
2-27
ASUS RS720-E7-RS24 Series
To replace a redundant power supply module:
1.
Select the redundant power supply
module that you wish to replace.
2.
Press the lock (A) then pull the power
supply module via the metal pull handle
(B). As you remove the power supply
module from the bay, use your other
hand to support the power supply
module.
3. Prepare the replacement power supply
module.
Ensure to remove the plastic covering
the power supply module before
installing the module.
4. Carefully insert the replacement power
supply module all the way into the bay.
5. Press the lock (C) then push the power
supply module until it is securely seated
in place (D).
Replacing a redundant power supply module
A
B
C
D
Содержание RS720-E7-RS24-EG
Страница 1: ...2U Rackmount Server RS720 E7 RS24 EG User Guide ...
Страница 36: ...Chapter 2 Hardware setup 2 14 Sixteen 16 DIMMs population G H A B D C F E G H A B D C F E ...
Страница 50: ...Chapter 2 Hardware setup 2 28 ...
Страница 162: ...6 38 Chapter 6 RAID configuration ...
Страница 198: ...7 36 Chapter 7 Driver installation ...
Страница 202: ...A 4 Appendix ...