79
78
INSTALLATION INSTRUCTIONS
gas information
setting up the appliance for other gas types (only HG61/76/91/96)
This appliance has been set up for natural gas. The appliance can be set
up for other gas types and pressures by means of a conversion kit. You can
order the kit from the sales and service organisation. The conversion
instructions are supplied with the kit.
G25/25 mbar
G20/20 mbar
G25/20 mbar
G30/29 mbar
G31/29 mbar
G31/37 mbar
G30/50 mbar
G31/50 mbar
burner type
(kW)
(kW)
(kW)
(kW / g/h)
(kW / g/h)
(kW / g/h)
(kW / g/h)
(kW / g/h)
simmer
1.00
1.00
0.90
0.90 / 65
0.79 / 57
0.90 / 65
1.00 / 72
0.88 / 63
normal
2.00
2.00
1.80
1.60 / 115
1.41 / 101
1.60 / 115
2.00 / 144
1.76 / 127
strong
3.00
3.00
2.70
2.30 / 166
2.02 / 146
2.30 / 166
2.70 / 194
2.38 / 171
super-strong
3.60
3.60
3.60
3.00 / 216
2.64 / 190
3.00 / 216
3.50 / 252
3.08 / 222
wok
4.50
4.50
4.50
3.50 / 252
3.08 / 222
3.50 / 252
4.00 / 288
3.52 / 253
INSTALLATION INSTRUCTIONS
building in
space to be left free around the appliance
A hob generates heat. Leave a sufficient distance between the appliance
and non heat-resistant materials.
The gas hob may only be built in next to one vertical wall.
fastening the hob
Using the clips supplied, secure the hob in the holes that have been
created.
min. 600 mm (HG41/HG61)
min. 750 mm (HG76)
min. 900 mm (HG91/HG96)
min. 650 mm
min. 450 mm
min. 100 mm
min. 100 mm