Potential-free Contact
The control system has a contact, which is designed as
changeover contact, e.g. for the connection of an external signal
transmitter. To connect the contact please carefully break out the
pre-stamping in the casing and lead the cable through a suitable
M16 threaded connection in order to maintain the degree of
protection of the casing.
The contact functions as break contact (opener) to the terminals
11 and 12 (with activated fault indication).
11 - C (common): common lead
12 - NC (normally closed): break contact
14 - NO (normally open): closing contact
Configuration of the Connection Socket
(Plan view casing exterior)
Pin
plug
Colour
Solder
joint
AC/ DC
Function
CLASSIC/PRI
MO
Function
BASIC
1 Blue
N
230V
AC
Neutral lead
(Mains)
Neutral lead
(Mains)
2 Black T1.3
230V
AC
Phase aerator Phase aerator
3 Brown T1.1
230V
AC
Phase sludge
pump
Neutral clarified
water pump
4 Violet T1.2
230V
AC
Phase clarified
water pump
Phase clarified
water pump
5
Orange
IN1
12V DC Float 12V feed Float 12V feed
6
White
(blue)
N
12V DC Float return
Float return
7
Yellow/
green
PE PE
PE earth
conductor
PE earth
conductor
Pin 4
Pin 5
Pin 6
Pin 1
Pin 2
Pin 3
Pin 7