Description
v1.2
FO 32.03.118
Operating Manual
Asycube Largo A5
- Asyril SA
18/45
Communication
2.4.3.
The communication with the asycube is
established
by
a
standard
Ethernet
communication via RJ45 port
(A)
Characteristic
Value
Default IP
address
192.168.127.254
Default subnet
mask
255.255.255.0
Port
4001
MAC address
Can be read by
ARP request
For more information on the procedure to
restore the default IP address, please see
chapter 4.4.2.
Figure 2-10 : Ethernet connection RJ45
Backlight Synchronization
2.4.4.
A standard M8 three-pins female cable
enables to synchronize camera acquisition
and Asycube backlight illumination, it must
be connected as follows :
Pin
Signal
(1)
Not wired
(3)
0V GND
(4)
+24 V pulse
(illumination synch.)
Connector type (on asycube side) :
M8, 3P, male
Figure 2-11 : Backlight synchronization
NOTE :
The Asycube Backlight illumination time corresponds to the length of the pulse signal.
(A)
(3)
(4)
(1)