Service Information No. 05/2006
IKP ..5. from -20
Page 15/16
9.0 Service menu
The service menu may be used only by customer service technicians.
9.1
Demo mode "d0"
•
Press SuperCool and On/Off simultaneously for 3 seconds.
•
"d1" or "d0", the SuperCool LED flash.
•
d1
= demo mode is deactivated. To activate the demo mode, press SuperCool.
•
d0
= demo mode is activated. To deactivate the demo mode, press SuperCool.
•
If no change is required, SuperCool must not be pressed, but On/Off.
•
When the demo mode is active, compressor and fans are not activated.
Attention:
The demo mode
cannot
be deactivated by power OFF/ON.
This is possible only via the service menu.
9.2
Service mode "L"
•
Press SuperCool and On/Off simultaneously for 3 seconds.
•
"d1" or "d0", the SuperCool LED flash.
•
Press "Up" once.
•
Press SuperCool, you are now in the service mode.
•
"rd"
flashes.
•
Open and close door.
•
All segments and LEDs are lit.
•
Press all the buttons. Every press of a button is confirmed by a signal tone.
•
2 seconds signal tone. Control panel test concluded - load test active.
•
Display
"L0".
•
All the loads can be individually addressed using "Up" or "Down".
-
L0:
No load addressed
-
L2:
Compressor
-
L5:
LED interior light
-
L7:
Fan (Only IKP 2850)
•
End with On/Off.
IKP 2850 with fan