Step 3: Enter Gateway IP address

Step 4: Enter Primary DNS IP address

Step 5: click Update button

4.6 DHCP

Host Name (Optional): default NETUART, maximum length 15
characters
If there is a DHCP Server existing in your network environment or
you subscribe a CABLE service from your ISP, you can set IP
configuration to DHCP to get a dynamic IP address. The Host Name
is an optional item, depending on your DHCP Server setting.

5.0 System Status

This screen shows the ATC-1000’s current status. All of the information

provided is read-only.

Kernel Version: the installed version of the kernel.

MAC Address: At present the device MAC Address

Nickname: the product model name of NetUART

5.1 Load default setting

Allow Users to reset the ATC-1000 to return the initial value, but the MAC

Address will not be updated.

5.2 Telnet

Telnet connection setting:

Telnet Server/Client: Currently used to determine the device is to the Telnet

Server or Client.

If the Server, show this connection have to wait for the other side of the Port,

if the Client, show that external connections to the Port

Remote Server IP Address: When the Client, to be connected the other side

of the server IP Address.

5.3 Operation mode

The ATC-1000 support four operation mode: TCP Server, TCP Client,
UDP Server and UDP Client. These modes are listed in the Web
page for the Operation Mode setting. Each setup screen and
available features will differ depending on what kind of operation
mode you select. Default is TCP Server.

5.4

TCP Server

Port Number: default 23, range to 65535

If your device is acted as passive to accept commands from remote and the

data be guaranteed to be received by peer is your concern, then you can set

ATC-1000 as TCP Server. Be sure the value of item Port Number is same

as your remote control application using.

Client mode inactive timeout

(minutes): default 20 (

0=Disable)

If you want to keep the connection between ATC-1000 and your remote

control application always on, then set the value of item

Client mode

inactive timeout

(minutes) to 0, otherwise, when the inactive time of no

any traffic on line reach the setting value, ATC-1000 will terminate this

connection.

5.5 TCP Client

Remote Connection Port Number: default 23, range to 65535

Remote Host IP Address: default 210.200.181.102

If your device is acted as active to report real-time status to remote and the

data be guaranteed to be received by peer is your concern, then you can set

ATC-1000 as TCP Client. Be sure the value of item Remote Connection

Port Number is same as your remote control application using and set the

correct value of Remote Host IP Address.

5.6 UDP Server

Local Port Number: default 21, range to 65535
If your device is acted as passive to accept commands from remote
and the data be guaranteed to be received by peer is not your
concern, then you can set ATC-1000 as UDP Server. Be sure the
value of item Local Port Number is same as your remote control
application using.

5.7 UDP Client

Remote Connection Port Number: default 21, range to 65535

Remote Host IP Address: default 192.168.2.2

If your device is acted as active to report real-time status to remote
and the data be guaranteed to be received by peer is not your
concern, then you can set ATC-1000 as TCP Client. Be sure the
value of item Remote Connection Port Number is same as your
remote control application using and set the correct value of Remote
Host IP Address
.