background image

... 

co 

111 

� 

• 

� 

� 

.  ' 

GI2A  HANDSET 

H408 

CORD 

, .. �"  ---

�  8.!� 

42SK  NETWORK 

(5-Y) 

® 

-----"'"'c:w_::sr:..c•c:•'---' 

� 

� 

� 

§ 

� 

- ±---

:i_

J

9  6 

!9 

2  31784 

2 021 

18152825 

16 

26 

34 33 24 2322 

32 

330 

6

1

12 

49 

15 

5

7

  2131

1 317108141618 

(Y-BR) 

(BR) 

(R) 

IWI 

{W-BR) 

(Y-o) 

G  R 

(S  R) 

Y) 

' BLI 

(S-'Y) 

Jl

rr rr r rr r rnrrr---nrr-r-r-r-r-----n-nrrrn-------rn  nr-rr--r--rr-nnnnn, 

NOTES 

CONDUCTOR  COLORS 

FOR  D50AB  CORD  AND 

P-900212  CORD  ASSEMBLY  ARE  •OENTICAL 

2  LINE  SWITCH  OPERATING  SEQUENCE 

abBREAKS 

be  MAKES 

de 

MAKES 

lq 

BREAKS 

WHEN  RESTORING  HANDSET, 

d� 

MUST 

BREAK  BEFORE  be  BREAKS 

INSULATE  AND  STOR£ 

SPARE  TERMINAL  OR 

0-161488  CONNECTOR 

@) 

18 

VAC 

BUZZER 

18 VOC  BUZZER 

IOVAC8UZlER 

®

WITHOUT  BUSY  LAMP 

lA  KTS  WITH  BUSY  LAMP 

IAI  OR  IA2  KTS  WITH  BUSY  LAMP 

Fig.  1 3A-267181M  Telephone  Set,  Connections 

,------_j 

TO  FIG 

138 OR 13C 

BSP 503-550-101-i03_1970-12-15.jpg  Scanned  by Frank  Harrell, {Cowboy  Frank) Castle  Rock,  Colorado  Apr 29, 2012  21:39:48 

iii 

"' 

!-I 

"' 

!l 

"' 

.,.. 

"' 

"' 

Содержание Call-a-matlc 2671B1M

Страница 1: ...1A2 or 6A KTS with or without speakerphone and station busy lamp Note Speakerphone can be either internal or external Ordering Guide Note When ordering a 2671B1M telephone set depending on the servic...

Страница 2: ...5081 FACEPLATE Page 2 39A POWER UNIT MOUNTING CORDS Fig 2 Station Modular Arrangement 2671B1M Telephone Set BSP S03 550 101 i03_1970 12 02 jpg Scanned by Frank Harrell Cowboy Frank Castle Rock Colorad...

Страница 3: ...er e1oudspeaker 760A phone e Unit Control 5 5 B or modified5 5A eTransformer 2012 B eSix service configurations by addition of modular and optional items to 2671B1M telephone set Table A eChoice of ca...

Страница 4: ...Requires a P 90D234 relay assembly and external 6668 transmitter Relay assembly is in stalled in place of 6748 transmitter Operating Features a 518 Dial eRECORD button when pulled places 518 dial in r...

Страница 5: ...front of the network Fasten guard with two screws supplied with the telephone set and connect leads as shown in Table G 3 Mount the KS 8109L2 buzzer if required to the plastic block on left side of 35...

Страница 6: ...ided the collar buttons and caps must be removed from the 63 5 type key before installing the250 type faceplate Note 63 5 type key is left in place but is electrically inoperative Rewire set as shown...

Страница 7: ...e in Typewriter and that the plug is placed in the proper receptacle Either error will cause circuitry problems and extreme difficulty in removing the plug 3 06 When selecting a location for installin...

Страница 8: ...portion island between YZ and 1 appears 4 Peel off existing designation strip starting at island 5 Start new strip at island and apply while rotating thumbwheel 6 Replace faceplate which should resto...

Страница 9: ...one is heard depress CALL button again to complete dialing ISS 3 SECTION 503 550 101 Note If it is desired to bypass the access code for example with night service push CALL button before lifting hand...

Страница 10: ...replacing set install customer s indexed cartridge in new set to avoid necessity of entering listings on new cartridge 5 04 If51B dial is not operating properly 1 Check power supply to set 2 Look for...

Страница 11: ...store BR V key lead from 8 of front terminal board Connect stored V 0 key strap to 8 of front board When internal speakerphone is furnished disconnect insulate and store Y G G Y hold lamp leads from...

Страница 12: ...PHONE LEAD SUPPLY MTG CD CONDUCTOR SET TERMINAL DESIGNATION TERMINAL PIN COLOR J2 AC AC 41 Y BL 16 AC AC 16 BL Y 14 COM GRD 25 S V 17 Caution Proper supply connections must be made as shown in Table F...

Страница 13: ...HONE AI LEAD AT EQUIPMENT 4 IF POLARITY GUARD IS REQUIRED SEE TABLE G r IJ I WI R SI 5 R IS YI GJ BL R T q FRONT TERMINAL BOARD NOTE II 0 0 0 6 NOTE 5 NOTE 1 0 7 L RO R4 R2 K RS Ql w A a_ R7 R3 H RB l...

Страница 14: ...CONNECTOR 4 IF POLARITY GUARD IS REQUIRED SEE TABLE G 5 LEADS ARE INSULATED AND STORED AND MUST BE TERMINATED AS SHOWN INSULATE AND STORE OPTIONS lA KTS IAI OR IA2 KTS 20128 TRANSFORMER FRONT TERM BOA...

Страница 15: ...AND P 900212 CORD ASSEMBLY ARE OENTICAL 2 LINE SWITCH OPERATING SEQUENCE abBREAKS be MAKES de MAKES lq BREAKS WHEN RESTORING HANDSET d MUST BREAK BEFORE be BREAKS INSULATE AND STOR t SPARE TERMINAL OR...

Страница 16: ...BLI S V REAR TERMINAL BOARD 900212 CORD SSEMSLY 050A8 MT G CORD EXTERNAL I SEE NOTE I FIGIMI I 1 I I 45 2021 4644 41 16 25 49 47 17 22 42 I 23 26 27 28 3 4 29 5 50 31 6 1 32 8 33 54 9 10 35 H 36 3712...

Страница 17: ...8244318 H 1 ___ h 50 2 23 26 27283 4 Jfujuj _ j J f _j_lj _fJ J 11 u 1 I 1 1 I t 11 RINGER 39A POWER SPEAKERPHONE IA II I OR IA2 LEADS SUPPL1 LINE CKT 29 5 30 31 6 7 32 833 34 9 10 35 II 36 37 1213 19...