background image

Brix scale 

 

Brix represents the weight of sucrose in 100 grams of sucrose solution as percentage by weight. When other dissolved solids are 
present in the solution, Brix conversion may be applied. 
Brix is a measure of the total dissolved solids in a solution and indicates the combined concentration of all soluble substances, 
such as sugar, salt, protein, and acids. 
 

Automatic Temperature Compensation 

 

The readings are corrected, based on the temperature of the prism, within the automatic temperature compensation range. 
【Caution】 

 

Measurements may fluctuate with hot or cold samples. Wait for approximately 20 seconds to press the START button. 
Measurements will stabilize once the instrument acclimates to the sample temperature. 

 

Storage and Maintenance 

 

Store the instrument in 
a dry place away from 
direct sunlight. 
Exposure to humidity 
and heat may damage 
the instrument. 

 

Do not use organic 
solvents (paint 
thinner, benzene, 
gasoline, etc.) on the 
plastic body case. 

 

Clean and dry the sample 
stage thoroughly, following 
the 

Cleaning

 instructions.   

Store the unit away from 
direct sunlight at a stable 
temperature with as little 
fluctuation as possible.

 

 

Repair and Warranty 

 

The instrument is warranted for one year from the date of purchase. This warranty is void if the instrument shows evidence of the 
following. Send the included batteries as well if they are still in use. 

 

Having been disassembled by unauthorized personnel 

 

Damages to the prism and/or sample stage 

 

Water damage or having been dropped 

 

Having been misused and/or operated outside the environmental specifications 

 

Leakage from batteries other than those included with the unit 

Repair services are available for a fee after the warranty expires. 
Contact an ATAGO authorized service center for service and support. 

Please have the serial number information ready when contacting a service center. 

 

Specifications 

 

Measurement mode 

(1)

 

Regular (single measurement) 

  Sample volume 

At least 0.3mL 

 

(2)

 

Continuous (measure and display repeatedly) 

  Measurement time 

Approx. 3 seconds 

Measurement range 

0.0 to 85.0% Brix   

  Power supply 

Two (2) AAA alkaline batteries 

 

(Automatic Temperature Compensation) 

  Battery life 

Approx. 11,000 measurements   

 

10.0 to 100℃ 

   

(when using alkaline batteries) 

Resolution 

0.1% Brix / 0.1℃ 

  International   

IP65 

Accuracy 

±

0.2% Brix / 

±

1℃ 

  Protection class 

 

Automatic temperature 
compensation range 

10 to 100℃ 

  Dimensions   

and weight 

55 (W) x 31 (D) x 109 (H)mm,   
100g (main unit only) 

Ambient temperature range  10 to 40℃ 

   

 

 
 
 

The product is in conformity with the requirements of the EMC Directive 2004/108/EC. 

Patent Granted in Japan, United States, Germany, China and Taiwan. 

 

 

Headquarters: The Front Tower Shiba Koen, 
23rd Floor 2-6-3 Shiba-koen, Minato-ku, 
Tokyo 105-0011, Japan 
TEL: 81-3-3431-1943    [email protected] 
http://www.atago.net/ 

 

TEL: 1-425-637-2107 
[email protected] 

 

TEL: 91-22-2854-4915 / 4071-3232 
[email protected] 

 

TEL: 66-21948727-9 ,66-21171549 
[email protected] 

 

TEL: 55 16 3913-8400 
[email protected] 

 

TEL: 39 02 36557267 
[email protected] 

 

TEL: 86-20-38108256    [email protected] 

 

TEL: 7-812-777-96-96    [email protected] 

 

TEL: 234-707-558-1552    [email protected] 

1702K Printed in Japan 

Digital Hand-held 

Pocket

 Refractometer 

PAL-LOOP 

Cat.No.3842 

3842-E06 

Instruction Manual

 

 

Parts 

 

 

 

Contents 

 

 

Main unit......... 1 

 

Instruction Manual (this book) .....1 

 

Calibration Report .. 1 

 

AAA batteries ...........2 

AAA alkaline batteries are included. Remove the tape from the battery compartment before inserting the batteries. 

ATAGO instruments are rigorously inspected to ensure each unit meets the highest standards of quality assurance. 

 

Introduction 

 

Thank you for purchasing the instrument. Carefully read and follow all instructions. Keep this manual for future reference. 
 

Safety Instructions 

Read and follow all safety instructions before operating the instrument. Failure to comply with the following instructions may result in personal injury or 
property damage. 

 

 

Ensure safety when handling hazardous materials. Observe precautionary measures and use protective equipment, Be aware of the hazards of such 
chemicals and emergency response guidelines. 

 

ATAGO may not be held liable for any injury or damage arising in connection with handling of hazardous materials during the use of the instrument. 

 

Do not drop the instrument or subject it to strong physical shock. 

 

Do not attempt to repair, modify, or disassemble the instrument. 

 

 

Carefully read this manual to have basic knowledge of the function of each component. 

 

ATAGO is not liable for any loss and damage caused by the measurement and use of this instrument. 

 

Some acids may corrode the glass prism and/or metal sample stage, which may cause erroneous measurements. 

 

Do not use metal tools, such as a spoon, as they may scratch the prism, resulting in erroneous measurements.

 

 

Do not use water above 50℃  to rinse the instrument. 

 

Only use the specified battery type. Observe proper polarities, properly aligning the anodes and cathodes.   

 

Store the instrument away from direct sunlight/heat sources and excessive amounts of dust/debris. 

 

Do not expose the instrument to a rapid change in ambient temperature.   

 

Do not subject the instrument to strong vibration. 

 

Do not subject the instrument to extreme cold temperature. 

 

Do not place the instrument under anything heavy. 

 

Loosen the battery compartment cover for air transportation. 

 

<International Protection Classification IP65> 

 

The instrument is water-resistant, not waterproof, and should not be submerged. 

 

<Chemical Resistance of Body Case> 

 

The body case is made of PBT resin. Do not expose it to water vapor or solvents. See the list of 

Solvents Harmful to Body Case.

 

 

Press to take measurements and 
hold down to turn off the display. 

START button 

Place and remove batteries 
from here. 

Battery compartment 

Sample stage 

Apply water and samples on the glass prism 
located in the center of the sample stage. 

ZERO button 

Press to perform zero-setting. 

Lanyard hole 

Measurement results, prism 
temperature, and remaining battery 
charge are displayed. 
The displayed value is an example. 

LCD 

Отзывы: