ATC Almeria 
DPH1500T Скачать руководство пользователя страница 9

  

  

 

 

Setting the temperatures 

There are two adjustable temperature settings that can be individually set. These set 

points are used for the “on” and “off” settings 
for the heater.  

The  Comfort setting is used for the room 
temperature that you want to maintain when 
the heater is 

on

.  

The Economy setting is for when the heater is 

off

The Factory setting for Comfort is 21°C and the factory setting for Economy is 
7°C,  both of these settings are reset to the factory default if  you reset the 

heater.    To indicate which temperature setting is active when the heater is in 

program run mode there is either a C or and E shown beside the Weekday  

Heating Indicator  

In any of the operation modes the Almeria heater will display the indicator shown on 

the left on the bottom of the display  to indicate that that the elements are 
turned on. 

Program Menu 

The Almeria heater is equipped with a 24 hour 7 day timeclock 
with  4 time periods per day.  Each time period can be 
programmed with an  hour and minute time setting. Each 
entered  setting is for comfort temperature, time periods 
outside of the set times are maintained at the economy 
setting.  
The Program menu has 4 settings, Set 
Program,  Copy Program, View Program 
and  Program Run. In order to run a 

program that you have saved highlight the Program Run 
option and touch enter. The heater will return to the main 
program run screen and show the current set point, program 
and if the Almeria is heating or not.  
 

 

Содержание Almeria DPH1500T

Страница 1: ...DPH1000T DPH1500T DPH2000T ATC Almeria Digital Panel Heater 3 Year Warranty INSTALLATION OPERATION MAINTENANCE MANUAL Class I IP 20...

Страница 2: ...or lack of experience or required knowledge provided that they are under supervision or after they have been instructed relating to the safe use and have understood the potential dangers Children sho...

Страница 3: ...ATION NOTES The installation should always be carried out by a qualified electrician or a competent person in accordance with the current electrical standards HD 384 CENELEC for Mainland Europe IEC 60...

Страница 4: ...the bottom of the heater above floor level The Heater must not be located either directly below or in front of a socket outlet The heater must be installed so as to prevent any control switches being...

Страница 5: ...disconnect the wall bracket from the back of the heater Mark the wall according to the dimensions given below for the heater of your correct size Drill the wall and insert the plastic wall anchors int...

Страница 6: ...ack of the heater and tightened after the heater is mounted on the wall see below NOTES Prior to drilling the wall ensure there are no cables or pipes within the wall and ensure that the mounting scre...

Страница 7: ...he correct information is showing touch enter to save Daylight Savings DST Mode The daylight savings feature will automatically adjust the time of your heater each year on the last Sunday in March and...

Страница 8: ...ater these correspond to the 3 operating modes Standby Manual and Program In both standby and manual mode you can boost the heater to the comfort setting for a period of 1 or 2 hours To activate the b...

Страница 9: ...the Weekday Heating Indicator In any of the operation modes the Almeria heater will display the indicator shown on the left on the bottom of the display to indicate that that the elements are turned o...

Страница 10: ...me When you move to the off time and select enter the heater will default to the following minute after the previous on time E g If you had entered 07 00 the off time automatically changes to 07 01 Th...

Страница 11: ...on screen Key lock The Almeria heater has a built in lock screen to prevent any accidental changes to the heater The Keylock is activated by holding the keys down for 5 seconds When the heater is lock...

Страница 12: ...nd premature element failure To clean the outside of the appliance wipe off dirt with a damp cloth Do not use any aggressive cleaning agents Do not immerse the heater in water or any other liquids 6 T...

Страница 13: ...mption At nominal heat output elmax N A kW At minimum heat output elmin N A kW In standby mode elSB 0 05 kW Type of heat output room temperature control Electronic room temperature control plus week t...

Страница 14: ...ling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal 9 GUARANTEE You...

Страница 15: ...NOTES Head Office Energy Showrooms ATC House Broomhill Drive Tallaght Dublin 24 Ireland Tel 353 0 1 467 8301 UK Tel 44 0 203 564 9164 Email sales atc ie www atc ie...

Отзывы: