B. BASIC STRUCTURE
1.
Power-Supply
Primary - AC 50/60Hz 100V, 115 V, 220 V or 240 V
Transformer for each AC voltage is selected at the
factory.
Note: There are four types of transformer. A
selection of voltage is made at the
factory-set in accordance with the customer's
requirements.
Secondary - DC 5 Volt for TTL Logics.
DC 19 Volt for Printer Mechanism.
2.
CPU and Control Circuit Block
Main Control Board with CPU, ATARI SIO Interface
Board and Operation Key Board.
3.
Printer Mechanism
Printer Head, Head Carriage Mechanism, Paper Feed
with Tractor Mechanism and Ribbon Driver Mechanism
are in unit.
The Printer head is replaceable but disassembling of
the other parts of unit at the field is not
recommended for repair. In case of the printer
mechanism is defective, the whole printer mechanism
unit should be replaced, and the defective one be
sent back to the factory.
Figure 4. General Blocks of Structure
-3-
Содержание XMM801
Страница 1: ......
Страница 2: ...SERVICE MANUAL PERIPHERAL PRINTER XMM 801...
Страница 6: ...Figure 3 Internal Structure 2...
Страница 11: ...8 XMM801 Timing chart at Power ON Figure 12 Timing Chart 7...
Страница 14: ...Figure 18 Circuit Diagram 10...
Страница 15: ...Figure 19 Parts Layout and Pattern Schematic 11...
Страница 16: ...Figure 19 cont Parts Layout and Pattern Schematic 11a...
Страница 18: ...5 Electric Circuit for Printer Mechanism Figure 22 Connection Diagram 13...
Страница 20: ...Figure 23 TROUBLE 1 PRINTER IS TOTALLY OUT OF WORK 15...
Страница 21: ...Figure 24 TROUBLE 2 INCORRECT FUNCTION OF PRINTER MECHANISM 16...
Страница 23: ...Figure 26 TROUBLE 4 FEED MOTOR IS NOT WORKING 18...
Страница 39: ...34...
Страница 40: ...35...
Страница 41: ...36...