ASUS RS700-E6/RS4
6-31
Select a destination disk with the same size as the original hard disk.
[
DEGRADED VOLUME DETECTED
]
[
↑↓
]-Previous/Next [ENTER]-Select [ESC]-Exit
"Degraded" volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XX.XGB
6.3.7
Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system
displays the status of the RAID volume as “
Degraded
” during POST. You can
rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. At the prompt, press <Ctrl> + <I> to enter the Intel Matrix Storage Manager
option ROM utility.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to
rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select
the destination disk or press <ESC> to exit.
6.3.6
Exiting the Intel
®
Matrix Storage Manager
To exit the utility
1. From the utility main menu, select
5. Exit
, and then press <Enter>. The
following warning message appears.
2. Press <Y> to exit or press <N> to return to the utility main menu.
Are you sure you want to exit? (Y/N):
[
CONFIRM EXIT
]
Содержание RS700-E6 ERS4
Страница 1: ...1U Rackmount Server RS700 E6 RS4 User Guide 1 2 ...
Страница 32: ...Chapter 2 Hardware setup 2 14 ...
Страница 38: ...Chapter 4 Motherboard information 4 2 4 1 Motherboard layout ...
Страница 84: ...5 36 Chapter 5 BIOS setup ...
Страница 118: ...6 34 Chapter 6 RAID configuration ...