Страница 1: ...AT T AT T System 85 Release 2 Versions 1 2 3 and 4 Remote Module and Remote Group Interface Installation and Test...

Страница 2: ......

Страница 3: ...555 103 112 Issue 1 July 1987 AT T System 85 Release 2 Versions 1 2 3 and 4 Remote Module and Remote Group Interface Installation and Test Copyright C 1987 AT T All Rights Reserved Printed in U S A 4...

Страница 4: ...46219 For more information about AT T documents see AT T Business Communications Systems Publications Catalog 555 000 010 Every effort was made to ensure that the information in this document was com...

Страница 5: ...ted System 17 CABLING AND CIRCUIT PACKS 17 Cable Connector Plates 18 Central Location Rear Connector Plates Phases 1 and 2 18 Remote Location Rear Connector Plate Emergency Transfer 21 ED 1E469 Extend...

Страница 6: ...oose Wiring 66 Fiber Optic Links 67 Central Location ED 1E434 Group 461 or 463 RMI Fiber Link s Phase 1 71 Central Location ED 1E434 Group 461 or 463 RMI Fiber Link s Phase 2 73 Central Location ED 1E...

Страница 7: ...ns 118 634WAAB1 Series 4 and Higher Power Supply 119 551V CSU Options 120 Channel Expansion Multiplexer CEM Options 122 Channel Division Multiplexor CDM 131 Power Grounding and Alarm Connections 146 O...

Страница 8: ...erminating Information 163 ANN17B 163 SN Type Port Circuit Packs 164 ANN16B 164 Front Cover Label 166 SYSTEM TESTS 167 GENERAL 167 RMI SYSTEM TESTS 167 RGI SYSTEM TESTS 169 ANN16B Circuit Pack Inserti...

Страница 9: ...hase 1 15 Figure 11 Rear Connector Plate 845416585 and Locations Phase 1 18 Figure 12 Rear Connector Plate 845416585 and Locations Phase 2 19 Figure 13 Rear Connector Plate 845416577 and Location Phas...

Страница 10: ...icated System Phase 2 53 ED 1E434 Group 84 Connections for a Duplicated System Phase 2 ED 1E434 Group 84 Connections for a Duplicated Common Control and Unduplicated Module Control System Phase 2 58 E...

Страница 11: ...oss Connect Connections 102 Figure 67 Fanning Out Alarm Leads 103 Figure 68 Console Connector Terminating Information 104 Figure 69 Circuit Pack AE W3Switch Locations 105 Figure 70 Attenuator Location...

Страница 12: ...zer Location 145 Figure 97 OLS With No Holdover 146 Figure 98 OLS With Holdover 147 Figure 99 48 V Rectifier With No Holdover 148 Figure 100 Extended Power Reserve 149 Figure 101 CSU CDM and ChM Power...

Страница 13: ...L Loose Wiring Connections Phase 1 44 TABLE M ED 1E434 Group 133 Cable Connections Phase 2 45 TABLE N ED 1E434 Group 9 137 138 and 139 Cable Connections Phase 2 46 TABLE 0 ED 1E434 Group 131 Cable Con...

Страница 14: ...ons 107 TABLE AK Options for Fiber Optic Link Power Levels 110 TABLE AL Switch Settings 118 TABLE AM SMU Options 121 TABLE AN OR Options 122 TABLE AO SM470 Options 122 TABLE AP TM501 Options 123 TABLE...

Страница 15: ...Timing Switch S5 157 TABLE BK Fault Locate Switch S6 157 TABLE BL Connections for 24 Channel CDM 160 TABLE BM Connections for 8 Channel CDM 161 TABLE BN CDM CH1 Through CH8 Connecting Information 162...

Страница 16: ......

Страница 17: ...g installation procedures Included are instructions for hardware requirements cabling details and general guidelines for installation This manual also provides the installation procedures for the Remo...

Страница 18: ...the installation procedures are completed RGI INSTALLATION The installation procedures for the RGI feature and its associated hardware SYSTEM TESTS The testing procedure for Phases 1 and 2 RMI on a D...

Страница 19: ...uplicated control functions common control module control and Time Multiplexed Switch TMS It is possible to have other combinations of duplication The actual connections for these configurations are s...

Страница 20: ...ROL 0 TN402 COMMON CONTROL 1 TN402 LIGHTGUIDE CABLE INTERCONNECT TERMINAL LCIT 4 MHZ COAX CABLE FIBER OPTIC LINK LIGHTGUIDE CABLE INTERCONNECT TERMINAL LCIT 4 MHZ COAX CABLE CENTRAL LOCATION REMOTE LO...

Страница 21: ...L TMS LINK MISC ALARMS COMMON CONTROL 0 1N402 FIBER OPTIC LINK LIGHTGUIDE CABLE INTERCONNECT TERMINAL LCIT DUPLEX FIBER OPTIC RMI LINK TMS LINK TN481 4 MHz COAX 2 0 DUPLEX CABLE FIBER OPTIC 417 4 MHz...

Страница 22: ...ALARMS o o COMMON CONTROL 0 TN402 COMMON CONTROL 1 TN402 LIGHTGUIDE CABLE INTERCONNECT TERMINAL LCIT FIBER OPTIC LINK 4 MHZ COAX CABLE LIGHTGUIDE CABLE INTERCONNECT TERMINAL LCIT 4 MHZ COAX CABLE CENT...

Страница 23: ...8 duplicated remote modules using the TN456 circuit packs The system has a capacity of two RMI carriers for unduplicated systems and four RMI carriers for duplicated systems Each RMI carrier should be...

Страница 24: ...For systems with only one unduplicated RMI carrier located in position 3 in a TMS RMI cabinet with three TMS carriers both sides of the RMI carrier must be powered by the 334A 1 or OLS 1 rectifier TA...

Страница 25: ...he 134A mounting bracket holes on the 1 2 inch plywood backboard 2 Make sure that the plywood backboard is mounted on the wall so that it will not interfere with the 134A hole locations Mount this bac...

Страница 26: ...H To WALLNts THREADH LE O LCITNO LABELATTACHED RY 13 HAMOUNTINGII MLCODIUTED 1E466GROUP FACTSMCICARCHEWINE 20 12TLABELDSIDE CHONINSIDE BRACKETMOUNT SURFACEu MODULAR 48INCHESFROMFLOOR Page 10 Figure 6...

Страница 27: ...he remote location s Only one remote module control carrier with a TN456 circuit pack can be assigned to a central module control carrier with a TN456 circuit pack Unduplicated System The first Module...

Страница 28: ...BETWEEN LOCATIONS LCIT LCIT S MCC 0 MCC 0 MCC 0 MCC 0 MCC 0 MCC 0 MC 0 MC 1 MC 2 MC 3 MC 4 MC 5 CENTRAL LOCATION I REMOTE LOCATION S Figure 7 Assigned Module Control Carriers for Unduplicated System...

Страница 29: ...le to have the remote module control carriers paired to central module control carriers that are in different cabinets Figure 8 is an example of how the module control carriers should be paired for a...

Страница 30: ...MCC 1 MCC 0 MCC 0 MCC 0 MCC 0 MC 0 MC 1 MC 2 CENTRAL LOCATION MC 3 LCIT LCIT S MCC 1 MCC 1 MCC 0 MCC 0 MC 4 MC 5 REMOTE LOCATION S Figure 9 Assigned Module Control Carriers for a Duplicated System Wi...

Страница 31: ...CC 1 MCC 0 MCC 0 MCC 0 MC 0 MC 1 MC 2 CENTRAL LOCATION LCIT S MCC 1 MCC 1 MCC 1 MCC 0 MCC 0 MCC 0 MC 3 Mc 4 MC 5 REMOTE LOCATION S Figure 10 Assigned Module Control Carriers for a Duplicated System Wi...

Страница 32: ...slot 00 13 01 14 etc Refer to Table B for the assignment order TABLE B Assignment Order of TN456 Circuit Packs Unduplicated Phase 2 REMOTE MODULE NUMBER NOTE RMI CARRIER RMI SLOT NUMBER FOR MCC 00 1 o...

Страница 33: ...13 10 1 01 14 11 1 02 15 12 1 03 16 13 1 05 18 14 1 06 19 15 1 07 20 16 1 08 21 17 2 00 13 18 2 01 14 19 2 02 15 20 2 03 16 21 2 05 18 22 2 06 19 23 2 07 20 24 2 08 21 25 3 00 13 26 3 01 14 27 3 02 15...

Страница 34: ...an example of the plate s and location s Two plates must be added for a duplicated system and only one plate lower is added for an unduplicated system Note The 845416585 plate mounts only on R2 cabine...

Страница 35: ...the TMS RMI cabinet f7 Note The 845416585 plate mounts only on R2 cabinet frames If this is a retrofit R1 frame use a standard R1 connector plate to accommodate at least one Amphenol connector It wil...

Страница 36: ...location Note The 845416577 plate mounts only on R2 cabinet frames If this is a retrofit R1 frame use a standard R1 connector plate to accommodate at least two Amphenol connectors It will be necessary...

Страница 37: ...tems Note The 845417229 plate mounts only on R2 cabinet frames If this is a retrofit R1 frame use a standard R1 connector plate that will accommodate at least one Amphenol connector It will be necessa...

Страница 38: ...f the cabinet the bracket is mounted to the right of J58889V fan assembly shelf using the hardware provided The ED 1E469 Group 4 Extended MAAP Bracket has a circuit pack mounted on the back that is de...

Страница 39: ...MAAP When viewed from the front of the cabinet this bracket is mounted on the left cabinet upright as shown in Figure 17 using the hardware provided The ED 1E469 Group 3 Extended MAAP Bracket has a c...

Страница 40: ...FRONT CABINET DOOR LEFT CABINET UPRIGHT ED 1E469 GROUP 3 EXTENDED MAAP BRACKET ZAEY2 Figure 17 ED 1E469 Group 3 Central Extended MAAP Bracket Mounting Location Page 24...

Страница 41: ...shown in Figure 19 using the hardware provided The ED 1E469 Group 2 Extended MAAP Bracket has a circuit pack mounted on the back that is designated ZAEY1 This bracket and the circuit pack connections...

Страница 42: ...FRONT CABINET DOOR LEFT CABINET UPRIGHT ED 1E469 GROUP 2 EXTENDED MAAP BRACKET ZAEY1 Figure 19 ED 1E469 Group 2 Remote Extended MAAP Bracket Mounting Location Page 26...

Страница 43: ...to the ac distribution unit 2 Attach the wrist strap to either wrist 3 Connect the alligator clip to the screw that fastens the door latch to the frame 4 Set option switches 1 and 2 slide type on eac...

Страница 44: ...the rear connector REM DO on the plates 845416585 added as described in the Cable Connector Plates section The connection for module control 01 is for duplicated systems only TABLE D ED 1E434 Group 13...

Страница 45: ...DO KS 16672 L26 28 INCHES 252A CABLE 6 PAIR 24 GAUGE Figure 21 ED 1E434 Group 133 Cable AMP 1 102935 5 COVER 103058 8 COVER 103056 8 Page 29 E56...

Страница 46: ...up 3 Extended MAAP Bracket for each central module associated with RMI as shown in Table E This cable is not required for an unduplicated system TAB LE E ED 1E434 Group 8 Cable Connection s Phase 1 OR...

Страница 47: ...47 902A FLAT CABLE 843636432 LABEL 943CK CONNECTOR E2 943CK CONNECTOR 657 Figure 22 ED W434 Group 8 Cable Page 31...

Страница 48: ...Extended MAAP Bracket for each central module associated with RMI as shown in Table F TABLE F ED 1E434 Group 25 Cable Connection s Phase 1 ORIGINATION CONNECTOR DESTINATION CONNECTOR Module Control 0...

Страница 49: ...ctor plate 845416577 added as described in the Cable Connector Plates section This plate is located at the fan assembly level TABLE G ED 1E434 Group 131 Cable Connection Phase 1 ORIGINATION CONNECTOR...

Страница 50: ...Figure 16 as shown in Table H TABLE H ED 1E434 Group 132 Cable Connection Phase 1 ORIGINATION CONNECTOR DESTINATION CONNECTOR ED 1E469 Group 3 Extended MAAP Bracket MAAP ZAEY2 Extended MAAP Bracket E...

Страница 51: ...or plate 845416577 Then another Group 300 cable is run from EXT MAAP 0 on the same connector plate to EXT MAAP I on the next module control or TMS RMI cabinet This process is repeated until all the mo...

Страница 52: ...e number This is not the number the module is assigned within the total system but is the number assigned the remote module The first remote module may be the sixth module within the system For exampl...

Страница 53: ...N402 E6 E8 E10 E21 ED 1E434 GROUP 84 NOTE CENTRAL MODULE CONTROL CABINET WITH REMOTE MODULE INTERFACE A OR C NOTE LEGS B AND D ARE NOT USED AND SHOULD BE STORED MODULE CONTROL CARRIER 0 TN456 SLOT 25...

Страница 54: ...C B04 05 E6 A B04 06 C B04 07 E13 A B04 08 C B04 09 Eli A B04 10 C B04 11 E12 A B04 12 C 504 13 E10 A B04 14 C 504 15 E17 A B04 16 C B04 17 E15 A B04 18 C B04 19 E16 A 504 20 C 504 21 E14 A B04 22 C 5...

Страница 55: ...MODULE CONTROL CARRIER 1 803 TN456 SLOT 25 B04 7 MODULE CONTROL CARRIER 0 803 TN456 SLOT 25 B04 rCENTRAL MODULE CONTROL CABINET 1 WITH REMOTE MODULE INTERFACE 1 MODULE CONTROL CARRIER 1 B OR D 803 TN...

Страница 56: ...8 C and D B03 09 Ell A and B B04 10 C and D B03 11 E12 A and B B04 12 C and D B03 13 E10 A and B B04 14 C and D B03 15 E 17 A and B B04 16 C and D B03 17 E15 A and B B04 18 C and D B03 19 E16 A and B...

Страница 57: ...E21 NOTE 803 NOTE r CENTRAL MODULE I WITH REMOTE C CONTROL CABINET 7 MODULE INTERFACE 2 rMODULE CONTROL CARRIER o1 TN456 IC 603 I SLOT 25 I COMMOM CONTROL 0 TN402 E6 E8 E10 E21 NOTE NOTE NOTE LEGS B...

Страница 58: ...03 03 E8 0 A B04 E8 1 A B03 04 E8 0 C B04 E8 1 C B03 05 E6 0 A B04 E6 1 A B03 06 E6 0 C B04 E6 1 C B03 07 E13 0 A B04 P13 1 A B03 08 E13 0 C B04 E13 1 C B03 09 P11 0 A B04 E11 1 A B03 10 E11 0 C B04 P...

Страница 59: ...03 18 E15 0 C B04 E15 1 C B03 19 E16 0 A B04 E16 1 A B03 20 E16 0 C B04 E16 1 C B03 21 E14 0 A B04 E14 1 A B03 22 E14 0 C B04 E14 1 C B03 23 E21 0 A B04 E21 1 A B03 24 E21 0 C B04 E21 1 C B03 25 E19 0...

Страница 60: ...48 V and bus bar ground through the MAAP circuit breaker TABLE L Loose Wiring Connections Phase 1 ORIGINATION CONNECTOR CABLE DESTINATION CONNECTOR MAAP Circuit Breaker Line Side GROUP 4 H600 161 BUS...

Страница 61: ...TABLE M ED 1E434 Group 133 Cable Connections Phase 2 ORIGINATION CONNECTOR DESTINATION CONNECTOR RMI Carrier Backplane Position 00 E06 ia II Carrier 00 Connector Plate REM DO RMI Carrier Backplane Pos...

Страница 62: ...each RMI carrier TABLE N ED 1E434 Group 9 137 138 and 139 Cable Connections Phase 2 ORIGINATION CONNECTOR GROUP DESTINATION CONNECTOR RMI Carrier Backplane Position 00 E07 9 ZAEY2 Extended MAAP Brack...

Страница 63: ...GROUP 137 52 GROUP 138 60 GROUP 139 68 943CK CONNECTOR E07 252A FLAT CABLE 843636432 LABEL 943CK CONNECTOR GROUP 9 El GROUP 137 E2 GROUP 138 E3 GROUP 139 E4 Figure 32 ED 1E434 Group 9 137 138 and 139...

Страница 64: ...ate 845416577 added as described in the Cable Connector Plates section This plate is located at the fan assembly level TABLE 0 ED 1E434 Group 131 Cable Connection Phase 2 ORIGINATION CONNECTOR DESTINA...

Страница 65: ...ailable electrical port on the designated module control carrier s Table P TABLE P ED 1E434 Group 200 Cable Connection Phase 2 RMI Carrier Connector E00 E01 E02 E03 Module Control 00 01 00 01 Carrier...

Страница 66: ...MAXIMUM 33 FEET 943CK CONNECTOR EO El E2 OR E3 902A FLAT CABLE 843636432 LABEL 943CK CONNECTOR NEXT AVAILABLE PORT Figure 34 ED 1E434 Group 200 Cable Page 50...

Страница 67: ...control cabinet or TMS RMI cabinet connector plate 845416577 Then another Group 300 cable is run from EXT MAAP 0 on the same connector plate to EXT MAAP I on the next module control or TMS RMI cabinet...

Страница 68: ...the number the module is assigned within the total system but the number assigned to the remote module The first remote module may be the sixth module within the system For example if your remote mod...

Страница 69: ...Figure 36 ED 1E434 Group 84 Coaxial Cable COMMON CONTROL CABINET COMMON CONTROL 0 TN402 E6 E8 E10 E21 ED 1E434 GROUP 84 NOTE TMS RMI CABINET A OR C NOTE LEGS B AND D ARE NOT USED AND SHOULD BE STORED...

Страница 70: ...07 E13 A 00 03 B06 08 C 00 16 B22 09 E11 A 00 05 B08 10 C 00 18 B24 11 E12 A 00 06 B10 12 C 00 19 B26 13 E10 A 00 07 B12 14 C 00 20 B28 15 E17 A 00 08 B14 16 C 00 21 B30 17 EIS A 01 00 BOO 18 C 01 13...

Страница 71: ...E21 COMMOM CONTROL 0 TN402 E6 E8 E10 E21 ED 1E434 GROUP 84 TMS RMI CABINET CONN 8 OR D RMI CARRIER 800 830 00 03 1N456 TN456 8 OR 0 800 830 A OR C A OR C i 3O 800 830 _______ Figure 38 ED 1E434 Group...

Страница 72: ...01 C and D 00 19 B26 and B27 07 00 E13 A and B 00 07 B12 and B13 01 A and B 00 20 B28 and B29 08 00 C and D 00 08 B14 and B15 01 C and D 00 21 B30 and B31 09 00 Ell A and B 01 00 BOO and B01 01 A and...

Страница 73: ...and B09 01 A and B 02 18 B24 and B25 22 00 C and D 02 06 B10 and B11 01 C and D 02 19 B26 and B27 23 00 E21 A and B 02 07 B12 and B13 01 A and B 2 20 B28 and B29 24 00 C and D 02 08 B14 and B15 01 C a...

Страница 74: ...I CABINET A C RMI CARRIER 00 OR 01 TN456 600 830 EVEN RMI CARRIER 00 OR 01 TN456 600 630 EVEN TMS RMI CABINET A C RMI CARRIER 00 OR 01 TN456 800 830 EVEN RMI CARRIER 00 OR 01 TN456 800 630 EVEN Figure...

Страница 75: ...15 B20 04 00 C 00 03 B06 01 C 00 16 B22 05 00 E6 A 00 05 B08 01 A 00 18 B24 06 00 C 00 06 B10 01 C 00 19 B26 07 00 E13 A 00 07 B12 01 A 00 20 B28 08 00 C 00 08 B14 01 C 00 21 B30 09 00 Ell A 01 00 BOO...

Страница 76: ...14 B18 19 00 E16 A 02 02 B04 01 A 02 15 B20 20 00 C 02 03 B06 01 C 02 16 B22 21 00 E14 A 02 05 B08 01 A 02 18 B24 22 00 C 02 06 B10 01 C 02 19 B26 23 00 E21 A 02 07 B12 01 A 2 20 B28 24 00 C 02 08 B1...

Страница 77: ...remote module as shown in Table T TABLE T ED 1E434 Group 97 Cable Connection s Phases 1 and 2 ORIGINATION CONNECTOR DESTINATION CONNECTOR Module Control 00 Backplane E56 ZAEY1 Extended MAAP Bracket El...

Страница 78: ...ED 1E469 Group 2 Extended MAAP Bracket for each remote module as shown in Table U This cable is not required for an unduplicated system TABLE U ED 1E434 Group 98 Cable Connection s Phases 1 and 2 ORIG...

Страница 79: ...This connection is made on the inside of the bracket for each module control cabinet at a remote location TABLE V ED 1E434 Group 93 Cable Connection s Phases 1 and 2 ORIGINATION CONNECTOR DESTINATION...

Страница 80: ...oad Side respectively for each remote module as shown in Figure 42 and Table W TABLE W ED 1E434 Group 96 Cable Connections Phases land 2 ORIGINATION CONNECTOR CABLE DESTINATION CONNECTOR ED 1E469 Grou...

Страница 81: ...E BLACK STRANDED 22 GAUGE BLACK STRANDED EASTON 402646756 GRD BUSBAR EASTON 75 KS 23008 L7 24 GAUGE RED STRANDED 22 GAUGE RED STRANDED FAGTON 402646756 II G PL1 402989057 INSULATE WITH HEAT SHRINK TUB...

Страница 82: ...odule Control 00 Backplane B04 Module Control 00 Backplane B02 Module Control 01 Backplane B04 Module Control 01 Backplane B02 This cable is used for duplicated systems only B04 6 INCHES COAX CABLE 40...

Страница 83: ...These cables are fragile and should be routed from the appropriate carrier to the LCIT Figure 46 outside the overhead duct work Figure 47illustrates how the fiber cables should be routed The procedur...

Страница 84: ...COMPONENT SIDE RIGHT tUP 982C TRANSMITTER L DS RMI LINK L DS COMPONENT SIDE RIGHT llIllJEli 0 tup 9820 RECEIVER COMPONENT SIDE RIGHT INN t UP 9820 RECEIVER TMS LINK Figure 45 Z982J Z982C and Z982D Pad...

Страница 85: ...HES 12 INCHES RIBBON LEAD 22 INCHES LCIT ARRAY SPLICING SHELF 3 TYPE FANOUT 401 SERIES ATTENUATORS OR BUILDOUTS 3 TYPE FANOUT LIGHTGUIDE TYPICAL Figure 46 LCIT With 3 Type Fanout DUPLEX FIBER CABLE Pa...

Страница 86: ...RFACE TERMINAL LCIT LIGHTGUIDE CABLE ROUTING HARDWARE LOCALLY PROVIDED I O CABLE DUCT ASSEMBLY XMT TRANSMIT PADDLEBOARD DUPLEX LIGHTGUIDE CABLE REC RECEIVE PADDLEBOARD Figure 47 Routing of Lightguide...

Страница 87: ...de cable 3 Route the cable out of the module control cabinet to the central LCIT outside the overhead ducts using the locally provided hardware This cable should enter the right side of the LCIT Figur...

Страница 88: ...LEBOARD TRANSMITTER Z982J NOTE 401M BUILDOUT OR ATTENUATOR 401A 5 dB 401B 10 dB 401C 15 dB 4010 20 dB LIGHTGUIDE CABLE ED 1E434 GROUP 461 OR 463 11 FIBER 2 WHITE FIBER 1 BLUE FIBER 2 WHITE FIBER 1 BLU...

Страница 89: ...oup 461 or 463 lightguide cable 3 Route the cable out of the TMS RMI cabinet to the central LCIT outside the overhead dpcts using the locally provided hardware This cable should enter the right side o...

Страница 90: ...7 08 00 16 A22 A23 09 00 05 A08 A09 10 00 18 A24 A25 11 00 06 A10 All 12 00 19 A26 A27 13 00 07 Al2 A13 14 00 20 A28 A29 15 00 08 A14 A15 16 00 21 A30 A31 17 01 00 A00 A01 18 01 13 A16 A17 19 01 01 A0...

Страница 91: ...ER Z982J NOTE TN456 PADDLEBOARD RECEIVER Z982D BACKPLANE PADDLEBOARD CONNECTORS TRANSMITTER 2982J NOTE LIGHTGUIDE CABLE ED 1E434 463 LOCAL LCIT 10 4 8 2 LIGHTGUIDE CABLE REMOTE MODULES Figure 51 Centr...

Страница 92: ...00 16 A22 A23 05 00 05 A08 A09 00 18 A24 A25 06 00 06 A10 All 00 19 A26 A27 07 00 07 Al2 A13 00 20 A28 A29 08 00 08 A14 A15 00 21 A30 A31 09 01 00 A00 A01 01 13 A16 A17 10 01 01 A02 A03 01 14 A18 A19...

Страница 93: ...05 02 15 A20 A21 20 02 03 A06 A07 02 16 A22 A23 21 02 05 A08 A09 02 18 A24 A25 22 02 06 A10 All 02 19 A26 A27 23 02 07 Al2 A13 02 20 A28 A29 24 02 08 A14 Al5 02 21 A30 A31 25 03 00 A00 A01 03 13 A16 A...

Страница 94: ...onding TMS carrier and pin numbers to connect from the TMS backplane to the LCIT as shown in Figures 52 and 53 The number of a remote module is determined by the module that is in the system Install t...

Страница 95: ...9820 N LIGHTGUIDE CABLE ED 1E434 GROUP 460 OR 462 401M BUILDOUT LIGHTGUIDE CABLE TO REMOTE LOCATION LOCAL LCIT 1 3 OR 5 FIBER 1 BLUE 7 9 OR 11 FIBER 2 WHITE 401M BUILDOUT OR ATTENUATOR 401A 5 dB 401B...

Страница 96: ...ll R 02 00 16 A08 T A09 R 03 00 02 A00 T A01 R 04 00 03 A02 T A03 R 05 00 04 A04 T A05 R 06 00 05 A06 T A07 R 07 01 19 A14 T A15 R 08 01 18 A12 T A13 R 09 01 17 A10 T All R 10 01 16 A08 T A09 R 11 01...

Страница 97: ...T A13 R 17 02 17 A10 T A11 R 18 02 16 A08 T A09 R 19 02 02 A00 T A01 R 20 02 03 A02 T A03 R 21 02 04 A04 T A05 R 22 02 05 A06 T A07 R 23 03 19 A14 T A15 R 24 03 18 Al2 T A13 R 25 03 17 A10 T All R 26...

Страница 98: ...EN Z982C BACKPLANE CONNECTORS PADDLEBOARD A01 A15 RECEIVER ODD Z982D 7______ LIGHTGUIDE CABLE ED 1E434 GROUP 460 OR 462 40111 BUILDOUT FIBER 1 BLUE FIBER 2 WHITE FIBER 1 BLUE FIBER 2 WHITE 40111 BUILD...

Страница 99: ...09 R 03 00 and 02 02 A00 T A01 R 04 00 and 02 03 A02 T A03 R 05 00 and 02 04 A04 T A05 R 06 00 and 02 05 A06 T A07 R 07 01 and 03 19 A14 T A15 R 08 01 and 03 18 Al2 T A13 R 09 01 and 03 17 A10 T All R...

Страница 100: ...0 and 01 00 02 A00 T A01 R 04 00 and 01 00 03 A02 T A03 R 05 00 and 01 00 04 A04 T A05 R 06 00 and 01 00 05 A06 T A07 R 07 00 and 01 01 19 A14 T A15 R 08 00 and 01 01 18 Al2 T A13 R 09 00 and 01 01 17...

Страница 101: ...8 00 and 01 02 16 A08 T A09 R 19 00 and 01 02 02 A00 T A01 R 20 00 and 01 02 03 A02 T A03 R 21 00 and 01 02 04 A04 T A05 R 22 00 and 01 02 05 A06 T A07 R 23 00 and 01 03 19 A14 T A15 R 24 00 and 01 03...

Страница 102: ...3 lightguide cable 3 Route the cable out of the module control cabinet to the remote LCIT along the outside of the overhead ducts using locally provided hardware Figure 47 illustrates the routing of l...

Страница 103: ...NTROL CABINET PADDLEBOARD TRANSMITTER 2982J NOTE PADDLEBOARD RECEIVER Z982D PADDLEBOARD TRANSMITTER Z982J NOTE PADDLEBOARD RECEIVER Z9820 MCC1 TN456 SLOT 25 A05 BA CKPLANE CONNECTORS A04 MCCO TN456 SL...

Страница 104: ...the ED 1E434 Group 460or 462 lightguide cable 3 Route the cable out of the auxiliary cabinet to the remote LCIT along the outside of the overhead ducts using locally provided hardware Figure 47 illus...

Страница 105: ...60 OR LIGHTGUIDE 462 WHITE FIBER 2 401M BUILDOUT REMOTE MODULE CONTROL CABINET PADDLEBOARD RECEIVER 29820 PADDLEBOARD TRANSMITTER Z982C PADDLEBOARD RECEIVER Z982D PADDLEBOARD TRANSMITTER Z9B2C MODULE...

Страница 106: ...H INSTALLATION COMMON CONTROL CABINET JIT32 7 t LOCATED 01 BELOW FAN ASSEMBLY LEVEL ED 1E434 GROUP 300 48PX GRD 48 ENSMT ED 1E434 GROUP 300 SEE TABLE CC FOR UNIT TYPE CONNECTIONS ED 1E434 GROUP 300 YE...

Страница 107: ...ns should be made in the yellow wall field to each RMI carrier PROVIDED DURING INITIAL SWITCH INSTALLATION COMMON CONTROL CABINET LOCATED D1 BELOW FAN ASSEMBLY LEVEL ____L 5 32 7 ED 1E434 GROUP 300 48...

Страница 108: ...Unit 6 3 Unit 23 16 Unit 5 29 42 Unit 8 4 Unit 25 17 Unit 7 30 Unit 27 43 Unit 10 5 Unit 28 18 Unit 9 31 Unit 29 44 6 Unit 28 19 Unit 11 32 Unit 31 45 Unit 13 7 Unit 30 20 Unit 12 33 AUXCTMP 46 Unit 1...

Страница 109: ...EL 22 GRD 23 GRD 844670505 24 GRD ONLY 2 ALARMS CAN BE ACTIVATED FOR EXTERNAL EQUIPMENT ALM1I AND ALM2I THERE MUST ALSO BE A GROUND LEAD FOR 48V FROM PIN 24 Figure 60 Remote Location Cross Connections...

Страница 110: ...A block diagram of the Remote Console connection is shown in Figure 61 This feature uses the 107A Optically Remoted Peripheral Interface ORPI in a fiber optic link subsystem in combination with the TM...

Страница 111: ...ALARM COMMON CONTROL I I YO I i BLUE 1 0 TRANS TRANS WHITE 2 MODULE CONTROL CAB MODULE CONTROL CAB 48 V FAN ASSEMBLY 00 TO TMS LINK GND ATTENDANT CONSOLE MODULE MODULE RMI LINK CONTROL FIBER CONTROL C...

Страница 112: ...to the ORPI WARNING FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE Figure 62 ORPI Warning Label Install the LCIT An LCIT is required at the central and r...

Страница 113: ...G BLOCK ASSOCIATED 48V ACAL ACK NC TO CONNECTING BLOCK ASSOCIATED GRD WITH CSL POWER CSLO 3 SEE 48 V 555 103 104 NC SYSTEM 85 CROSS CONNECT FIELD 1 20 o o o 4 o o 5 0 o o 6 o 70 o 0 8 0 o o 10o o 0 11...

Страница 114: ...34 R BR 17 IOXA4 9 ER R 18 I0884 35 R SL 19 IORA4 10 SL R 20 BK BL 21 BL BK 22 ALM 37 BK 0 23 ACK 12 0 BK 24 LEAD DESIGNATION DI ON ORPI LEAD COLOR CONNECTING BLOCK TERMINAL 48 ACAL 38 BK OR 25 OR OK...

Страница 115: ...igure 64 TABLE AG Cable Group 107A ORPI Y1 REC YO TRANS CABLE GROUP ED1E434 11 CABLE TYPE MICRON LENGTH FT 464 LA2A B 50 10 15 20 25 30 40 50 75 100 465 LL2A B 62 5 401 TYPE ATTENUATORS WHITE 2 SEE TA...

Страница 116: ...emote console receives its power from a remote module control or port cabinet with a power supply LCIT to ORPI Connections Use Table AH to determine the proper cable group Make the connections between...

Страница 117: ...7 0 R 14 I0RB3 33 R GR 15 I0583 a OR R 16 IOX84 34 R BR 17 IOXA4 9 BR R 18 IORB4 35 R SL 19 IORA4 10 SL R 20 OUTALM 36 BK BL 21 OUTACK 11 BL BK 22 37 BK 0 23 12 0 BK 24 LEAD DESIGNATION DI ON ORPI LEA...

Страница 118: ...0 IOX81 IOXA1 1TO CONNECTING BLOCK IORB1 IASSOCIATED WITH IORA1 IREMOTE CONSOLE 1 IOX82 IOXA2 TO CONNECTING BLOCK IORB2 IASSOCIATED WITH IORA2 REMOTE CONSOLE 2 ION3 IOXA3 TO CONNECTING BLOCK IORB3 ASS...

Страница 119: ...eads must be fanned out Use the information in Figure 67 to fan the leads out FROM D1 ON REMOTE ORPI CONNECTING BLOCK CHOSEN TO FAN OUT ALARMS OUTALM OUTACK COMALARM 0 TO CONSOLE 0 o o TO CONSOLE 1 O...

Страница 120: ...NET 110 BLOCK ASSOCIATED WITH CONSOLE BEING CONNECTED IOXB 1 DATA IN IOXA 2 0 DATA IN IORB o 3 DATA OUT IORA 4 DATA OUT T 5 T R o 8 R T1 0 6 0 Ti R1 010 e R1 GNU o o 9 CROCE GRDCF o o 10 GRDCF ACK o o...

Страница 121: ...or NORMAL 2 Switch 2 is used to select power level for the transmitter Settings are HALF or FULL 3 Switch 3 is used for factory test only Ensure that S3 is in the NORMAL position as shipped from the f...

Страница 122: ...LEDs are red the link is in an overdriven condition c If a single LED is red the link is in an underdriven condition 5 Adjust the fiber optic link if overdriven or underdriven by changing the power le...

Страница 123: ...to full to half 019 L HALF 5 dB power power 0 53 ml ATTEN B 0 30 401A to 0 85 km 10 dB 2800 Switch 2 Switch 2 4900 ft to half to half 0 53 L FULL 5 dB power power 0 93 ml ATTEN B 0 85 401A to 1 49 km...

Страница 124: ...HALF POWER REPLACE WITH ATTENUATOR WITH 5 dB HIGHER VALUE AND SWITCH TRANSMITTER TO FULL POWER SWITCH TO FULL POWER REPLACE WITH ATTENUATOR WITH 5 dB LOWER VALUE AND SWITCH TRANSMITTER TO HALF POWER...

Страница 125: ...on distance between central and remote locations Table AK 3 Determine the condition of the fiber optic link by observing the LEDs on the receiver paddleboard Z982D These conditions are a If one green...

Страница 126: ...9 L Half 5 dB to full to full 0 53 mi power power 0 30 ATTEN to 0 85 km 10 dB 2800 Switch Switch 4900 ft XMTR XMTR 0 53 L Full 5 dB to half to half 0 93 mi power power 0 85 ATTEN to 1 49 km 0 dB 4900...

Страница 127: ...UATOR WITH 5 dB HIGHER VALUE AND SWITCH TRANSMITTER TO FULL POWER SWITCH TO FULL POWER REPLACE WITH ATTENUATOR WITH 5 dB LOWER VALUE AND SWITCH TRANSMITTER TO HALF POWER 401 A B C D M 5 10 15 20 0 dB...

Страница 128: ...ANN 15B CE CEM ANN168 1 1 CM COM SN2288 SN238 SN2708 OR ANN178 TELEPHONE SET CSU CSU LESS THAN 100 MILES CENTRAL SYSTEM 85 LOCATION REMOTE LOCATION Figure 73 Remote Group Interface Block Diagram CENT...

Страница 129: ...PORT 0 4 PORT 0 PORT INTFCE 2 4 ANN16B 0 Figure 74 Remote Group Housing J 58889AN 1 0 0 SD I E600 01 CSU ALM 4 1 D INT C 5 E 2 E TX 1 i PORT OT CEM ALM P D T C CD P 7 T I 9 PORT 707 P 0 0 0 R 3 T 1 0...

Страница 130: ...the wall mounting bracket with the slotted holes at the top place the bracket over the two screws then tighten 5 Insert wood screws in remaining seven holes of the wall mounting bracket and then tigh...

Страница 131: ...gure 78 J58889AN 2 Front Cover Description To install or verify the option settings on the CAL1B board remove the housing cover one piece front and side After the front cover has been removed turn the...

Страница 132: ...T 9 CAL1B Figure 79 J 58889AN 1 Circuit Pack Location CA L5 z 1 007 AhN1 68 A POWER 06 17 pfIRT J 027 ORi 3 f PORT 4 gm y PoRT 7 z07 z z z AhN1 6B 1 PORT as INSERT COMPONENT INSERT BOARDS VIElisapoENT...

Страница 133: ...he CAL1B is reinserted reconnect the cable After the cable is reconnected care should be taken that the cable is placed in the cable trough so it will not interfere with the operation of the fan POWER...

Страница 134: ...m 85 is connected to another system or device that has similar equalization options a phantom point midway between the two systems should be chosen as the distance The options at both systems should b...

Страница 135: ...sn t set the input voltage switch to the 110 V position using a nonmetallic tool See Figure 83for the switch locations Note Only Vintage 4 and above power supplies are set to 110 V Older vintages of t...

Страница 136: ...from the hardware CSD The option switch location for the system monitor unit and the office repeater boards of the CSU are shown in Figures 84 and 85 n fl 1 1 El 1 DOPISW CHIDIP El Ii U i I EPIRL I D...

Страница 137: ...A S S5 I AB OFFICE REPEATER Figure 85 Office Repeater The Signal Monitor Unit SMU option settings are shown in Table AM TABLE AM SMU Options OPTION SWITCH SETTING 1 C All Ones 2 0 1 0 ESS 2 C 16 3 C Z...

Страница 138: ...urrent C G J Y OUT AA B ARTIFICIAL LINE OPTION SELECTION dB LEVEL Si 55 0 db C NA 7 5 db A A 15 db B B Channel Expansion Multiplexer CEM Options The settings for each individual installation can be de...

Страница 139: ...E 0 133 ft C C 0 NOT USED 134 267 ft C 0 C 268 400 ft C 0 0 401 533 ft 0 C C 534 655 ft 0 C 0 FRAMING FORMAT D4 C Fe 0 LINE FORMAT BIPOLAR C B8ZS 0 The option settings for the TM500 line X and Y optio...

Страница 140: ...G FORMAT D4 C Fe 0 LINE FORMAT BIPOLAR C B8ZS 0 The option switch settings for the MC90069A 1 are shown in Table AR TABLE AR MC90069A 1 Options OPTION SWITCH I 2 3 4 5 6 7 8 CLOCK REFERENCE Local BCM...

Страница 141: ...Channels SWITCH ROCKER 1 2 3 4 5 6 Line X 1 C C 0 0 0 0 Channels 1 12 2 0 C 0 0 0 0 Line X 1 C 0 0 0 0 0 Channels 13 24 2 0 0 0 0 0 0 Line Y 3 C C 0 0 0 0 Channels 1 12 4 0 C 0 0 0 0 Line Y 3 C 0 0 0...

Страница 142: ...C S C S C S C S C S 4 5 6 1 2 3 T N T N T S C S C S C S C S C S 1 2 3 5 6 4 T N T S T S C S C S C S C S C S 2 3 5 6 1 4 T S T S T S C S C S C S C S C S 1 4 6 2 3 5 T N T N T N C S C S C S C S C S 5 1...

Страница 143: ...T CCCCCCCC 1 2 3 4 5 6 T T CCCCCCCC 2 4 5 1 3 6 T CCCCCCCCT 3 4 1 2 5 6 CCCCCCCCTT 3 3 6 1 2 4 5 TTT CCCCCC 2 3 4 5 1 6 T T T CCCCCC 1 4 6 2 3 6 TT CCCCCCT 1 3 5 2 4 6 T T CCCCCCT 1 2 4 3 5 6 T CCCCCC...

Страница 144: ...BLE AW MC90007A 1 Dip Switch Options OPTION SWITCH 1 2 3 4 5 6 7 8 CLOCK REFERENCE Local BCM 0 0 0 0 C 0 Line X C 0 0 0 0 C Line Y 0 C 0 0 0 C Line X 0 0 C 0 0 C ECHO TAIL LENGTH LINE X 32 Not used or...

Страница 145: ...C S C S C S C S C S C S 2 3 5 6 1 4 T S T S T S C S C S C S C S C S C S C S C S C S 2 3 4 5 1 6 T N C S T N C S T N C S C S C S C S C S C S C S 1 3 4 5 2 6 T N C S T N C S T S C S C S C S C S C S C S...

Страница 146: ...1 3 2 4 5 6 T S T S T S C S C S C S C S C S C S C S T N T N 1 2 3 4 5 6 T N C S T N C S T N C S C S C S C S C S T N T N 6 2 4 6 1 3 5 T N T N T N T N T N T N C S C S C S C S C S C S 1 4 6 2 3 5 T N T...

Страница 147: ...ume that from a given site the following services are to be provided a E M service for one subscriber b 4 8 kbps data service for one subscriber c 56 64 KNX data service for one subscriber operating a...

Страница 148: ...SELECT TIME SLOT COM CHANNEL UNIT TYPE DATA 56 64KXN DATA 0 19 E M CARD SLOT 8 7 6 5 4 3 2 1 1 _ _ 2 3 4 5 _ 6 7 8 a _ _ 9 _ _ 10 11 12 13 14 _ _ 15 16 _ _ 17 18 19 20 21 22 3 24 Place jumpers on both...

Страница 149: ...5 oo oo oo oo oo oo oo oo 6 00 00 oo 00 0000 oo oo 7 oo oo oo oo oo tl oo oo 8 oo oo oo oo oo oo oo 9 oo oo oo oo oo oo oo oo 10 oo oo oo oo oo oo oo oo 11 oo oo oo oo oo oo oo oo 12 CHANNEL SELECT o...

Страница 150: ...nit using Figure 88 and Table AZ S6 S5 El LOOPTIME OFF ON CH BK D I MODE IN OUT A Si El D I D I MODE IN OUT B OR CHNL BK LOOP ACO L0 C RA EL MC G A R YE LOOP AC S3 PTO LOCAL AR FSTI REM AY IITSTD CGA...

Страница 151: ...end is optioned for LOOPED except when the DS 1 facility provides timing In that case bothCDMs are optioned for LOOPED Four Wire E M Channel Unit Set the options on the 4 wire E M channel unit using t...

Страница 152: ...IO as shown in Table BB S2 S3 S10 to ON 1 1 IN S2 IICI OUT IN OUT S8 Si TEST SWITCH S3 13W TRANSMIT ATTENUATOR cm cm OM 1311 S9 RECEIVE ATTENUATOR NORMAL TANDEM PBX IN OUT IN OUT IN OUT IN OUT IN OUT...

Страница 153: ...INDICATES A BLOWN FUSE LOOP Figure 90 Asynchronous Data Channel Unit Switch Locations and Setting TX ATTEN RI ATTEN DS5 DS1 t 052 DS3r t DS41 1 DSC Si 1 2 4 8 1 6 3 2 6 4 12 8 EU CM EU EU 56 57 IN 44...

Страница 154: ...etting for E M signaling OFF II ON III 4 OFF 5 OFF E lead routines on CGA Idle immediately 6 5 ON Busy immediately 6 OFF 5 OFF Idle immediately then busy after a delay 6 ON Most PBX interfaces will re...

Страница 155: ...immediately 1 2 OFF ON Busy immediately 1 2 ON OFF Idle immediately then busy 3 4 OFF ON E M Operation E lead Busy GND S5 GND S2 5 OFF M lead Busy BAT 3 4 ON ON PLR Operation E lead busy S5 BAT S2 5...

Страница 156: ...gs OPTION SWITCH DESCRIPTION LOCATION POSITION MPO Transmit and receive W1 W2 IN Tristate mode is activated Both data and control bits are received transmitted simultaneously on the same pair or wires...

Страница 157: ...RS 232C Switch Locations TABLE BD RS 232C Option Settings ALARM OPTION SWITCH POSITION DESCRIPTION CTS IN Delays clear to send signal for 40 msec OUT Normal setting Delays clear to send signal for 8 m...

Страница 158: ...Data Channel Unit Use the hardware CSD and Figure 94 to set the options on the data channel unit 1 2 3 4 5 6 NORM Si REQUEST TO SEND SWITCH S2 ON DS1 PARITY RTS D Figure 94 56 64 kbps Synchronous Dat...

Страница 159: ...g the hardware CSD Figure 95 and Table BE JUMPER BLOCK O 0 0 O 0 0 0a 0 0 0c 0 0 O 0 0 O 0 0 Si XMT CLOCK SELECT EX INT DTR TMD DSR DMD CO RRD CTS CSD REMOTE LOCAL _ o 1 1 LOOP o cn RL OFF LL CC CC S2...

Страница 160: ...msec normal operation TR1 3 ONt Enables polling Tristate OFF Normal operation RR 4 ON Receiver ready normal operation Receiver ready control OFFt Receiver ready continuous operation Remote Local loopt...

Страница 161: ...with the component side out The components are located on the lower half of the equalizers 5 Close and secure the Data Service Panel TABLE BF CDM Equalizers 48 V GND VISUAL ALARM AUDIO ALARM 20 Hz PAR...

Страница 162: ...The Remote Group Housing must have an OLS 634WAAB board in slot 06 for this power arrangement This connection is shown in Figure 97 TO 125 V AC 60 HZ 20 A FUSED DEDICATED LINE FURNISHED BY CUSTOMER O...

Страница 163: ...shown in Figure 98 AC 9C DISTRIBUTION UNIT Z337A 120 V AC NORMAL OPERATION 144 V DC HOLDOVER OPERATION 120 V AC 144 V DC 144 V DC NOMINAL HOLDOVER Air Z338A P1 TO APPROVED BUILDING GROUND NOTE THIS T...

Страница 164: ...re 99 TO 120 V AC p4 60 HZ 20 1 A FUSED DEDICATED LINE FURNISHED BY CUSTOMER AC DISTRIBUTION a SINGLE POINT GROUND RD CI 48V RECTIFIER 4 1 J3 1 48 V 1 J1 2 GRD GRDL 48 GRD TS3 NOTE 1 5 i i TO CABINET...

Страница 165: ...48 V to the dc dc converter The battery plant should be engineered by AT T National Customer Support Center This connection is shown in Figure 100 TO APPROVED BUILDING GROUND BATTERY PLANT 48 TS5 NOT...

Страница 166: ...L DIVISION MULTIPLEXER AUDIBLE ALP ALP RETURN TB1 6 o 7 ED 1E434 11 GRP 161 P14 CDMALM CEMRTN CHANNEL EXPANSION MULTIPLEXER AUDIBLE ALP ALP RETURN TB2 10 22GA 0 P16 CEMALM 22GA ED 1E434 11 GROUP 161 E...

Страница 167: ...cables Then snap the latch at the retainer into place Detailed instructions are furnished with the RGH T1 Carrier Directly to RGI Connect the Ti carrier directly to the RGI using the information in Fi...

Страница 168: ...P HOUSING D1 02 D3 04 D7 OR 08 DO OR 05 ED 1E434 11 GRP 115 NOTE This filter is required only if RGH is equipped with ANN176 but a filter is required for each connector associated with ANN1713 ED 1E43...

Страница 169: ...GRD ED 1E434 11 GRP 159 ED 1E434 11 GRP 115 NOTE This filter is required only if RGH is equipped with an ANN17B but a filter is required for each connector associated with ANN17B CH1 CH8 AAAAAAAA ED...

Страница 170: ...er is required only if RGH is equipped with an ANN1713 but a filter is required for each connector associated with ANN1713 TS1 ZR 18 ZT 19 ZR1 20 ZT1 21 YR1 23 T1 24 YR 25 YT 26 XR1 27 XT 28 XR 29 XT...

Страница 171: ...GRP 115 NOTE This filter is required only if RGH is equipped with ANN17B but a filter is required for each connector associated with ANN17B Ti R1 TO REMOTE GROUP INTERFACE R1 o3 o4 o5 6 Ti IN GRD Ti O...

Страница 172: ...cabinet The repeater at the remote location is wall mounted in a small mounted rack equipped with its own 48 V power supply Options Use Figure 107 and Tables BC BH BI BJ and BK to set the options on t...

Страница 173: ...sec 10 second loop up detect interval TABLE BK Fault Locate Switch S6 SETTING OPTION OPEN With fault locate filter CLOSED Without fault locate filter Connections All of the connections should be wire...

Страница 174: ...E AUXILIARY CABINET REPEATER CENTRAL LOCATION REMOTE LOCATION CROSS CONNECT FIELD 764A SHIELDED CABLE CROSS CONNECT FIELD ED 1E434 GRP 300 C 0307 WALL MOUNT RACK REPEATER I REMOTE GROUP HOUSING ANN168...

Страница 175: ...N TO CABLE PAIR TO REMOTE LOCATION RECEIVE NOT CONNECTED UNLESS REMOTE DC LOOPBACK IS USED NOT CONNECTED UNLESS EQUIPPED WITH FAULT LOCATOR TO FUSE PANEL IF REPEATER IS IN AUXILIARY CABINET OR TO LOCA...

Страница 176: ...R RI M BL BK II 22 T Ti E 12 BK 0 37 23 R RI M 0 BK 12 24 T TI E 13 BK G 38 25 R RI M G BK 13 26 T Ti E 14 BK BR 39 27 R RI M BR BK 14 28 T Ti E 15 BK S 40 29 R RI M S BK 15 30 T Ti E 16 Y BL 41 31 R...

Страница 177: ...7 14 T Ti E 8 R G 33 15 R RI M G R 8 16 R BR 34 17 BR R 9 18 R S 35 19 S R 10 20 BK BL 36 21 BL BK 11 22 BK 0 37 23 0 BK 12 24 BK G 38 25 G BK 13 26 BK BR 39 27 BR BK 14 28 BK S 40 29 S BK 15 30 Y BL...

Страница 178: ...1 OUTI 2 P 4 T 2 3 RX1 RX1 RD1 RD1 RX1 OUT2 3 R 6 Ti 3 4 RTS RTS RS RTS 4 C 7 4 5 CTS CTS CS CTS 5 D 9 5 6 DSR DM DSR E II 6 7 SG SG SG SG OUT5 7 B 19 7 8 CO RR CO OUT7 13 F 13 8 9 LL 19 10 12 10 RL I...

Страница 179: ...T02 28 W G P 0 R02 3 G W V1T2 T03 29 W BR V1R2 R03 4 BR W CT2 104 30 W S CR2 R04 5 S W P 2 T05 31 R BL P 2 R05 6 BL R V1T4 T06 32 R 0 V1R4 R06 7 O R CT4 TO7 33 R G CR4 R07 8 G R P 4 T08 34 R BR P 4 R...

Страница 180: ...W 4 12 SIO TTO W GR 5 R2 S20 TRO GR W 6 T3 W BR 7 R3 BR W 8 R12 RT2 W SL 9 R22 RR2 SL W 10 512 112 R BL II S22 1R2 BL R 12 R 0 13 O R 14 ANN16B 5N228B SN238 EIA INTERFACE SN270B GENERAL PURPOSE PORT...

Страница 181: ...GNATIONS CONNECTORPIN CONNECTOR NUMBER LIN 26 LIP 1 L175 27 2 LON75 28 LOP175 3 00 LON120 DO 29 LOP120 4 30 LON 5 LBACK2R8 31 LBACK1R8 6 LIN 26 LIP 1 L175 27 2 LON75 28 LOP175 3 05 LON120 D5 29 LOP120...

Страница 182: ...or by using PROC 290 Word 2 The instructions for using PROC 290 Word 2 are contained in AT T System 85 Feature Translation Service Manual 555 102 107 R2V2 or 555 103 107 R2V4 CENTRAL SWITCH REFERENCE...

Страница 183: ...ack is not transmitting or receiving data properly This condition could be caused by a problem with the fiber optic link connections option switches or a faulty circuit pack Note A common problem caus...

Страница 184: ...ted the WAIT indicator is turned on 5 When the unit type is tested the WAIT indicator is turned off and a summary is displayed 6 If no circuits in the unit type tested failed the following summary is...

Страница 185: ...B is performed The RED LED on ANN16B is turned on then off The GREEN LED on ANN16B is turned on then off 2 If the ANN16B hardware test passes both LEDs remain off If the ANN16B hardware test fails the...

Страница 186: ...aintenance mode bit is probably activated by another facility Contact the local or remote maintenance facility and ask them to release the maintenance mode bit in the MODE display procedure 9 When the...

Страница 187: ...ble 30 84 Coaxial Cabling 36 9 137 138 and 139 Cables 46 92 Cable 66 93 Cable 63 96 Cable 64 97Cable 61 98 Cable 62 ED 1E469 Extended MAAP Brackets 22 Equalization 45 Extended Power Reserve 49 INDEX F...

Страница 188: ...nstalling Circuit Packs 115 RGI System Tests 69 RMI System Tests 167 RS 232C Option Settings 141 RS 422 Interface Subboard 140 SN Type Port Circuit Packs 164 System Installation 3 Tests 67 T1 Carrier...

Страница 189: ...text 0clear 0Clear 0Adequate 0complicated El complicated Is the information in this document too technical or not Too About technical enough 0technical 0right 0 Not technical enough Is anything missin...

Страница 190: ......

Страница 191: ......