Asycube 50 & 80
Operating Manual
©
Copyright Asyril S.A.
000.100.501
Version: A1
Operating Manual - Asycube 50 & 80
18/45
Power connection
WARNING !
-
Before supplying power to the Asycube, check the nominal voltage.
-
Ensure that the power cable is connected to the asycube before switching on
-
Always turn off the power supply of the asycube before disconnecting the power
cable.
-
Make sure to connect the 0V and the 24V according to the table. An incorrect
connection can damage the asycube.
Power
Signal description
(1)
24VDC PELV S-Power
(2)
0V GND S-Power
(3)
24VDC PELV Power
(4)
0V GND Power
(5)
EARTH
Connector type (on asycube side) :
M16, 5 Poles, male
In case of all functions working
simultaneously (vibration, backlight,
hopper), the current increases to 6A
Characteristic
Value
Voltage
+24V DC +
5%
Current Power
5 A max.
Current S-Power
1 A max.
Figure 2-8 : power connection
(1)
(2)
(3)
(4)
(5)