Indicates a temporary or permanent amplifier fault. The Fault
LED
will illuminate if there is a
DC
fault on the amplifier or if the thermal limit of the
heatsink is reached. In the rare case that the Fault
LED
illuminates, the subwoofer should be switched off. Ensure the subwoofer heatsink has
adequate ventilation and after
45
minutes switch it back on. If the Fault
LED
remains illuminated the amplifier is registering a fault which should be
investigated by an approved technician. Please contact your
ATC
dealer or distributor, details can be found at www.atc.audio. If the Fault
LED
is no
longer illuminated, the amplifier had shut down safely due to reaching high temperatures. Please reduce the system listening level, subwoofer Level
or improve amplifier ventilation and continue to use the subwoofer.
Indicates operational state. The Studio Control Subwoofer has two
LED
’s mounted in the front facing badge (Diagram 6).
The
LED
to the left is a Bi-Colour Green/Red
LED
. When Green the subwoofer is powered ON, when Red, the subwoofer amplifier is limiting,
please reduce the listening level. Persistent and/or continuously illumination of the Red
LED
can result in damage to the amplifier or driver.
The
LED
to the right is not lit when the subwoofer is operational and will illuminate Blue when the subwoofer is Muted via an external footswitch,
see Section 5.6.
SECTION FIVE
DIA
G
R
A
M
6
F a u l t
F r o n t P a n e l D i s p l a y
5.7
5.8
POWER / LIMIT
MUTE
ACOUSTIC ENGINEERS
PROFESSIONAL
SERIES
SUBWOOFER
MADE IN ENGLAND
Acoustic Transducer Co. Is a trading name and
Is the registered Trade Mark of Loudspeaker Technology Ltd.
R
STUDIO SUB BADGE ARTWORK revA
04-12-20
PANEL ANODISED BLACK. TEXT AND LOGO
TO APPEAR OFF WHITE AS SAMPLED.
LASER ETCHING SHOWN ABOVE IN
BLACK.
DOTTED LINES DENOTE PANEL EXTENTS,
DO NOT PRINT.
REVISION NOTES:
04-12-20 - revA- NEW PART NUMBER, NO
CHANGES. WAS “SCS70 BADGE revC”
90.00 mm