background image

ASUS RS700-E6/RS4

4-3

Layout contents

Jumpers

Page

1. 

Clear RTC RAM (CLRTC1)

4-4

2. 

VGA controller setting (3-pin VGA_SW1)

4-5

3. 

LAN controller setting (3-pin LAN_SW1, LAN_SW2)

4-5

4. 

Force BIOS recovery setting (3-pin RECOVERY1)

4-6

5. 

IPMI setting (3-pin IPMI_SEL1)

4-6

6. 

iBTN RAID setting (3-pin IBTN_SEL1)

4-7

7. 

RAID configuration utility selection (3-pin RAID_SEL1)

4-7

8. 

DDR3 voltage setting (4-pin LVDDR3_SEL1/2)

4-8

Internal connectors

Page

1. 

USB connector (4-pin USB7)

4-9

2. 

Serial port connector (10-1 pin COM2)

4-9

3. 

LPC debug card connector (14-1 pin LPC1)

4-10

4. 

Baseboard Management Controller (BMC) connector 

 

 

(14-pin BMC_FW1)

4-10

Internal LEDs

Page

1. 

Standby power LED

4-11

2. 

Baseboard Management Controller LED (BMC_LED1)

4-11

3. 

Diagnose LEDs 

4-12

Содержание RS700-E6 ERS4

Страница 1: ...1U Rackmount Server RS700 E6 RS4 User Guide 1 2 ...

Страница 2: ...tion of business and the like even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product Specifications and information contained in this manual ae furnished for informational use only and are subject to change at any time without notice and should not be construed as a commitment by ASUS ASUS assumes no responsibility or liability f...

Страница 3: ...rdware setup 2 1 Central Processing Unit CPU 2 2 2 1 1 Installing the CPU 2 2 2 1 2 Installing the CPU heatsink 2 5 2 2 System memory 2 6 2 2 1 Overview 2 6 2 2 2 Memory configurations 2 6 2 3 Hard disk drives 2 8 2 4 Expansion slot 2 9 2 4 1 Installing an expansion card to the riser card bracket 2 9 2 4 2 Installing ASUS PIKE RAID card optional 2 10 2 4 3 Configuring an expansion card 2 11 2 5 In...

Страница 4: ...4 Menu items 5 7 5 2 5 Sub menu items 5 7 5 2 6 Configuration fields 5 7 5 2 7 Pop up window 5 7 5 2 8 Scroll bar 5 7 5 2 9 General help 5 7 5 3 Main menu 5 8 5 3 1 System Time 5 8 5 3 2 System Date 5 8 5 3 3 SATA1 6 5 8 5 3 4 IDE Configuration 5 10 5 3 5 AHCI Configuration 5 11 5 3 6 System Information 5 12 5 4 Advanced menu 5 13 5 4 1 CPU Configuration 5 13 5 4 2 Chipset Configuration 5 16 5 4 3...

Страница 5: ... Utility 6 4 6 2 1 Creating a RAID set 6 5 6 2 2 Adding or viewing a RAID configuration 6 11 6 2 3 Initializing the virtual drives 6 12 6 2 4 Rebuilding failed drives 6 16 6 2 5 Checking the drives for data consistency 6 18 6 2 6 Deleting a RAID configuration 6 21 6 2 7 Selecting the boot drive from a RAID set 6 22 6 2 8 Enabling WriteCache 6 23 6 3 Intel Matrix Storage Manager Option ROM Utility ...

Страница 6: ...AID controller driver 7 5 7 2 Intel chipset device installation 7 12 7 3 LAN driver installation 7 14 7 4 VGA driver installation 7 17 7 5 Management applications and utilities installation 7 19 7 5 1 Running the support DVD 7 19 7 5 2 Drivers menu 7 19 7 5 3 Utilities menu 7 20 7 5 4 Make disk menu 7 20 7 5 5 Contact information 7 20 ...

Страница 7: ...ncrease the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Department of Communications Statement This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Rad...

Страница 8: ...efore operating the server carefully read all the manuals included with the server package Before using the server make sure all cables are correctly connected and the power cables are not damaged If any damage is detected contact your dealer as soon as possible To avoid short circuits keep paper clips screws and staples away from connectors slots sockets and circuitry Avoid dust humidity and temp...

Страница 9: ...nents 3 Chapter 3 Installation options This chapter describes how to install the optional components and devices into the barebone server 4 Chapter 4 Motherboard information This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors 5 Chapter 5 BIOS information This chapter tells how to change system settings through the BIOS Setup menus and describe...

Страница 10: ... emphasize a word or a phrase Key Keys enclosed in the less than and greater than sign means that you must press the enclosed key Example Enter means that you must press the Enter or Return key Key1 Key2 Key3 If you must press two or more keys simultaneously the key names are linked with a plus sign Example Ctrl Alt D Command Means that you must type the command exactly as shown then supply the re...

Страница 11: ...ASUS RS700 E6 RS4 1 2 This chapter describes the general features of the server including sections on front panel and rear panel specifications Chapter 1 Product introduction ...

Страница 12: ... 1 x SAS SATA2 Backplane ASUS BP4LX2 R12A 3 x PCI Riser Card ASUS RE16L R12A RE16F R12A RE8R R12A 1 x Front I O Board ASUS FPB AR14 1 x Redundant Power Supply Power Distribution Board ASUS PDB R12A 3 x Bridge Card ASUS CF R12A A CF R12A S CP R12A 7 x System Fans 40mm x 56mm 1 x Air Duct Accessories 1 x RS700 E6 RS4 User s Guide 1 x ASUS ASWM 2 0 User s Guide 1 x RS700 E6 RS4 Support CD including A...

Страница 13: ...M Unbuffered DIMM with ECC Memory Size 1GB 2GB 4GB and 8GB Expansion Slots Total PCI PCI X PCI E Slots 3 Slot Type 1 x PCIe 2 0 x16 slot x16 link Full Height Half Length PCIe1 1 x PCIe 2 0 x16 slot x8 link Full Height Half Length PCIe2 1 x PCIe 2 0 x8 slot x8 link Low profile Half Length PCIe3 Additional Slot 1 x PIKE Slot for storage enhancement Storage SATA Controller Intel ICH10R 6 x SATA2 300M...

Страница 14: ...0 32 64 bit SuSE Linux Enterprise Server 10 32 64 bit Subject to change without any notice Anti virus Software Optional CA eTrust 7 1 anti virus software Management Solution Out of Band Remote Hardware Optional ASMB4 iKVM for KVM over IP support Software ASUS ASWM 2 0 Dimension HH x WW x DD 687 8mm x 444mm x 43 4mm Net Weight Kg CPU DRAM HDD not includeed 15 Kg Power Supply 770W 80 1 1 Redundant P...

Страница 15: ... socket and rear fans The middle part includes the I O shield with openings for the rear panel connectors on the motherboard The ports for the PS 2 keyboard PS 2 mouse USB VGA and Gigabit LAN do not appear on the rear panel if motherboard is not present 1 2 Hot swap HDD bays Optical drive Rack screw Rack screw USB ports LAN2 LED HDD Access LED LAN1 LED Message LED Power button Power LED Location s...

Страница 16: ... DVD ROMs fit the optical drive bay 1 PCI Express slot Riser Cards 2 CPU heatsinks 3 Power fans 4 ASUS Z8PS D12 1U server board 5 Power supply 6 System fans 7 SATA SAS backplane hidden 8 Hot swap HDD tray 1 Connects to SATA1 port Port 0 9 Hot swap HDD tray 2 Connects to SATA2 port Port 1 10 Hot swap HDD tray 3 Connects to SATA3 port Port 2 11 Hot swap HDD tray 4 Connects to SATA4 port Port 3 12 Fr...

Страница 17: ...stem is normal no incoming event ASWM indicates a HW monitor event Location LED OFF ON Normal status Location switch is pressed Press the location switch again to turn off LAN LEDs OFF Blinking ON No LAN connection LAN is transmitting or receiving data LAN connection is present 1 7 2 LAN RJ 45 LEDs ACT LINK LED SPEED LED Status Description Status Description OFF No link OFF 10 Mbps connection GREE...

Страница 18: ... SATAII SAS HDD not present RED Blinking 1 HDD has failed and should be swapped immediately slow blinking 2 times sec 2 RAID rebuilding fast blinking 10 times sec HDD Activity LED GREEN Blinking Read write data from into the SATAII SAS HDD When using ICH10R Intel Matrix Storage RAID HDD LEDs will not work 1 2 HDD Status LED HDD Activity LED ...

Страница 19: ...ASUS RS700 E6 RS4 1 2 This chapter lists the hardware setup procedures that you have to perform when installing or removing system components Chapter 2 Hardware setup ...

Страница 20: ...f the PnP cap is missing or if you see any damage to the PnP cap socket contacts motherboard components ASUS will shoulder the cost of repair only if the damage is shipment transit related Keep the cap after installing the motherboard ASUS will process Return Merchandise Authorization RMA requests only if the motherboard comes with the cap on the LGA1366 socket The product warranty does not cover ...

Страница 21: ... load lever with your thumb A then move it to the left B until it is released from the retention tab A B Load lever Retention tab 3 Lift the load lever in the direction of the arrow to a 135º angle 4 Lift the load plate with your thumb and forefinger to a 100º angle Load plate 4 3 5 Remove the PnP cap from the CPU socket PnP cap ...

Страница 22: ...y CPU notch 7 Apply several drops of thermal paste to the exposed area of the CPU that the heatsink will be in contact with ensuring that it is spread in an even thin layer Some heatsinks come with pre applied thermal paste If so skip this step The thermal paste is toxic and inedible If it gets into your eyes or touches your skin ensure to wash it off immediately and seek professional medical help...

Страница 23: ...ace the heatsink on top of the installed CPU making sure that the four screws on the heatsink align with the nuts on the support plate 2 Use a Phillips screwdriver to tighten the four heatsink screws in a diagonal sequence 1 2 2 2 2 A B B A 3 Repeat step 1 and 2 to install the other heatsink if you have installed a second CPU 4 Turn up the bridge board cover near the system fan Position the airduc...

Страница 24: ... the system will not boot if only one DIMM is installed in DIMM slot A2 B2 or C2 for CPU1 or D2 E2 or F2 for CPU2 Follow the table above for recommended memory configuration 1 2 3 4 5 6 12 11 10 9 8 7 1 2 3 4 5 6 DIMM_A2 DIMM_A1 DIMM_B2 DIMM_B1 DIMM_C2 DIMM_C1 7 8 9 10 11 12 DIMM_D2 DIMM_D1 DIMM_E2 DIMM_E1 DIMM_F2 DIMM_F1 Recommended CPU2 memory configuration Mode Sockets DIMM_D2 DIMM_D1 DIMM_E2 D...

Страница 25: ...hannel for the dual channel or triple channel configuration Any excess memory from the higher sized channel is then mapped for single channel operation Due to the memory address limitation on 32 bit Windows OS when you install 4GB or more memory on the motherboard the actual usable memory for the OS can be about 3GB or less For effective use of memory we recommend that you install a 64 bit Windows...

Страница 26: ...1 to 5 if you wish to install a second SATAII SAS drive To install a hot swap SATAII SAS HDD 1 Release a drive tray by pushing the spring lock to the right and then pulling the tray lever outward The drive tray ejects slightly after you pull out the lever 2 Firmly hold the tray lever and pull the drive tray out of the bay 2 1 3 Place a SATAII SAS hard disk drive on the tray and then secure it with...

Страница 27: ... Install a PCI Express card to the bracket as shown and then secure the card with a screw 3 Align the riser card bracket with the cards to the PCI Express slot on the motherboard 4 Press the riser card bracket until the golden connectors completely fit the slot and the bracket aligns with the rear panel 5 Connect the cable s to the card if applicable 1 Firmly hold the riser card bracket and then d...

Страница 28: ...ocate the PIKE RAID card slot on the motherboard 2 Turn up the bridge board cover near the system fan 3 Remove the pre installed ASUS CF R12A A bridge board 2 3 4 Insert the RAID card into the PIKE RAID card slot Ensure that it is completely seated on the PIKE RAID card slot 5 Install the bundled ASUS CF R12A S bridge board 6 Recover the bridge board cover 5 4 ...

Страница 29: ...vers for the expansion card These IRQs are usually available for ISA or PCI devices IRQ Priority Standard function 0 1 System Timer 1 2 Keyboard Controller 2 Programmable Interrupt 3 11 Communications Port COM2 4 12 Communications Port COM1 5 13 6 14 Floppy Disk Controller 7 15 8 3 System CMOS Real Time Clock 9 4 ACPI Mode when used 10 5 IRQ Holder for PCI Steering 11 6 IRQ Holder for PCI Steering...

Страница 30: ...LAN or Serial Port such as CPU and memory utilization storage capacity and networking transfer rate Advanced server management functions including remote power on off reset remote control via SOL Serial over LAN and remote SEL system event log reading when the system is out of band Support Dynamic Host Configuration Protocol DHCP which avoids manually assigning IP address by setting DHCP mode to r...

Страница 31: ...y redundancy power backup 3 If you need to replace a failed power supply unit hold the PSU lever and press the PSU latch Firmly pull the failed PSU out of the server chassis 1 2 To install the second power supply unit 1 Locate the power supply unit on the rear panel Press the latch on the dummy power supply module and pull it out of the server chassis 1 2 2 Firmly push the second power supply unit...

Страница 32: ...Chapter 2 Hardware setup 2 14 ...

Страница 33: ...ASUS RS700 E6 RS4 1 2 This chapter describes how to install the optional components and devices into the barebone server Chapter 3 Installation options ...

Страница 34: ...r rails to the two sides of the server chassis 2 Follow the directions in the figure to attach the rear inner rails to the two sides of the server chassis 3 Secure the inner rails to the server chassis with four 4 screws 3 1 Rack rails assembly If you have the rackmount rail kit it contains two pairs of rails one pair for each side of the barebone system Follow the illustrations below for rackmoun...

Страница 35: ... on the rack and secure both the front end and the rear end of the rail with two screws each 7 Repeat step 4 6 to assemble and attach the outer rail on the other side of the rack Ensure that it is level with the previously installed rack rail 8 Align the inner rails on the server with the outer rails on the rack 9 Push the server all the way into the rack 10 Secure the server to the rack ...

Страница 36: ...e rear inner rails Remove the server from the rack 3 2 Removing the Server from the rack Follow the illustrations below to remove the server from the rack 1 Release the rack screws and pull out the server from the rack Push the front latches on the two sides to release the front inner rails ...

Страница 37: ...ASUS RS700 E6 RS4 1 2 This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors Chapter 4 Motherboard Info ...

Страница 38: ...Chapter 4 Motherboard information 4 2 4 1 Motherboard layout ...

Страница 39: ...AID setting 3 pin IBTN_SEL1 4 7 7 RAID configuration utility selection 3 pin RAID_SEL1 4 7 8 DDR3 voltage setting 4 pin LVDDR3_SEL1 2 4 8 Internal connectors Page 1 USB connector 4 pin USB7 4 9 2 Serial port connector 10 1 pin COM2 4 9 3 LPC debug card connector 14 1 pin LPC1 4 10 4 Baseboard Management Controller BMC connector 14 pin BMC_FW1 4 10 Internal LEDs Page 1 Standby power LED 4 11 2 Base...

Страница 40: ...e computer and unplug the power cord 2 Move the jumper cap from pins 1 2 default to pins 2 3 Keep the cap on pins 2 3 for about 5 10 seconds then move the cap back to pins 1 2 3 Plug the power cord and turn ON the computer 4 Hold down the Del key during the boot process and enter BIOS setup to re enter data Except when clearing the RTC RAM never remove the cap on CLRTC jumper default position Remo...

Страница 41: ...to enable or disable the onboard VGA controller Set to pins 1 2 to activate the VGA feature 3 LAN controller setting 3 pin LAN_SW1 LAN_SW2 These jumpers allow you to enable or disable the onboard Intel 82574L Gigabit LAN1 2 controller Set to pins 1 2 to activate the Gigabit LAN feature ...

Страница 42: ...et the jumper to pins 2 3 3 Insert the USB flash drive and then turn on the system to update the BIOS 4 Shut down the system 5 Set the jumper back to pins 1 2 6 Turn on the system Use the AFUDOS uitility version 3 12 or later to flash the BIOS 5 IPMI setting 3 pin IPMI_SEL1 This jumper allows you to use the IPMI feature through the dedicated LAN or share LAN Place the jumper caps on pins 1 2 if yo...

Страница 43: ...ed Intel ICH10R SATA controller LSI Logic MPT Setup Utility is available only when you install a PIKE RAID card LSI Mega RAID 5 fucntion is available only when you place the iBTN to I_BTN1 slot and install an optional ASUS PIKE RAID card 7 RAID configuration utility selection 3 pin RAID_SEL1 This jumper allows you to select the RAID configuration utility to use when you create disk arrays Place th...

Страница 44: ...llow you to select DDR3 DIMM voltage settings Place the jumper caps on pins 1 2 if you want to control DDR3 voltage by BIOS settings default Place the jumper caps on pins 2 3 to force the DDR3 DIMMs to run at 1 2V Or you can place the jumper caps on pins 3 4 to force the DDR3 DIMMs to run at 1 35V ...

Страница 45: ...or complies with the USB 2 0 specification that supports up to 480 Mbps connection speed 2 Serial port connector 10 1 pin COM2 This connector is for a serial COM port Connect the serial port module cable to this connector then install the module to a slot opening at the back of the system chassis The serial port module is purchased separately ...

Страница 46: ...1 This connector is for a LPC debug card The LPC debug card is purchased separately 4 Baseboard Management Controller BMC connector 14 pin BMC_FW1 This is an interface used to plug in an ASMB4 SOL or ASMB4 iKVM management device The ASMB4 management device is purchased separately ...

Страница 47: ... cable before removing or plugging in any motherboard component The illustration below shows the location of the onboard LED 2 Baseboard Management Controller LED BMC_LED1 The BMC LED works with the ASUS ASMB4 management device and indicates its initiation status When the PSU is plugged and the system is OFF ASUS ASMB4 management device starts system initiation for about one 1 minute The BMC LED b...

Страница 48: ...d information 4 12 3 Diagnose LEDs These red LEDs check key components in sequence during motherboard booting process If an error is found the LED next to the error device will continue lighting until the problem is solved ...

Страница 49: ...ASUS RS700 E6 RS4 1 2 This chapter tells how to change the system settings through the BIOS Setup menus Detailed descriptions of the BIOS parameters are also provided Chapter 5 BIOS setup ...

Страница 50: ... gets corrupted during the updating process Copying the current BIOS To copy the current BIOS file using the AFUDOS utility Ensure that the USB flash drive is not write protected and has at least 2048 KB free space to save the file The succeeding BIOS screens are for reference only The actual BIOS screen displays may not be the same as shown 1 Copy the AFUDOS utility afudos exe from the motherboar...

Страница 51: ...re Update Utility Version 1 19 ASUS V2 07 03 11 24BB Copyright C 2002 American Megatrends Inc All rights reserved WARNING Do not turn off power during flash BIOS Reading file done Reading flash done Advance Check Erasing flash done Writing flash 0x0008CC00 9 The utility verifies the file and then starts updating the BIOS file DO NOT shut down or reset the system while updating the BIOS to prevent ...

Страница 52: ...over the BIOS using ASUS CrashFree BIOS 3 1 Insert the USB flash disk that contains the BIOS file to the USB port 2 Turn on the system 3 The utility will automatically checks the devices for the BIOS file When found the utility reads the BIOS file and starts flashing the corrupted BIOS file 4 Restart the system after the utility completes the updating process DO NOT shut down or reset the system w...

Страница 53: ... Press Del during the Power On Self Test POST to enter the Setup utility otherwise POST continues with its test routines If you wish to enter Setup after POST restart the system by pressing Ctrl Alt Delete or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup program is design...

Страница 54: ...for that particular menu Use the navigation keys to select items in the menu and change the settings 5 2 1 BIOS menu screen Some of the navigation keys differ from one screen to another v02 61 C Copyright 1985 2008 American Megatrends Inc BIOS SETUP UTILITY Main Advanced Server Boot Exit Use ENTER TAB or SHIFT TAB to select a field Use or to configure system Date Select Screen Select Item Change F...

Страница 55: ...p up window with the configuration options for that item 5 2 8 Scroll bar A scroll bar appears on the right side of a menu screen when there are items that do not fit on the screen Press the Up Down arrow keys or Page Up Page Down keys to display the other items on the screen 5 2 9 General help At the top right corner of the menu screen is a brief description of the selected item v02 61 C Copyrigh...

Страница 56: ...o configure system Date System Time 13 44 30 System Date Tue 11 04 2008 SATA 1 ST3160812AS SATA 2 Not Detected SATA 3 Not Detected SATA 4 Not Detected SATA 5 Not Detected SATA 6 TSSTcorp CDDVDW TS IDE Configuration AHCI Configuration System Information Select Screen Select Item Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit v02 61 C Copyright 1985 2008 American Megatrends...

Страница 57: ... data multi sectors transfers When set to Auto the data transfer from and to the device occurs multiple sectors at a time if the device supports multi sector transfer feature When set to Disabled the data transfer from and to the device occurs one sector at a time Configuration options Disabled Auto PIO Mode Auto Allows you to select the data transfer mode Configuration options Auto 0 1 2 3 4 DMA ...

Страница 58: ...set this item to AHCI The AHCI allows the onboard storage driver to enable advanced Serial ATA features that increases storage performance on random workloads by allowing the drive to internally optimize the order of commands If you want to use LSI MegaRAID or the Intel Matrix Storage Technology configuration from the Serial ATA hard disk drives set this item to RAID Hard Disk Write Protect Disabl...

Страница 59: ...on options 0 5 10 15 20 25 30 35 SATA Port1 6 XXXX Displays the status of auto detection of SATA devices 5 3 5 AHCI Configuration This menu is the section for AHCI configuration BIOS SETUP UTILITY Main AHCI Settings AHCI CD DVD Boot Time out 35 SATA Port1 Not Detected SATA Port2 Not Detected SATA Port3 Not Detected SATA Port4 Not Detected SATA Port5 Not Detected SATA Port6 Not Detected Some SATA C...

Страница 60: ...unt 1 System Memory Usable Size 1024MB System Memory Information AMIBIOS Displays the auto detected BIOS information Processor Displays the auto detected CPU specification System Memory Displays the auto detected system memory System Memory Information Displays system memory information BIOS SETUP UTILITY Main AMIBIOS CPU1 Memory Configuration CPU2 Memory Configuration CPU1 2 Memory Configuration ...

Страница 61: ...an Megatrends Inc BIOS SETUP UTILITY Advanced Configure advanced CPU settings Module Version 3F 11 Manufacturer Intel Brand String Genuine Intel R CPU 0000 2 67GHz Frequency 2 66GHz BCLK Speed 133MHz Cache L1 128 KB Cache L2 1024 KB Cache L3 8192 KB Ratio Status Unlocked Min 12 Max 20 Ratio Actual Value 20 CPUID 106A2 Ratio CMOS Setting Auto C1E Support Enabled Hardware Prefetcher Enabled Adjacent...

Страница 62: ...a hardware platform to run multiple operating systems separately and simultaneously enabling one system to virtually function as several systems Configuration options Disabled Enabled CPU TM Function Enabled This function enables the overheated CPU to throttle the clock speed to cool down Configuration options Disabled Enabled Execute Disable Bit Capability Enabled Allows you to enable or disable ...

Страница 63: ...ion under C3 state Configuration options Disabled ACPI C2 ACPI C3 C6 7 State Enabled Allows you to select the CPU action under C6 and C7 state Configuration options Disabled Enabled C State package limit setting Auto This item appears only when you set the Intel R C STATE Tech item to Enabled We recommend that you set this item to Auto for BIOS to automatically detect the C State mode supported by...

Страница 64: ...opyright 1985 2008 American Megatrends Inc BIOS SETUP UTILITY Advanced CPU Bridge Chipset Configuration CPU REVISION B0 Current CSI Frequency 6 400GT Current Memory Frequency 1066 Mhz CSI Links Speed Full Speed CSI Frequency Auto Memory Frequency Auto Memory Mode Independent Memory ECC Function Enabled Double Rate Refresh Auto Demand Scrubbing Enabled Patrol Scrubbing Disabled NUMA Aware Auto Page...

Страница 65: ...dent Allows you to set Memory channel mode Configuration options Independent Channel Mirroring Lockstep Sparing Memory ECC Function Enabled Allows you to enable or disable the memory ECC function Configuration options Disabled Enabled Double Rate Refresh Auto Configuration options Disabled Auto Demand Scrubbing Enabled Configuration options Disabled Enabled Patrol Scrubbing Disabled Configuration ...

Страница 66: ...ds Inc BIOS SETUP UTILITY Advanced CPU Bridge Chipset Configuration USB Functions 12 USB Ports USB Port Configure 8 4 USB Ports USB 2 0 Controller Enabled HDA Controller Enabled SMBUS Controller Enabled SLP_S4 Min Assertion Width 1 to 2 seconds PCIE Ports Configuration PCIE Port 0 Auto PCIE Port 1 Auto PCIE Port 2 Auto PCIE Port 3 Auto PCIE Port 4 Auto PCIE Port 5 Auto PCIE High Priority Port Disa...

Страница 67: ...orts Configuration options Enabled Disabled HDA Controller Enabled Allows you to enable or disable the High Definition Audio controller Configuration options Enabled Disabled SMBUS Controller Enabled Allows you to enable or disable the SMBUS controller Configuration options Enabled Disabled SLP_S4 Min Assertion Width 1 to 2 seconds Configuration options 4 to 5 seconds 3 to 4 seconds 2 to 3 seconds...

Страница 68: ...ntel VT d Configuration Intel VT d Disabled Allows you to enable or disable the Intel Virtualization Technology for Directed I O Configuration options Disabled Enabled BIOS SETUP UTILITY Advanced Intel VT d Disabled Options Disabled Enabled v02 61 C Copyright 1985 2008 American Megatrends Inc BIOS SETUP UTILITY Advanced Legacy Device Configuration Serial Port1 Address 3F8 IRQ4 Serial Port2 Address...

Страница 69: ...480Mbps or FullSpeed 12Mbps Configuration options FullSpeed HiSpeed BIOS EHCI Hand Off Enabled Enables or disables the BIOS EHCI hand off support Configuration options Disabled Enabled Hotplug USB FDD Support Auto Allows you to configure the Hotplug USB FDD support Configuration options Disabled Enabled Auto 5 4 4 USB Configuration v02 61 C Copyright 1985 2008 American Megatrends Inc BIOS SETUP UT...

Страница 70: ...ces not required for boot Configuration options No Yes Onboard LAN1 2 Boot PXE Allows you to configure the onboard LAN1 2 boot mode Configuration Disabled PXE iSCSI v02 61 C Copyright 1985 2008 American Megatrends Inc BIOS SETUP UTILITY Advanced Advanced PCI PnP Settings WARNING Setting wrong values in below sections may cause system to malfunction Plug And Play O S No Onboard LAN1 Boot PXE Onboar...

Страница 71: ...ll while the computer is in Soft off mode Configuration options Disabled Enabled Resume On RTC Alarm Disabled Allows you to enable or disable RTC to generate a wake up event Configuration options Disabled Enabled The following items appear only when the Resume On RTC Alarm item is set to Enabled RTC Alarm Date 15 To set the alarm date highlight this item and press the or key to make the selection ...

Страница 72: ...to confirm the change Clear Event Log Press the ENTER key to clear all system events Select Ok to confirm the change v02 61 C Copyright 1985 2008 American Megatrends Inc BIOS SETUP UTILITY Advanced Event Logging details View Event Log Mark all events as read Clear Event Log Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit View all unread events on the Eve...

Страница 73: ...t Item Change Option F1 General Help F10 Save and Exit ESC Exit Options Disabled Enabled CPU1 2 Temperature xxxºC xxxºF TR1 2 Temperature xxxºC xxxºF The onboard hardware monitor automatically detects and displays the motherboard component and CPU temperatures Select Ignored if you do not wish to display the detected temperatures FRNT_Fan1 2 3 4 5 6 7 Speed xxxxRPM or Ignored N A The onboard hardw...

Страница 74: ...I APIC Support Enabled Allows you to enable or disable the Advanced Configuration and Power Interface ACPI support in the Advanced Programmable Interrupt Controller APIC When set to Enabled the ACPI APIC table pointer is included in the RSDT pointer list Configuration options Disabled Enabled BIOS AML ACPI table Enabled Allows you to include the BIOS AML exchange table pointer to X RSDT pointer li...

Страница 75: ...Wakeup From S3 S4 Disabled Allows you to enable or disable the USB device wakeup from S3 S4 feature Configuration options Disabled Enabled High Performance Event Timer Disabled Allows you to enable or disable the High Performance Event Timer feature Configuration options Disabled Enabled HPET Memory Address FED00000h THis item appears only when you enabled the High Performance Event Timer item Con...

Страница 76: ...og BMC Watch Dog Timer Action Disabled InPut for Set LAN Configuration command See IPMI 1 5 Spec table 19 1 Note Each question in this group may take considerable amount of time 5 5 1 IPMI Configuration Set LAN1 3 Configuration BIOS SETUP UTILITY Server LAN1 Configuration Current IP address in BMC Could Not Read BMC Current Subnet Mask in BMC Could Not Read BMC Current Gateway Address in BMC Could...

Страница 77: ...Down Power Cycle 5 5 2 Remote Access Configuration The items in this menu allows you to configure the Remote Access features Select an item then press Enter to display the configuration options BIOS SETUP UTILITY Server Configure Remote Access type and parameters Remote Access Enabled Serial port number COM2 Base Address IRQ 2F8h 3 Serial Port Mode 57600 8 n 1 Flow Control Hardware Redirection Aft...

Страница 78: ...ons None Hardware Software Redirection After BIOS POST Disabled Sets the redirection mode after the BIOS Power On Self Test POST Some operating system may not work when set to Always Configuration options Disabled Boot Loader Always Terminal Type VT UTF8 Allows you to select the target terminal type Configuration options ANSI VT100 VT UTF8 VT UTF8 Combo Key Support Enabled This item appears only w...

Страница 79: ... Boot Device Priority Boot Settings Configuration Security Select Screen Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit Specifies the Boot Device Priority sequence A virtual floppy disk drive Floppy Drive B may appear when you set the CD ROM drive as the first boot device v02 61 C Copyright 1985 2008 American Megatrends Inc BIOS SETUP UTILITY Boot Boot Device Priorit...

Страница 80: ...Wait For F1 If Error Enabled When set to Enabled the system waits for the F1 key to be pressed when error occurs Configuration options Disabled Enabled Hit DEL Message Display Enabled When set to Enabled the system displays the message Press DEL to run Setup during POST Configuration options Disabled Enabled Interrupt 19 Capture Enabled When set to Enabled this function allows the option ROMs to t...

Страница 81: ...d when prompted The message Password Installed appears after you successfully set your password To change the supervisor password follow the same steps as in setting a user password To clear the supervisor password select the Change Supervisor Password then press Enter The message Password Uninstalled appears If you forget your BIOS password you can clear it by erasing the CMOS Real Time Clock RTC...

Страница 82: ...word this item shows Installed To set a User Password 1 Select the Change User Password item and press Enter 2 On the password box that appears type a password composed of at least six letters and or numbers then press Enter 3 Confirm the password when prompted The message Password Installed appears after you set your password successfully To change the user password follow the same steps as in se...

Страница 83: ...for a confirmation before exiting Discard Changes This option allows you to discard the selections you made and restore the previously saved values After selecting this option a confirmation appears Select YES to discard any changes and load the previously saved values Load Setup Defaults This option allows you to load the default values for each of the parameters on the Setup menus When you selec...

Страница 84: ...5 36 Chapter 5 BIOS setup ...

Страница 85: ...ASUS RS700 E6 RS4 1 2 This chapter provides instructions for setting up creating and configuring RAID sets using the available utilities Chapter 6 RAID configuration ...

Страница 86: ...n provides data protection and increases fault tolerance to the entire system Use two new drives or use an existing drive and a new drive for this setup The new drive must be of the same size or larger than the existing drive RAID 10 is data striping and data mirroring combined without parity redundancy data having to be calculated and written With the RAID 10 configuration you get all the benefit...

Страница 87: ...ction on page 4 7 for details 6 1 4 Setting the RAID item in BIOS You must enable the RAID function in the BIOS Setup before creating RAID set s using SATA HDDs To do this 1 Enter the BIOS Setup during POST 2 Go to the Main menu IDE Configuration and then press Enter 3 Set the Configure SATA as item to RAID 4 Save your changes and then exit the BIOS Setup Refer to Chapter 5 for details on entering...

Страница 88: ...ing RAID set s Press Ctrl M to enter the utility The LSI MegaRAID software RAID configuration utility automatically configures to RAID 1 when the SATA to RAID Mode is enabled The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference When you create RAID sets with the LSI MegaRAID software RAID con...

Страница 89: ...command This menu also allows you to view add or clear RAID configurations or select the boot drive Initialize Allows you to initialize the virtual drives of a created RAID set Objects Allows you to initialize virtual drives or change the virtual drive parameters Rebuild Allows you to rebuild failed drives Check Consistency Allows you to check the data consistency of the virtual drives of a create...

Страница 90: ...en creating a RAID 1 set You need at least four identical hard disk drives when creating a RAID 10 set Management Menu Configure Initialize Objects Rebuild Check Consistency PORT DNLIN A00 00 DNLIN A00 01 0 1 Easy Configuration ARRAY SELECTION MENU Select Configurable Array s A 0 SPAN 1 LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R Cursor Keys SPACE De Se...

Страница 91: ...NO Choose RAID Level For This VD Cursor Keys SPACE De Select F2 ChIdInfo F3 SlotInfo F10 Configure Esc Quit 6 Select RAID from the Virtual Drive sub menu and then press Enter 7 Select the RAID level from the menu and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency PORT DNLIN A00 00 DNLIN A00 01 0 1 LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008...

Страница 92: ...60 Jul 30 2008 BIOS Version A 08 09161344R Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 1 77247MB 2 64 KB ONLINE Virtual Drive 0 RAID 1 Size 77247MB DWC Off RA On Accept SPAN NO Disk Write Cache Setting Of VD Change DWC Off On Cursor Keys SPACE De Select F2 ChIdInfo F3 SlotInfo F10 Configure Esc Quit Management Menu Configure Initialize Objects Rebuild Check Consistency PORT LS...

Страница 93: ...s And Press Enter To Select An Option Using New Configuration When a RAID set already exists using the New Configuration command erases the existing RAID configuration data If you do not want to delete the existing RAID set use the View Add Configuration command to view or create another RAID configuration To create a RAID set using the New Configuration option 1 From the Management Menu select Co...

Страница 94: ...AID set Management Menu Configure Initialize Objects Rebuild Check Consistency PORT LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R DNLIN A00 00 DNLIN A00 01 0 1 Easy Configuration ARRAY SELECTION MENU Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 1 77247MB 2 64 KB ONLINE Virtual Drive 0 RAID 1 Size 77247MB DWC Off RA On Accept SPAN NO En...

Страница 95: ...he screen 3 Follow step 3 to 12 of section 6 2 1 Creating a RAID set Using Easy Configuration to add a new RAID set Management Menu Configure Initialize Objects Rebuild Check Consistency View Add to The Existing Configuration Configuration Menu Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive LSI Software RAID Configuration Utility Ver A 60 Jul 30 2...

Страница 96: ...e to initialize Use the arrow keys to select the virtual drive from the Virtual Drive selection and then press Space Management Menu Configure Initialize Objects Rebuild Check Consistency Initialize Virtual Drive s LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Co...

Страница 97: ...ipSz Status 0 10 154494MB 4 64 KB ONLINE Virtual Drives Virtual Drive 0 Initialize Yes No Init Will Destroy Data On Selected VD s LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R SPACE De Select F10 Initialize Management Menu Configure Initialize Objects Rebuild Check Consistency Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 10 154494MB 4 ...

Страница 98: ...are RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2 Select the virtual drive to initialize from the Virtual Drives sub menu and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency Select VD Objects Adapter Virtual Drive Physical Drive Vitual Drive 1 Virtua...

Страница 99: ...To Select An Option 4 When prompted press the Space to select Yes from the Initialize dialog box and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency Initilize Will Destroy Data On Selected VD s Objects Adapter Virtual Drive Physical Drive Vitual Drive 1 Virtual Drive 0 Initialze Check Consistency View Update Parameters Vitual Drive 0 Initialize Yes No LSI So...

Страница 100: ...pace Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD s LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Configure Initialize Objects Rebuild Check Consistency Port 1 DISK 77247MB HDS728080PLA380 PF20A60A REBUILD PHYSICAL DRIVES SELE...

Страница 101: ...itialize Objects Rebuild Check Consistency Port 1 DISK 77247MB HDS728080PLA380 PF20A60A REBUILD PHYSICAL DRIVES SELECTION MENU PORT ONLIN A00 00 RBLD A00 01 0 1 Rebuilding Of Drive Will Take A Few Minutes Start Rebuilding Drive Y N LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R SPACE De Select F10 Start Rebuild F2 Drive Information F3 View Virtual Drives ...

Страница 102: ...hen press Enter 2 The screen displays the available RAID set s and prompts you to select the virtual drive to check Press Space to select the virtual drive from the Virtual Drive sub menu and then press F10 Management Menu Configure Initialize Objects Rebuild Check Consistency CC Of VD s LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R Use Cursor Keys To Nav...

Страница 103: ...to continue Management Menu Configure Initialize Objects Rebuild Check Consistency Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 10 154494MB 4 64 KB ONLINE Virtual Drives Virtual Drive 0 Consistency Check Yes No Select VD LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R SPACE De Select F10 Check Consistency Management Menu Configure Initia...

Страница 104: ...ects and then select Virtual Drive from the sub menu 2 Use the arrow keys to select the virtual drive you want to check and then press Enter 3 Select Check Consistency from the pop up menu and then press Enter 4 When prompted use the arrow keys to select Yes from the dialog box to check the drive 5 When checking is complete press any key to continue ...

Страница 105: ... Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Configure Initialize Objects Rebuild Check Consistency Clear Existing Configuration Configuration Menu Easy Configurat...

Страница 106: ...onfigure Initialize Objects Rebuild Check Consistency Select A Boot VD Configuration Menu Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive LSI Software RAID Configuration Utility Ver A 60 Jul 30 2008 BIOS Version A 08 09161344R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Configure Initialize Objects ...

Страница 107: ...isplay the adapter properties 2 Select Disk WC and then press Enter to turn on the option 3 When finished press any key to continue Management Menu Configure Initialize Objects Rebuild Check Consistency Disk Write Cache Off Write Through or On Write Back Objects Adapter Virtual Drive Physical Drive Adapter 0 Rebuild Rate 30 Chk Const Rate 30 FGI Rate 30 BGI Rate 30 Disk WC Off Read Ahead On Bios S...

Страница 108: ...at the bottom of the screen allow you to move through the menus and select the menu options The RAID BIOS setup screens shown in this section are for reference only and may not exactly match the items on your screen Intel R Matrix Storage Manager option ROM v8 5 0 1030 ICH10R DO wRAID5 Copyright C 2003 08 Intel Corporation All Rights Reserved MAIN MENU 1 Create RAID Volume 3 Reset Disks to Non RAI...

Страница 109: ...arks the selected drive Press Enter after completing your selection Intel R Matrix Storage Manager option ROM v8 5 0 1030 ICH10R DO wRAID5 Copyright C 2003 08 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Enter a unique volume name that has no special characters and is 16 characters or less Change TAB Next ESC Previous Menu ENTER Select Name Volume0 RAID Level RAID0 Stripe Disks Se...

Страница 110: ...is selected press Enter The following warning message appears WARNING ALL DATA ON SELECTED DISKS WILL BE LOST Are you sure you want to create this volume Y N 9 Press Y to create the RAID volume and return to the main menu or N to go back to the CREATE VOLUME menu 6 3 2 Creating a Recovery set To create a recovery set 1 From the utility main menu select 1 Create RAID Volume and press Enter The foll...

Страница 111: ... to select a sync option that you want and press Enter 7 When the Create Volume item is selected press Enter The following warning message appears SELECT DISKS Port Drive Model Serial Size Status 0 ST3160812AS 9LS0HJA4 149 0GB Non RAID Disk 1 ST3160812AS 9LS0F4HL 149 0GB Non RAID Disk 2 ST3160812AS 3LS0JYL8 149 0GB Non RAID Disk 3 ST3160812AS 9LS0BJ5H 149 0GB Non RAID Disk Select 1 Master and 1 Re...

Страница 112: ... set and return to the utility main menu or press N to return to the DELETE VOLUME menu ALL DATA IN THE VOLUME WILL BE LOST This does not apply to Recovery volumes Are you sure you want to delete volume Volume0 Y N DELETE VOLUME VERIFICATION Intel R Matrix Storage Manager option ROM v8 5 0 1030 ICH10R DO wRAID5 Copyright C 2003 08 Intel Corporation All Rights Reserved DELETE VOLUME MENU HELP Delet...

Страница 113: ...s you want to reset and then press Space to select 3 Press Enter to reset the RAID set drive s A confirmation message appears 4 Press Y to reset the drive s or press N to return to the utility main menu Resetting RAID disk will remove its RAID structures and revert it to a non RAID disk WARNING Resetting a disk causes all data on the disk to be lost This does not apply to Recovery volumes Port Dri...

Страница 114: ...Copyright C 2003 08 Intel Corporation All Rights Reserved RECOVERY VOLUME OPTIONS HELP Enable Only Recovery Disk enables recovery disk if available and disables master disk Enable Only Master Disk enables master disk if available and disables recovery disk Actions will result in change from Continuous Update mode to On Request Select ESC Previous Menu ENTER Select 1 Enable Only Recovery Disk 2 Ena...

Страница 115: ...in the RAID 1 array failed the system displays the status of the RAID volume as Degraded during POST You can rebuild the RAID array with other installed non RAID disks To rebuild the RAID with other non RAID disk 1 At the prompt press Ctrl I to enter the Intel Matrix Storage Manager option ROM utility 2 If there is a non RAID SATA Hard Disk available the utility will prompt to rebuild the RAID Pre...

Страница 116: ... Storage Manager and reboot the system 5 Select Start Programs Intel Matrix Storage Intel Matrix Storage Console or click the Intel Matrix Storage Manager tray icon to load the Intel Matrix Stroage Manager utility 6 From the View menu select Advanced Mode to display the details of the Intel Matrix Storage Console 7 From the Volumes view option select RAID volume to view the rebuilding status When ...

Страница 117: ...at least one of the arrays bootable to boot from the hard disk 1 Reboot the system and press Del to enter the BIOS setup utility during POST 2 Go to the Boot menu and select the option Boot Device Priority 3 Use up down arrow keys to select the boot priority and press Enter See section 5 6 1 Boot Device Priority for details 4 From the Exit menu select Exit Save Changes then press Enter 5 When the ...

Страница 118: ...6 34 Chapter 6 RAID configuration ...

Страница 119: ...ASUS RS700 E6 RS4 1 2 This chapter provides instructions for installing the necessary drivers for different system components Chapter 7 Driver installation ...

Страница 120: ...e RAID driver is required when installing Windows or Red Hat Enterprise operating system on a hard disk drive that is included in a RAID set You can create a RAID driver disk in DOS using the Makedisk application in the support DVD To create a RAID driver disk in DOS environment 1 Place the motherboard support DVD in the optical drive 2 Restart the computer and then enter the BIOS Setup 3 Select t...

Страница 121: ... Server 2003 64 bit Windows Vista Windows Server 2008 32 bit Windows Vista Windows Server 2008 64 bit RHEL AS4 UP6 32 64 bit RHEL 5 UP1 32 64 bit RHEL 5 UP2 32 64 bit SLES 9 SP3 32 bit SLES 9 SP3 64 bit SLES 9 SP4 32 bit SLES 9 SP4 64 bit SLES 10 SP1 32 bit SLES 10 SP1 64 bit SLES 10 SP2 32 bit SLES 10 SP2 64 bit Back Exit ITE IT8213F Linux Driver RHEL AS4 UP5 32 64 bit RHEL AS4 UP6 32 64 bit RHEL...

Страница 122: ...py disk drive 5 Follow succeeding screen instructions to complete the process Write protect the floppy disk to avoid computer virus infection To create a RAID driver disk in Red Hat Enterprise Linux server environment 1 Insert a blank formatted high density floppy disk to the floppy disk drive 2 Decompress the file into the floppy disk from the following path in the support DVD For LSI Logic Embed...

Страница 123: ...ird party SCSI or RAID driver Windows Setup S Specify Additional Device ENTER Continue F3 Exit Windows Setup Setup could not determine the type of one or more mass storage devices installed in your system or you have chosen to manually specify an adapter Currently Setup will load support for the following mass storage devices s none To specify additional SCSI adapters DVD ROM drives or special dis...

Страница 124: ...lick Cancel 3 Right click the My Computer icon on the Windows desktop and then select Properties from the menu 4 Click the Hardware tab and then click the Device Manager button to display the list of devices installed in the system 5 Right click the RAID controller item then select Properties 6 Click the Driver tab and then click the Update Driver button 7 The Upgrade Device Driver Wizard window a...

Страница 125: ...vice Manager button 3 Click the sign before the item SCSI and RAID controllers and then the Intel R ICH8R ICH9R ICH10R DO SATA RAID Controller item should appear The screen differs based on the controller 4 Right click the RAID controller driver item and then select Properties from the menu 5 Click the Driver tab and then click the Driver Details button to display the RAID controller drivers 6 Cli...

Страница 126: ...pe linux text ENTER Use the function keys listed below for more information F1 Main F2 Options F3 General F4 Kernel F5 Rescue boot linux dd 3 Select Yes using the Tab key when asked if you have the driver disk then Main Menu Do you have a driver disk Yes No 4 Select fd0 using the Tab key when asked to select the driver disk source Press Tab to move the cursor to OK then press Enter Driver Disk Sou...

Страница 127: ...RAID driver disk to the floppy disk drive select OK then press Enter The drivers for the RAID card are installed to the system Insert Driver Disk Insert your driver disk into dev fd0 and press OK to continue OK Back 7 Follow the screen instructions to continue the OS installation More Driver Disks Do you wish to load any more driver disks Yes No ...

Страница 128: ...guage F3 1280 x 1024 F4 DVD F5 Driver Boot from Hard Disk Installation Installation ACPI Disabled Installation Local APIC Disabled Installation Safe Settings Rescue System Memory Test Boot Options 3 Press F5 then select Yes from the menu Press Enter F1 Help F2 Language F3 1280 x 1024 F4 DVD F5 Driver Boot from Hard Disk Installation Installation ACPI Disabled Installation Local APIC Disabled Insta...

Страница 129: ...allation ACPI Disabled Installation Local APIC Disabled Installation Safe Settings Rescue System Memory Test Boot Options 5 When below screen appears select the floppy disk drive fd0 as the driver update medium Select OK then press Enter Please choose the Driver Update medium OK Back fd0 Floppy sr0 CD ROM TEAC DV 516E sda Disk SEAGATE ST336754SS sdb Disk SEAGATE ST336754SS Other device The drivers...

Страница 130: ... a Windows Server operating system To install the Intel chipset device software 1 Restart the computer then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer 3 Click the item Intel Chipset Device Software from the menu 4 The Intel R Chipset Device Softw...

Страница 131: ... Yes to accept the terms of the License Agreement and continue the process 6 Read the Readme File Information and press Next to continue the installation 7 After completing the installation click Finish to complete the setup process ...

Страница 132: ... optical drive The DVD automatically displays the Drivers menu if Autorun is enabled in your computer Windows automatically detects the LAN controllers and displays a New Hardware Found window Click Cancel to close this window If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the ...

Страница 133: ...Intel R Network Connections InstallShield Wizard window appears 6 Toggle I accept the terms in the license agreement and click Next to continue 7 Click the Intel R PROSet for Windows Device Manager box and then click Next to start the installation ...

Страница 134: ...7 16 Chapter 7 Driver installation 8 Follow the screen instructions to complete installation 9 When finished press Finish to continue ...

Страница 135: ...GA driver on a Windows Server operating system To install the Aspeed AST2050 VGA driver 1 Restart the computer then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer The Drivers menu if Autorun is enabled in your computer 3 Click Next to start the insta...

Страница 136: ...7 18 Chapter 7 Driver installation 5 When the installation completes click Finish to restart your computer before using the program 4 Click Install to update the VGA driver ...

Страница 137: ...1 Running the support DVD Place the support DVD to the optical drive The DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the DVD 7 5 2 Drivers menu The Drivers menu shows the available device driv...

Страница 138: ... the motherboard supports Click an item to install 7 5 4 Make disk menu The Make disk menu contains items to create the Intel ICH10R and LSI MegaRAID driver disks 7 5 5 Contact information Click the Contact tab to display the ASUS contact information You can also find this information on the inside front cover of this user guide ...

Отзывы: