Serial-to-Ethernet Device Servers
Copyright © 2014 Reserved by ATC Technology, All Rights Reserved
Step 3: Enter Gateway IP address
Step 4: Enter Primary DNS IP address
Step 5: click Update button
4.6 DHCP
Host Name (Optional): default NETUART, maximum length 15
characters
If there is a DHCP Server existing in your network environment or
you subscribe a CABLE service from your ISP, you can set IP
configuration to DHCP to get a dynamic IP address. The Host Name
is an optional item, depending on your DHCP Server setting.
5.0 System Status
This screen shows the ATC-1000’s current status. All of the information
provided is read-only.
Kernel Version: the installed version of the kernel.
MAC Address: At present the device MAC Address
Nickname: the product model name of NetUART
5.1 Load default setting
Allow Users to reset the ATC-1000 to return the initial value, but the MAC
Address will not be updated.
5.2 Telnet
Telnet connection setting:
Telnet Server/Client: Currently used to determine the device is to the Telnet
Server or Client.
If the Server, show this connection have to wait for the other side of the Port,
if the Client, show that external connections to the Port
Remote Server IP Address: When the Client, to be connected the other side
of the server IP Address.
5.3 Operation mode
The ATC-1000 support four operation mode: TCP Server, TCP Client,
UDP Server and UDP Client. These modes are listed in the Web
page for the Operation Mode setting. Each setup screen and
available features will differ depending on what kind of operation
mode you select. Default is TCP Server.
5.4
TCP Server
Port Number: default 23, range 0 to 65535
If your device is acted as passive to accept commands from remote and the
data be guaranteed to be received by peer is your concern, then you can set
ATC-1000 as TCP Server. Be sure the value of item Port Number is same
as your remote control application using.
Client mode inactive timeout
(minutes): default 20 (
0=Disable)
If you want to keep the connection between ATC-1000 and your remote
control application always on, then set the value of item
Client mode
inactive timeout
(minutes) to 0, otherwise, when the inactive time of no
any traffic on line reach the setting value, ATC-1000 will terminate this
connection.
5.5 TCP Client
Remote Connection Port Number: default 23, range 0 to 65535
Remote Host IP Address: default 210.200.181.102
If your device is acted as active to report real-time status to remote and the
data be guaranteed to be received by peer is your concern, then you can set
ATC-1000 as TCP Client. Be sure the value of item Remote Connection
Port Number is same as your remote control application using and set the
correct value of Remote Host IP Address.
5.6 UDP Server
Local Port Number: default 21, range 0 to 65535
If your device is acted as passive to accept commands from remote
and the data be guaranteed to be received by peer is not your
concern, then you can set ATC-1000 as UDP Server. Be sure the
value of item Local Port Number is same as your remote control
application using.
5.7 UDP Client
Remote Connection Port Number: default 21, range 0 to 65535
Remote Host IP Address: default 192.168.2.2
If your device is acted as active to report real-time status to remote
and the data be guaranteed to be received by peer is not your
concern, then you can set ATC-1000 as TCP Client. Be sure the
value of item Remote Connection Port Number is same as your
remote control application using and set the correct value of Remote
Host IP Address.