Operating Instructions
AT
AG QR-Series
11
Parameters end users
Menu
Line no.
Selection possibilities
Unit
Min.
Max
Factory setting
Time program 5
600
Preselection
-
Mo-Su, Mo-Fr, Sa-Su
Mo-Su, Mo-Fr, Sa-Su
Mo-Su
Only works in
combination
with QAA55,
NOT with OT/
On-Off
601
Mo-Su: 1. Phase On
uu:mm
00:00
24:00
06:00
602
Mo-Su: 1. Phase Off
uu:mm
00:00
24:00
22:00
603
Mo-Su: 2. Phase On
uu:mm
00:00
24:00
--.--
604
Mo-Su: 2. Phase Off
uu:mm
00:00
24:00
--.--
605
Mo-Su: 3. Phase On
uu:mm
00:00
24:00
--.--
606
Mo-Su: 3. Phase Off
uu:mm
00:00
24:00
--.--
616
Default values
-
Yes
No
No
Holidays HC1
641
Preselection
-
Period 1, 2, 3, 4, 5, 6, 7, 8
Period 1
642
Period Start Day / Month
tt.MM
01.01
31.12
--.--
643
Periode End Day / Month
tt.MM
01.01
31.12
--.--
648
Operating level
-
Frost protection, Reduced
Frost protection
Frost protection
Holidays HC2
(When activated)
651
Preselection
-
Period 1, 2, 3, 4, 5, 6, 7, 8
Period 1
652
Period Start Day / Month
tt.MM
01.01
31.12
--.--
653
Periode End Day / Month
tt.MM
01.01
31.12
--.--
658
Operating level
-
Frost protection, Reduced
Frost protection
Frost protection
HC1
710
Comfort setpoint
°C
Value from Line no. 712
35
20.0
712
Reduced setpoint
°C
4
Value from Line no. 710
16.0
714
Frost protection setpoint
°C
4
Value from Line no. 712
10.0
720
Heating curve slope
-
0.10
4.00
1.50
730
Summer/winter heating limit
°C
---/8
30
20
HC 2
(When activated)
1010
Comfort setpoint
°C
Value from Line no. 1012
35
20.0
1012
Reduced setpoint
°C
4
Value from Line no. 1010
16.0
1014
Frost protection setpoint
°C
4
Value from Line no. 1012
10.0
1020
Heating curve slope
-
0.10
4.00
0.8
1030
Summer/winter heating limit
°C
---/8
30
0
DHW
1600
Operating mode
-
Off, On, Eco
Off
1610
Nominal setpoint
°C
Value from Line no. 1612
80
55
1612
Reduced setpoint
°C
8
Value from Line no. 1610
40
Swimming pool
2055
Pool setpoint solar heating
°C
8
80
26
2056
Pool sepoint boiler heating
°C
8
80
22
Boiler
2214
Setpoint manual control
°C
10
90
50
Error
6700
Error message
-
-
-
Indication only
6705
SW Diagnose Code
-
-
-
Indication only
6706
Burner ctrl phase lockout pos
-
-
-