the parking brake does not hold the drive 
wheels. 

 

 

Wear an eye shield when testing or 
repairing vehicles. 

 
Exceeding the limits of this meter is 
dangerous. This will expose you to serious 
or possibly fatal injury. Carefully read and 
understand the cautions and the 
specification limits of this meter. 

 

Voltage between any terminal and ground 
must not exceed 600V DC or 600V AC. 

 

 

Use caution when measuring voltage above 25V DC or 25V AC. 

 

 

Circuit tested must be protected by a 20A fuse or circuit breaker. 

 

 

Do not use the meter if it has been damaged. 

 

 

Do not use the test leads if the insulation is damaged or if metal 
is exposed. 

Содержание 5585

Страница 1: ...2 Hz ms CYL Button 9 Data Hold Backlight Button 9 Peak Hold 10 Meter Functions Voltage V 12 Resistance 13 Diode Check 14 Capacitance CAP 15 Audible Continuity 16 AC or DC Current A 17 Temperature 0 F...

Страница 2: ...lock the wheels on front wheel drive vehicles the parking brake does not hold the drive wheels Wear an eye shield when testing or repairing vehicles Exceeding the limits of this meter is dangerous Thi...

Страница 3: ...the 20A terminals are protected by fuses To avoid possible injury or damage use only in circuits limited to 400mA or 20A for 30 seconds See also Fuse Replacement Safety Cont d IMPORTANT To maintain ac...

Страница 4: ...5 6 Notes Getting Started his chapter will help you get started It describes the basic functions of the Meter...

Страница 5: ...OFF 4 Volts Terminal The Red test lead is used to measure Amps Volts Ohms TEMP Hz RPM Cap mS and Dwell The Black test lead is used in the Common COM terminal for all tests LCD DISPLAY SYMBOLS AND ANNU...

Страница 6: ...the indicator The indication of HOLD will appear in the display 2 Press the DATA HOLD button again to return to normal operation Peak Hold The Peak Hold function captures the peak AC or DC voltage or...

Страница 7: ...to turn the backlighting ON 2 Press the BACKLIGHT button again to turn the backlighting OFF Meter Functions Voltage V Select the Volts V range with the rotary switch The meter will automatically selec...

Страница 8: ...tions Diode Check IMPORTANT Turn the power OFF to the test circuit Select the Diode Check function with the rotary switch and mode button Insert Black lead in COM terminal Red lead in V RPM terminal T...

Страница 9: ...recise the bar graph is instead used to display the time required to accomplish the measurement 2 In order to obtain an accurate reading a capacitor must be discharged before measurement begins The me...

Страница 10: ...power source Connect The Red probe to the side of the circuit closest to the power source The Black probe to the side of the circuit to ground Turn the power ON and test Meter Functions Temperature 0...

Страница 11: ...d lead in V RPM terminal Connect the Black test probe to ground Connect the Red test probe to the signal out wire of the sensor to be tested Meter Functions Dwell Select the DWELL function with the ro...

Страница 12: ...Pulse Width ms PERIOD Period Pulse Width is the length of time an actuator is energized For example fuel injectors are activated by an electronic pulse from the Engine Control Module ECM This pulse ge...

Страница 13: ...switch OR Select the 10RPM range with the rotary switch 1 000 to 12 000 RPM Multiply the displayed reading by ten to get actual RPM Press STROKE DIS button to select through RPM for 4 stroke RPM for 2...

Страница 14: ...oC to 60 oC 4 oF to 140 oF at 80 relative humidity For inside use max height 2000m Pollution degree 2 Power One 9V battery NEDA 1604 IEC 6F22 Dimensions 182 H x 82 W x55 D mm Weight Approx 375g Electr...

Страница 15: ...t 400mA dc or 400mA ac rms on uA mA ranges 20A dc or ac rms on 20A range Resistance Range Resolution Accuracy 400 0 0 1 1 2 of rdg 4 dgts 4 000k 1 1 0 of rdg 2 dgts 40 00k 10 400 0k 100 4 000M 1k 1 2...

Страница 16: ...s from any source of voltage before removing the battery door 1 Disconnect the test leads from the meter 2 Open the battery door by loosening the screw using a Phillips head screwdriver 3 Insert the b...

Страница 17: ...fuse Open circuit in a test lead frayed or broken wire 4 Meter readings do not change Hold feature is still toggled ON WARRANTY INFORMATION This product is warranted to be free of defects for one year...