Asus RS300-E7 RS4 Скачать руководство пользователя страница 12

Chapter 1:  Product introduction

1-2

*ASUS System Web-based Management

If any of the above items is damaged or missing, contact your retailer.

1.1 

System package contents

Check your system package for the following items.

Model Name

RS300-E7/PS4

Chassis

ASUS R10E 1U Rackmount Chassis

Motherboard

ASUS P8B-E/4L Server Board

Component

1 x 350W Single Power Supply

 

4 x Hot-swap 3.5” HDD trays

 

1 x SAS/SATA Backplane (BP4LX-R10A)

 

1 x PCI Riser Card (RE16LE8R-R10A)

 

1 x Front I/O Board (FPB-AR14)

 

4 x System Fans (40mm x 28mm)

Accessories

1 x RS300-E7/PS4 Series User’s Guide

 

1 x ASUS ASWM 2.0 User’s Guide

 

1 x ASUS Auto Installation CD Guide

 

1 x RS300-E7/PS4 Series Support CD (including ASWM*)

 

1 x Bag of Screws

 

1 x AC Power Cable 

1 x Fix Rail Kit

Optional 

Items

CPU Heatsink 

ASUS ASMB5-iKVM Remote management card

 

Slim-type Optical Device 

Semi-ball Bearing Rail Kit

1.2 

Serial number label

Before requesting support from the ASUS Technical Support team, you must 

take note of the product’s serial number containing 14 characters such as 

xxS0xxxxxxxxxx shown as the figure below. With the correct serial number of the 

product, ASUS Technical Support team members can then offer a quicker and 

satisfying solution to your problems.

xxS0xxxxxxxxxx

RS300-E7/PS4

Содержание RS300-E7 RS4

Страница 1: ...1U Rackmount Server RS300 E7 PS4 User Guide ...

Страница 2: ...tion of business and the like even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product Specifications and information contained in this manual ae furnished for informational use only and are subject to change at any time without notice and should not be construed as a commitment by ASUS ASUS assumes no responsibility or liability f...

Страница 3: ...ntral Processing Unit CPU 2 3 2 2 1 Installing the CPU 2 3 2 2 2 Installing the CPU heatsink and airduct 2 6 2 3 System memory 2 8 2 3 1 Overview 2 8 2 3 2 Memory Configurations 2 8 2 3 3 Installing a DIMM 2 9 2 3 4 Removing a DIMM 2 9 2 4 Hard disk drives 2 10 2 5 Expansion slot 2 12 2 5 1 Installing an expansion card to the riser card bracket 2 12 2 5 2 Configuring an expansion card 2 14 2 6 Cab...

Страница 4: ...oard Info 4 1 Motherboard layout 4 2 4 2 Jumpers 4 4 4 3 Internal connectors 4 9 4 4 Internal LEDs 4 18 Chapter 5 BIOS setup 5 1 Managing and updating your BIOS 5 2 5 1 1 ASUS CrashFree BIOS 3 utility 5 2 5 1 2 ASUS EZ Flash Utility 5 3 5 1 3 BUPDATER utility 5 4 5 2 BIOS setup program 5 6 5 2 1 BIOS menu screen 5 7 5 2 2 Menu bar 5 7 5 2 3 Menu items 5 8 5 2 4 Submenu items 5 8 5 2 5 Navigation k...

Страница 5: ...onitor menu 5 25 5 7 Boot menu 5 26 5 8 Tool menu 5 28 5 9 Exit menu 5 28 Chapter 6 RAID configuration 6 1 Setting up RAID 6 2 6 1 1 RAID definitions 6 2 6 1 2 Installing hard disk drives 6 2 6 1 3 RAID controller selection 6 3 6 1 4 Setting the RAID item in BIOS 6 3 6 2 LSI Software RAID Configuration Utility 6 4 6 2 1 Creating a RAID set 6 5 6 2 2 Adding or viewing a RAID configuration 6 11 6 2 ...

Страница 6: ... 31 6 3 8 Setting the Boot array in the BIOS Setup Utility 6 33 Chapter 7 Driver installation 7 1 RAID driver installation 7 2 7 1 1 Creating a RAID driver disk 7 2 7 1 2 Installing the RAID controller driver 7 5 7 2 Intel chipset device software installation 7 13 7 3 LAN driver installation 7 15 7 4 VGA driver installation 7 18 7 5 Management applications and utilities installation 7 21 7 5 1 Run...

Страница 7: ...enna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Canadian Department of Communications Statement This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in t...

Страница 8: ... server carefully read all the manuals included with the server package Before using the server ensure all cables are correctly connected and the power cables are not damaged If any damage is detected contact your dealer as soon as possible To avoid short circuits keep paper clips screws and staples away from connectors slots sockets and circuitry Avoid dust humidity and temperature extremes Place...

Страница 9: ...ions This chapter describes how to install optional components into the barebone server 4 Chapter 4 Motherboard information This chapter gives information about the motherboard that comes with the server This chapter includes the motherboard layout jumper settings and connector locations 5 Chapter 5 BIOS information This chapter tells how to change system settings through the BIOS Setup menus and ...

Страница 10: ...phasize a word or a phrase Key Keys enclosed in the less than and greater than sign means that you must press the enclosed key Example Enter means that you must press the Enter or Return key Key1 Key2 Key3 If you must press two or more keys simultaneously the key names are linked with a plus sign Example Ctrl Alt Del Command Means that you must type the command exactly as shown then supply the req...

Страница 11: ...1 ASUS RS300 E7 PS4 This chapter describes the general features of the chassis kit It includes sections on front panel and rear panel specifications Chapter 1 Product introduction ...

Страница 12: ...ies 1 x RS300 E7 PS4 Series User s Guide 1 x ASUS ASWM 2 0 User s Guide 1 x ASUS Auto Installation CD Guide 1 x RS300 E7 PS4 Series Support CD including ASWM 1 x Bag of Screws 1 x AC Power Cable 1 x Fix Rail Kit Optional Items CPU Heatsink ASUS ASMB5 iKVM Remote management card Slim type Optical Device Semi ball Bearing Rail Kit 1 2 Serial number label Before requesting support from the ASUS Techn...

Страница 13: ... 1GB 2GB 4GB and 8GB Expansion Slots Total PCI PCI X PCI E Slots 2 Slot Type 1 x PCI E 2 0 x16 slot x8 link Full Height HL 1 x PCI E 2 0 x8 slot x8 link Full Height HL Additional Slot 1 1 x PIKE slot for storage enhancement Storage SATA Controller Intel C204 2 x SATA 6Gb s ports 2 x SATA 3Gb s ports Intel Rapid Storage Technology for Windows only Supports software RAID 0 1 10 5 LSI MegaRAID for Li...

Страница 14: ...erprise 32 64 bit Windows Server 2003 R2 Enterprise 32 64 bit RedHat Enterprise Linux AS5 5 6 0 32 64 bit SuSE Linux Enterprise Server 10 SP3 11 32 64 bit Subject to change without any notice Management Solution Out of Band Remote Hardware Optional ASMB5 iKVM for KVM over IP support Software ASUS ASWM 2 0 Dimension HH x WW x DD 615mm x 444mm x 43 4mm Net Weight Kg CPU DRAM HDD not inclu ded 15 Kg ...

Страница 15: ...d rear fans The I O shields with openings for the rear panel connectors on the motherboard are also placed in the real panel The ports for the USB VGA and Gigabit LANs do not appear on the rear panel if the motherboards are not present This port is for ASUS ASMB5 iKVM controller card only VGA port Power supply fan Power cord connector USB ports Gigabit LAN port 1 Serial port LAN port 5 Gigabit LAN...

Страница 16: ... port SATA 6Gb s 8 HDD tray 3 Connect to SATA3 port 9 HDD tray 4 Connect to SATA4 port 10 Front I O boards hidden 11 Slim type optical drive The barebone server does not include a floppy disk drive drive Connect a USB floppy disk drive to any of the USB ports on the front or rear panel if you need to use a floppy disk WARNING HAZARDOUS MOVING PARTS KEEP FINGERS AND OTHER BODY PARTS AWAY Turn off t...

Страница 17: ...tivity Blinking Read write data into the HDD Message LED OFF System is normal no incoming event ON 1 Without ASMB5 iKVM installed CPU over heated 2 With ASMB5 iKVM installed a hardware monitor event is indicated Location LED OFF Normal status ON Location switch is pressed Press the location switch again to turn off LAN LEDs OFF No LAN connection Blinking LAN is transmitting or receiving data ON LA...

Страница 18: ...cription OFF No link OFF 10 Mbps connection GREEN Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection 1 7 3 HDD status LED HDD status LED SATA HDD LED Description GREEN This installed Serial ATA HDD is in good condition OFF HDD failure or no HDD is installed SPEED LED ACT LINK LED ...

Страница 19: ...ASUS RS300 E7 PS4 2 This chapter lists the hardware setup procedures that you have to perform when installing or removing system components Chapter 2 Hardware setup ...

Страница 20: ...til it is disengaged from the chassis 4 Lift the cover from the chassis 5 To recover the rear cover reverse step 1 to 4 2 Loosen the two thumbscrews on the rear panel to release the rear cover from the chassis Thumbscrews A protection film is pre attached to the system cover before shipping Please remove the protection film before turning on the system for proper heat dissipation Front side screw ...

Страница 21: ... to the PnP cap socket contacts motherboard components ASUS shoulders the repair cost only if the damage is shipment transit related Keep the cap after installing the motherboard ASUS will process Return Merchandise Authorization RMA requests only if the motherboard comes with the cap on the LGA1155 socket The product warranty does not cover damage to the socket contacts resulting from incorrect C...

Страница 22: ...gle mark Alignment keys CPU notches 5 Position the CPU over the socket ensuring that the gold triangle is on the bottom left corner of the socket and then fit the socket alignment keys into the CPU notches 3 Lift the load lever in the direction of the arrow until the load plate is completely lifted Load plate 4 Remove the PnP cap from the CPU socket by lifting the tab only PnP cap Cap tab ...

Страница 23: ...on tab 6 Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with ensuring that it is spread in an even thin layer Some heatsinks come with pre applied thermal paste If so skip this step The Thermal Interface Material is toxic and inedible DO NOT eat it If it gets into your eyes or touches your skin wash it off immediately and seek professional...

Страница 24: ...ink screws in a diagonal sequence Do not remove the mylar on the heatsink A B B A 3 Twist each of the four screws with a Philips cross screwdriver just enough to attach the heatsink to the motherboard When the four screws are attached tighten them one by one to completely secure the heatsink 2 Place the heatsink on top of the installed CPU ensuring that the four fasteners match the holes on the mo...

Страница 25: ...2 7 ASUS RS300 E7 PS4 4 Secure the heat pipe and air duct to the server with two screws 5 Insert the two tips of the system fan mylar into the CPU heatsink as shown in the right figure ...

Страница 26: ...ffered with ECC DDR3 DIMMs into the DIMM sockets using the memory configurations in this section UDIMM DIMM Slot Per Channel DIMM Populated per Channel DIMM Type Speed Rank per DIMM 2 1 Unbuffered DDR3 ECC 1066 1333 Single Rank Dual Rank 2 2 Unbuffered DDR3 ECC 1066 1333 Single Rank Dual Rank Start installing the DIMMs from slot A2 and B2 orange Always install DIMMs with the same CAS latency For o...

Страница 27: ...n the socket such that the notch on the DIMM matches the DIMM slot key on the socket 1 1 2 A DIMM is keyed with a notch so that it fits in only one direction DO NOT force a DIMM into a socket in the wrong direction to avoid damaging the DIMM Support the DIMM lightly with your fingers when pressing the retaining clips The DIMM might get damaged when it flips out with extra force Ensure to unplug th...

Страница 28: ...sk drives to HDD tray 1 and 2 Refer to page 1 6 for details To install a hot swap SATA SAS HDD 1 Release a drive tray by pushing the spring lock to the right then pulling the tray lever outward The drive tray ejects slightly after you pull out the lever 3 Take note of the drive tray holes Each side has three holes to fit different types of hard disk drives Use two screws on each side to secure the...

Страница 29: ...ay until just a small fraction of the tray edge protrudes 6 Push the tray lever until it clicks and secures the drive tray in place The drive tray is correctly placed when its front edge aligns with the bay edge 7 Repeat steps 1 to 6 if you wish to install a second SATA SAS drive When installed the SATA SAS connector on the drive connects to the SATA SAS interface on the backplane ...

Страница 30: ...ion cards To install a PCI Express x8 or x16 card 2 Place the riser card bracket on a flat and stable surface then remove the screw from the slot bay 1 Firmly hold the riser card bracket then pull it up to detach it from the PCI Express x16 slot on the motherboard 4 Repeat the previous steps to Install another PCI Express x8 or x16 card if needed 3 Install a PCI Express x8 or x16 card to the brack...

Страница 31: ...lign the riser card bracket with the cards to the PCI Express x16 slot on the motherboard 2 Press the riser card bracket until the golden connectors completely fit the slot and the bracket aligns with the rear panel 3 Connect the cable s to the card if applicable ...

Страница 32: ...drivers for the expansion card Standard Interrupt assignments These IRQs are usually available for ISA or PCI devices IRQ Priority Standard function 0 1 System Timer 1 2 Keyboard Controller 2 Programmable Interrupt 3 11 Communications Port COM2 4 12 Communications Port COM1 5 13 6 14 Floppy Disk Controller 7 15 8 3 System CMOS Real Time Clock 9 4 ACPI Mode when used 10 5 IRQ Holder for PCI Steerin...

Страница 33: ...oard 3 System fan connector from system fan to motherboard 4 USB connector from motherboard to front I O board 5 SATA conectors system default from motherboard to SATA SAS backplane 6 System auxiliary panel connector from motherboard to front I O board 7 System panel connector from motherboard to front I O board 8 SAS connectors for ASUS PIKE only from motherboard to SATA SAS backplane 9 Serial Ge...

Страница 34: ...setup 2 16 2 7 SATA SAS backplane cabling Connects a 8 pin plug from power supply SGPIO_SEL1 jumper pins 1 2 Onboard pins 2 3 Add on card Connects the data cables connected to the motherboard Connect to the SATA SAS HDDs ...

Страница 35: ...ptional 3 ASUS ASMB5 iKVM optional Ensure that the system is turned off before removing any components 2 8 1 System fans To uninstall the system fans 1 Disconnect the system fan cable from the fan connector on the motherboard 2 Lift the fan then set aside 3 Repeat steps 1 to 2 to uninstall the other system fans To reinstall the system fans 1 Insert the fan to the fan cage The airflow directional a...

Страница 36: ...D card on your motherboard 1 Locate the PIKE RAID card slot on the motherboard 2 Align the golden fingers of the RAID card with the PIKE RAID card slot 3 Insert the RAID card into the PIKE RAID card slot Ensure that it is completely seated on the PIKE RAID card slot 4 Remove the SATA SAS cables from the onboard SATA1 4 connectors ...

Страница 37: ...2 19 ASUS RS300 E7 PS4 5 Connect the SATA SAS cables to the onboard SAS1 4 connectors blue 6 Move the SGPIO_SEL1 jumper on the SATA SAS backplane to 2 3 ...

Страница 38: ...elow to install an optional ASMB5 series management board on your motherboard 3 Insert the LAN cable plug to the LAN port 5 dedicated LAN or LAN port 1 shared LAN for server management LAN port 5 LAN port 1 1 Locate the BMC_FW header on the motherboard 2 Orient and press the ASMB5 management card in place ...

Страница 39: ...ASUS RS300 E7 PS4 2 This chapter describes how to install the optional components and devices into the barebone server Chapter 3 Installation options ...

Страница 40: ...irs of rack rails for the rack Nut and bolt type screws and one pair of server latches Nuts and screws Front rack rails Rear rack rails 3 1 1 Attaching the fixing latches to the server Refer to the image below for the locations to attach the two fixing latches to the two sides of the server with four screws Fixing latch ...

Страница 41: ...s 7 Secure the front end of the rail with two rack screws as shown in the right figure 8 Secure the rear end of the rail with two rack screws as shown in the right figure 9 Fasten the eight screw you secure in step 2 as shown in the right figure 10 Repeat steps 6 to 9 to assemble and attach the rack rail on the other side 3 Select one unit of space 1U on the rack where you want to install the bare...

Страница 42: ...rails and then push the server all the way to the depth of the rack To uninstall the server from the rack 1 Loosen the rack screws that secured the server to the rack 2 Pull the server from the rack Remember to press the latches on both sides to release the server from the rack 2 Tighten the two rack screws to secure the server in place ...

Страница 43: ...nd bolt type screws 3 2 1 Attaching the rails to the server To attach the server rails 1 Attach the front end of the server rail to the side of the chassis matching each of the three hooks to the holes on the rail Then slide the rail toward the front panel until it locks in place Rack rails Front end Rear end Nuts and screws 2 Secure the front end of the server rail to the side of the chassis with...

Страница 44: ...t of space 1U on the rack where you want to install the barebone server 2 Install the nuts on the holes of the 1U space on the rack front 3 Install the nuts on the holes of the 1U space on the corresponding rack rear 4 Measure the depth of the rack to determine the length of the rack rails 5 Measure the rack rail when assembled to ensure that it fits the rack 6 Position the rack rail to the 1U spa...

Страница 45: ...ails then push the server all the way to the depth of the rack 2 Tighten the two rack screws to secure the server in place To uninstall the server from the rack 1 Loosen the rack screws that secured the server to the rack 2 Pull the server from the rack Remember to press the latches on both sides to release the server from the rack ...

Страница 46: ...Chapter 3 Installation options 3 8 ...

Страница 47: ...ASUS RS300 E7 PS4 This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors Chapter 4 Motherboard Info ...

Страница 48: ...Chapter 4 Motherboard information 4 2 4 1 Motherboard layout Layout contents Internal LEDs Page 1 Standby power LED 4 19 2 BMC LED BMC_LED1 4 19 ...

Страница 49: ... 9 2 SAS connectors 7 pin SAS1 SAS2 SAS3 SAS4 Blue 7 pin SAS5 SAS6 SAS7 SAS8 Black 4 10 3 Hard disk activity LED connector 4 pin HDLED1 4 10 4 USB connector 10 1 pin USB34 USB56 A Type USB7 4 11 5 CPU front and rear fan connectors 4 pin CPU_FAN1 FRNT_FAN1 FRNT_FAN2 FRNT_FAN3 REAR_FAN1 4 11 6 Serial General Purpose Input Output connector 6 1 pin SGPIO1 4 12 7 Serial General Purpose Input Output con...

Страница 50: ...e computer and unplug the power cord 2 Move the jumper cap from pins 1 2 default to pins 2 3 Keep the cap on pins 2 3 for about 5 10 seconds then move the cap back to pins 1 2 3 Plug the power cord and turn ON the computer 4 Hold down the Del key during the boot process and enter BIOS setup to re enter data Except when clearing the RTC RAM never remove the cap on CLRTC jumper default position Remo...

Страница 51: ...low you to switch for fan pin selection The CPUFAN_SEL1 jumper is for the CPU fans control and the CHAFAN_SEL1 jumper is for the front fans and rear fans control Set to pins 1 2 when using 4 pin fans or pins 2 3 when using 3 pin fans If you use a 4 pin fan but set the jumper to pin 2 3 the fan you installed may not work If you use a 3 pin fan but set the jumper for a 4 pin fan the fan control will...

Страница 52: ...t to pins 1 2 to activate the Gigabit LAN feature 5 RAID configuration utility selection 3 pin RAID_SEL1 This jumper allows you to select the RAID configuration utility to use when you create disk arrays Place the jumper caps over pins 1 2 if you want to use the LSI Logic Embedded SATA RAID Setup Utility default otherwise place the jumper caps to pins 2 3 to use the Intel Rapid Storage Technology ...

Страница 53: ...n it becomes corrupted To update the BIOS 1 Prepare a USB flash disk that contains the original or latest BIOS for the motherboard XXXXXX ROM and the BUPDATER EXE utility 2 Set the jumper to pins 2 3 3 Insert the USB flash and turn on the system to update the BIOS 4 Shut down the system 5 Set the jumper back to pins 1 2 6 Turn on the system ...

Страница 54: ...ds a high level signal to this connector when a chassis component is removed or replaced The signal is then generated as a chassis intrusion event By default the pin labeled Chassis Signal and Ground are shorted with a jumper cap Remove the jumper caps only when you intend to use the chassis intrusion detection feature 8 ME firmware force recovery setting 3 pin ME_RECOVERY1 This jumper allows you ...

Страница 55: ...orted by the Intel C204 chipset these connectors are for the Serial ATA signal cables for Serial ATA hard disk drives that allows up to 6Gb s of data transfer rate If you installed Serial ATA hard disk drives you can create a RAID 0 RAID 1 RAID 10 or RAID 5 configuration The actual data transfer rate depends on the speed of Serial ATA hard disks installed ...

Страница 56: ...ront panel LED to light up 2 SAS connectors 7 pin SAS1 SAS2 SAS3 SAS4 Blue 7 pin SAS5 SAS6 SAS7 SAS8 Black This motherboard comes with eight 8 Serial Attached SCSI SAS connectors the next generation storage technology that supports both Serial Attached SCSI SAS and Serial ATA SATA Each connector supports one device These connectors function only when you install a PIKE RAID card Connect the SAS ha...

Страница 57: ...ectors 4 pin CPU_FAN1 FRNT_FAN1 FRNT_FAN2 FRNT_FAN3 REAR_FAN1 The fan connectors support cooling fans of 350 mA 740 mA 8 88 W max or a total of 3 15 A 6 66 A 53 28 W max at 12V Connect the fan cables to the fan connectors on the motherboard ensuring that the black wire of each cable matches the ground pin of the connector DO NOT forget to connect the fan cables to the fan connectors Insufficient a...

Страница 58: ...pherals for the Intel Rapid Storage Technology RAID SATA LED 7 Serial General Purpose Input Output connectors 8 1 pin SGPIO2 3 These connectors are used for the SAS chip SGPIO interface that controls the LED pattern generation device information and general purpose data These connectors function only when you install an ASUS PIKE SAS RAID card ...

Страница 59: ...s are for the serial COM ports Connect the serial port module cable to one of these connectors then install the module to a slot opening at the back of the system chassis 9 BMC header BMC_FW1 The BMC connector on the motherboard supports an ASUS Server Management Board 5 Series ASMB5 ...

Страница 60: ...municate with an SMBus host and or other SMBus devices using the SMBus interface This connector functions only when you install the ASUS ASMB5 11 TPM connector 20 1 pin TPM This connector supports a Trusted Platform Module TPM system which can securely store keys digital certificates passwords and data A TPM system also helps enhance network security protects digital identities and ensures platfor...

Страница 61: ...l not boot up Use of a PSU with a higher power output is recommended when configuring a system with more power consuming devices The system may become unstable or may not boot up if the power is inadequate This motherboard supports ATX2 0 PSU or later version Ensure that your power supply unit PSU can provide at least the minimum power required by your system 13 Parallel port connector 26 1 pin LP...

Страница 62: ...in SPEAKER This 4 pin connector is for the chassis mounted system warning speaker The speaker allows you to hear system beeps and warnings 4 Hard disk drive activity LED 2 pin HDDLED This 2 pin connector is for the HDD Activity LED Connect the HDD Activity LED cable to this connector The IDE LED lights up or flashes when data is read from or written to the HDD 5 Power button soft off button 2 pin ...

Страница 63: ...ion feature for chassis with intrusion sensor or microswitch When you remove any chassis component the sensor triggers and sends a high level signal to these leads to record a chassis intrusion event The default setting is short CASEOPEN and GND pin by jumper cap to disable the function 4 Locator LED 2 pin LOCATORLED1 and 2 pin LOCATORLED2 These leads are for the locator LED1 and LED2 on the front...

Страница 64: ...e or in soft off mode This is a reminder that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component The illustration below shows the location of the onboard LED 2 BMC LED BMC_LED1 The green heartbeat LED blinks per second to indicate that the ASMB5 is working normally The heartbeat LED functions only when you install the ASUS ASMB5 ...

Страница 65: ...ASUS RS300 E7 PS4 This chapter tells how to change the system settings through the BIOS Setup menus Detailed descriptions of the BIOS parameters are also provided Chapter 5 BIOS setup ...

Страница 66: ... ASUS CrashFree BIOS 3 utility The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process You can update a corrupted BIOS file using a USB flash drive that contains the updated BIOS file Prepare a USB flash drive containing the updated motherboard BIOS before using this utility Recovering the BIOS from a U...

Страница 67: ...BIOS without having to use a DOS based utility Before you start using this utility download the latest BIOS from the ASUS website at www asus com To update the BIOS using EZ Flash Utility 1 Insert the USB flash disk that contains the latest BIOS file to the USB port 2 Enter the BIOS setup program Go to the Tool menu to select ASUS EZ Flash Utility and press Enter to enable it Flash Info MODEL P8B ...

Страница 68: ...isk drive 2 Copy the BUPDATER utility BUPDATER exe from the ASUS support website at support asus com to the bootable USB flash disk drive you created earlier 3 Boot the system in DOS mode then at the prompt type BUPDATER i filename ROM where filename is the latest or the original BIOS file on the bootable USB flash disk drive then press Enter A BUPDATER i file name ROM This function can support de...

Страница 69: ...to the DOS prompt after the BIOS update process is completed Reboot the system from the hard disk drive The BIOS update is finished Please restart your system C ASUSTek BIOS Update for DOS V1 06 09 08 04 Current ROM Update ROM Note Writing BIOS FLASH TYPE MXIC 25L1605A PATH BOARD P8B E 4L VER 0201 DATE 12 01 2010 BOARD P8B E 4L VER 0202 DATE 12 09 2010 WARNING Do not turn off power during flash BI...

Страница 70: ...un this program Press Del during the Power On Self Test POST to enter the Setup utility otherwise POST continues with its test routines If you wish to enter Setup after POST restart the system by pressing Ctrl Alt Delete or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup pr...

Страница 71: ...e keyboard until the desired item is highlighted 5 2 1 BIOS menu screen Version 2 01 1204 Copyright C 2010 American Megatrends Inc Aptio Setup Utility Copyright C 2010 American Megatrends Inc Main Event Logs Advanced Monitor Boot Tool Exit Set the Date Use Tab to switch between Data elements Select Screen Select Item Enter Select Item Change Opt F1 General Help F2 Previous Values F5 Optimized Defa...

Страница 72: ...ngs 5 2 6 General help At the top right corner of the menu screen is a brief description of the selected item 5 2 7 Configuration fields These fields show the values for the menu items If an item is user configurable you can change the value of the field opposite the item You cannot select an item that is not user configurable A configurable field is enclosed in brackets and is highlighted when se...

Страница 73: ...ser s password is set then this is a power on password and must be entered to boot or enter Setup In Setup the User will have Administrator rights Administrator Password Not Installed User Password Not Installed Administrator Password User Password If you have forgotten your BIOS password erase the CMOS Real Time Clock RTC RAM to clear the BIOS password See section 4 2 Jumpers for information on h...

Страница 74: ...er when prompted to create confirm the password After you clear the password the Administrator Password item on top of the screen shows Not Installed User Password If you have set a user password you must enter the user password for accessing the system The User Password item on top of the screen shows the default Not Installed After you set a password this item shows Installed To set a user passw...

Страница 75: ...ue for the MECI Multiple Event Count Increment which is the number of occurrences of a duplicate event that must pass before the multiple event counter associated with log entry is updated Use the and keys to adjust the value The values range from 1 to 255 METW xx Allows you to adjust value for the METW Multiple Event Time Window which is the number of minutes that must pass between duplicate log ...

Страница 76: ...s Configuration option Disabled Enabled Convert OEM Codes Disabled Allows you to enable or disable the converting of EFI status codes to standard Smbios types Configuration option Disabled Enabled View Smbios Event Log Press Enter to view the Smbios event logs View System Event Log Press Enter to view the system event logs ...

Страница 77: ...idge South Bridge SATA Configuration Intel TXT LT Configuration USB Configuration ME Subsystem Onboard Devices Configuration APM Serial Port Console Redirection Network Stack 5 5 1 ACPI Settings Aptio Setup Utility Copyright C 2010 American Megatrends Inc Advanced Enables or Disables BIOS ACPI Auto Configuration Enable ACPI Auto Configuration Disabled ACPI Sleep State S3 Suspend to RAM Enable ACPI...

Страница 78: ...M Status Information NO TPM Hardware TPM SUPPORT Disabled Allows you to enable or disable the TPM support Configuration options Disabled Enabled 5 5 3 WHEA Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Advanced Enable or disable Windows Hardware Error Architecture WHEA Support Enabled WHEA Support Enabled Allows you to enable or disable the Windows Hardware Error Archi...

Страница 79: ...n Megatrends Inc Advanced Includes TM1 TM2 and EMTTM Select Screen Select Item Enter Select Item Change Opt F1 General Help F2 Previous Values F5 Optimized Defaults F10 Save Exit ESC Exit CPU Configuration Intel R Xeon R CPU E31230 3 20GHz EM64 Supported Processor Speed 3200 MHz Processor Stepping 206a7 Microcode Revision d L1 CACHE 256 KB L2 CACHE 1024 KB L3 CACHE 8192 KB Processor Cores 4 Intel ...

Страница 80: ...taneously enabling one system to virtually function as several systems Configuration options Disabled Enabled Enhanced Intel SpeedStep Technology Enabled Allows you to enable or disable the Enhanced Intel SpeedStep Technology EIST Configuration options Disabled Enabled Turbo Mode Enabled This item appears only when you set the Enhanced Intel SpeedStep Technology item to Enabled and allows you to e...

Страница 81: ...4M DMI Gen2 Enabled Allows you to enable or disable the DMI Gen2 Configuration options Disabled Enabled VT d Disabled Allows you to enable or disable the VT d Configuration options Disabled Enabled Initiate Graphic Adapter PEG PCI Allows you to decide which graphics controller to use as the primary boot device Configuration options PCI PEG PEG PCI 5 5 6 South Bridge Aptio Setup Utility Copyright C...

Страница 82: ...Host Controller Interface AHCI set this item to AHCI Mode The AHCI allows the onboard storage driver to enable advanced Serial ATA features that increases storage performance on random workloads by allowing the drive to internally optimize the order of commands If you want to create RAID sets with LSI MegaRAID utility or Intel Matrix Storage Technology from the Serial ATA hard disk drives set this...

Страница 83: ...figuration Intel TXT support only can be enabled disabled if SMX is enabled VT and VT d support must also be enabled prior to TXT Secure Mode Extensions SMX Enabled Intel TXT LT Support Disabled Intel TXT LT Support Disabled Allows you to enable or disable the Intel Trusted Execution Technology TXT feature Configuration options Disabled Enabled The Intel TXT LT Support item requires a Trusted Plat...

Страница 84: ...pyright C 2010 American Megatrends Inc Advanced ME Subsystem Help Intel ME Subsystem Configuration ME Subsystem Disabled ME Subsystem Disabled Allows you to enable or disable the Intel Management Engine Intel ME Subsystem that performs various tasks while the system is in sleep during the boot process and when the system is running Configuration options Enabled Disabled 5 5 11 Onboard Devices Conf...

Страница 85: ...6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Parallel Port Configuration The sub items in this menu allow you to set the parallel port configuration Parallel Port Enabled Allows you to enable or disable the parallel port LPT LPTE Configuration options Enabled Disabled Change Settings Auto Allows you to select an optimal setting f...

Страница 86: ...ions Power Off Power On Last State EuP Ready Disabled When set to Enabled all other PME options will be switched off Configuration options Disabled Enabled Power On By PCI Disabled Disabled Disables the PME to wake up from S5 by PCI devices Enabled Allows you to turn on the system through a PCI LAN or modem card This feature requires an ATX power supply that provides at least 1A on the 5VSB lead P...

Страница 87: ...on keys et VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes ANSI Extended ASCII char set Bits per second 57600 Selects serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Configuration options 9600 19200 38400 57600 115200 Data Bits 8 Configuration options 7 8 Parity None A parity bit can be sent with the data ...

Страница 88: ...om buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Configuration options None Hardware RTS CTS Recorder Mode Disabled With this mode enabled only text will be sent This is to capture Terminal d...

Страница 89: ...therboard component temperatures Select Ignore if you do not wish to display the detected temperatures CPU FAN1 Speed FRNT FAN1 3 Speed REAR FAN1 Speed xxxx RPM or Ignore N A The onboard hardware monitor automatically detects and displays the speed of CPU fans front fans and rear fan in rotations per minute RPM If the fan is not connected to the motherboard the field shows N A Fan Speed Control Ge...

Страница 90: ... Slot 0300 v1324 Intel Volume0 Network Device BBS Priorities Hard Drive BBS Priorities Setup Prompt Timeout xx Use the and keys to adjust the number of seconds to wait for setup activation key Bootup NumLock State On Allows you to select the power on state for the NumLock Configuration options Off On Full Screen Logo Enabled Allows you to enable or disable the full screen logo display feature Conf...

Страница 91: ...e system To select the boot device during system startup press F8 when ASUS Logo appears To access Windows OS in Safe Mode do any of the following Press F5 when ASUS Logo appears Press F8 after POST Boot Override These items displays the available devices The number of device items that appears on the screen depends on the number of devices installed in the system Click an item to start booting fr...

Страница 92: ...appears Select Yes to discard changes and exit Launch EFI Shell from filesystem device This option allows you to attempt to launch the EFI Shell application shellx64 efi from one of the available filesystem devices Aptio Setup Utility Copyright C 2010 American Megatrends Inc Main Event Logs Advanced Monitor Boot Tool Exit Reset the system after saving the changes Save Changes Reset Discard Changes...

Страница 93: ...ASUS RS300 E7 PS4 This chapter provides instructions for setting up creating and configuring RAID sets using the available utilities Chapter 6 RAID configuration ...

Страница 94: ...provides data protection and increases fault tolerance to the entire system Use two new drives or use an existing drive and a new drive for this setup The new drive must be of the same size or larger than the existing drive RAID 10 is data striping and data mirroring combined without parity redundancy data having to be calculated and written With the RAID 10 configuration you get all the benefits ...

Страница 95: ...election on page 4 6 for details 6 1 4 Setting the RAID item in BIOS You must enable the RAID function in the BIOS Setup before creating RAID set s using SATA HDDs To do this 1 Enter the BIOS Setup during POST 2 Go to the Advanced Menu SATA Configuration then press Enter 3 Set SATA Mode to RAID Mode 4 Press F10 to save your changes and exit the BIOS Setup Refer to Chapter 5 for details on entering...

Страница 96: ...ng RAID set s Press Ctrl M to enter the utility The LSI MegaRAID software RAID configuration utility automatically configures to RAID 1 when the SATA to RAID Mode is enabled The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference When you create RAID sets with the LSI MegaRAID software RAID conf...

Страница 97: ...command This menu also allows you to view add or clear RAID configurations or select the boot drive Initialize Allows you to initialize the virtual drives of a created RAID set Objects Allows you to initialize virtual drives or change the virtual drive parameters Rebuild Allows you to rebuild failed drives Check Consistency Allows you to check the data consistency of the virtual drives of a create...

Страница 98: ...en creating a RAID 1 set You need at least four identical hard disk drives when creating a RAID 10 set Management Menu Configure Initialize Objects Rebuild Check Consistency PORT DNLIN A00 00 DNLIN A00 01 0 1 Easy Configuration ARRAY SELECTION MENU Select Configurable Array s A 0 SPAN 1 LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Cursor Keys SPACE De Se...

Страница 99: ...Choose RAID Level For This VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 6 Select RAID from the Virtual Drive sub menu and then press Enter 7 Select the RAID level from the menu and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency PORT DNLIN A00 00 DNLIN A00 01 0 1 LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010...

Страница 100: ...ect An Option Select Units For VD Size MB GB TB 10 When creating a RAID 1 or a RAID 10 set select DWC from the Virtual Drive menu and then press Enter When creating a RAID 0 set proceed to step 12 11 Select On to enable the Disk Write Cache setting and then press Enter Enabling DWC can improve the performance but with the risk of data loss Management Menu Configure Initialize Objects Rebuild Check...

Страница 101: ... And Go To Next VD Cursor Keys SPACE De Select F2 ChIdInfo F3 SlotInfo F10 Configure Esc Quit 13 Follow step 2 to 12 to configure additional virtual drives 14 Press Esc to finish RAID configuration When prompted to save configuration select Yes from the menu and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency Select Yes Or No Configuration Menu Easy Configur...

Страница 102: ...Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2 Follow step 2 to 9 of the previous section Using Easy Configuration 3 Select Size from the Virtual Drive menu and then press Enter 4 Key in the desired virtual drive size and then press Enter 5 Follow step 10 to 14 of the previous section Using Easy Configuration to crea...

Страница 103: ...he screen 3 Follow step 3 to 12 of section 6 2 1 Creating a RAID set Using Easy Configuration to add a new RAID set Management Menu Configure Initialize Objects Rebuild Check Consistency View Add to The Existing Configuration Configuration Menu Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive LSI Software RAID Configuration Utility Ver C 05 Sep 17 2...

Страница 104: ... drive to initialize Use the arrow keys to select the virtual drive from the Virtual Drive selection and then press Space Management Menu Configure Initialize Objects Rebuild Check Consistency Initialize VD s LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Configur...

Страница 105: ...ipSz Status 0 1 148 580GB 2 64 KB ONLINE Virtual Drives Virtual Drive 0 Initialize Yes No Init Will Destroy Data On Selected VD s LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R SPACE De Select F10 Initialize Management Menu Configure Initialize Objects Rebuild Check Consistency Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 10 154494MB 4 ...

Страница 106: ...are RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2 Select the virtual drive to initialize from the Virtual Drives sub menu and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency Select VD Objects Adapter Virtual Drive Physical Drive Vitual Drive 1 Virtua...

Страница 107: ...er To Select An Option 4 When prompted press the Space to select Yes from the Initialize dialog box and then press Enter Management Menu Configure Initialize Objects Rebuild Check Consistency Init Will Destroy Data On Selected VD s Objects Adapter Virtual Drive Physical Drive Vitual Drive 1 Virtual Drive 0 Initialze Check Consistency View Update Parameters Vitual Drive 0 Initialize Yes No LSI Soft...

Страница 108: ...pace Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD s LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Configure Initialize Objects Rebuild Check Consistency Port 1 DISK 77247MB HDS728080PLA380 PF20A60A REBUILD PHYSICAL DRIVES SELE...

Страница 109: ...itialize Objects Rebuild Check Consistency Port 1 DISK 77247MB HDS728080PLA380 PF20A60A REBUILD PHYSICAL DRIVES SELECTION MENU PORT ONLIN A00 00 RBLD A00 01 0 1 Rebuilding Of Drive Will Take A Few Minutes Start Rebuilding Drive Y N LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R SPACE De Select F10 Start Rebuild F2 Drive Information F3 View Virtual Drives ...

Страница 110: ...hen press Enter 2 The screen displays the available RAID set s and prompts you to select the virtual drive to check Press Space to select the virtual drive from the Virtual Drive sub menu and then press F10 Management Menu Configure Initialize Objects Rebuild Check Consistency CC Of VD s LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys To Nav...

Страница 111: ...to continue Management Menu Configure Initialize Objects Rebuild Check Consistency Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 10 154494MB 4 64 KB ONLINE Virtual Drives Virtual Drive 0 Consistency Check Yes No Select VD LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R SPACE De Select F10 Check Consistency Management Menu Configure Initia...

Страница 112: ...ects and then select Virtual Drive from the sub menu 2 Use the arrow keys to select the virtual drive you want to check and then press Enter 3 Select Check Consistency from the pop up menu and then press Enter 4 When prompted use the arrow keys to select Yes from the dialog box to check the drive 5 When checking is complete press any key to continue ...

Страница 113: ... Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Configure Initialize Objects Rebuild Check Consistency Clear Existing Configuration Configuration Menu Easy Configurat...

Страница 114: ...onfigure Initialize Objects Rebuild Check Consistency Select A Boot VD Configuration Menu Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Management Menu Configure Initialize Objects ...

Страница 115: ...Rate 30 Chk Const Rate 30 FGI Rate 30 BGI Rate 30 Disk WC Off Read Ahead On Bios State Enable Cont On Error Yes Fast Init Enable Auto Rebuild On Auto Resume Enable Disk Coercion 1GB Factory Default LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 3 From the Management Menu select O...

Страница 116: ... allow you to move through the menus and select the menu options The RAID BIOS setup screens shown in this section are for reference only and may not exactly match the items on your screen Intel R Rapid Storage Technology Option ROM 10 1 0 1008 Copyright C 2003 10 Intel Corporation All Rights Reserved MAIN MENU 1 Create RAID Volume 3 Reset Disks to Non RAID 2 Delete RAID Volume 4 Recovery Volume O...

Страница 117: ...iangle marks the selected drive Press Enter after completing your selection Intel R Rapid Storage Technology Option ROM 10 1 0 1008 Copyright C 2003 10 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Enter a unique volume name that has no special characters and is 16 characters or less Change TAB Next ESC Previous Menu ENTER Select Name Volume0 RAID Level RAID0 Stripe Disks Select Di...

Страница 118: ...me item is selected press Enter The following warning message appears WARNING ALL DATA ON SELECTED DISKS WILL BE LOST Are you sure you want to create this volume Y N 9 Press Y to create the RAID volume and return to the main menu or N to go back to the CREATE VOLUME menu 6 3 2 Creating a Recovery set To create a recovery set 1 From the utility main menu select 1 Create RAID Volume and press Enter ...

Страница 119: ...ys to select a sync option that you want and press Enter 7 When the Create Volume item is selected press Enter The following warning message appears SELECT DISKS Port Drive Model Serial Size Status 0 ST3160812AS 9LS0HJA4 149 0GB Non RAID Disk 1 ST3160812AS 9LS0F4HL 149 0GB Non RAID Disk 2 ST3160812AS 3LS0JYL8 149 0GB Non RAID Disk 3 ST3160812AS 9LS0BJ5H 149 0GB Non RAID Disk Select 1 Master and 1 ...

Страница 120: ...the RAID set and return to the utility main menu or press N to return to the DELETE VOLUME menu ALL DATA IN THE VOLUME WILL BE LOST This does not apply to Recovery volumes Are you sure you want to delete volume Volume0 Y N DELETE VOLUME VERIFICATION Intel R Rapid Storage Technology Option ROM 10 1 0 1008 Copyright C 2003 10 Intel Corporation All Rights Reserved DELETE VOLUME MENU HELP Deleting a v...

Страница 121: ...s you want to reset and then press Space to select 3 Press Enter to reset the RAID set drive s A confirmation message appears 4 Press Y to reset the drive s or press N to return to the utility main menu Resetting RAID disk will remove its RAID structures and revert it to a non RAID disk WARNING Resetting a disk causes all data on the disk to be lost This does not apply to Recovery volumes Port Dri...

Страница 122: ...t C 2003 10 Intel Corporation All Rights Reserved RECOVERY VOLUME OPTIONS HELP Enable Only Recovery Disk enables recovery disk if available and disables master disk Enable Only Master Disk enables master disk if available and disables recovery disk Actions will result in change from Continuous Update mode to On Request Select ESC Previous Menu ENTER Select 1 Enable Only Recovery Disk 2 Enable Only...

Страница 123: ... RAID 1 array failed the system displays the status of the RAID volume as Degraded during POST You can rebuild the RAID array with other installed non RAID disks To rebuild the RAID with other non RAID disk 1 At the prompt press Ctrl I to enter the Intel Rapid Storage Technology option ROM utility 2 If there is a non RAID SATA Hard Disk available the utility will prompt to rebuild the RAID Press E...

Страница 124: ...Storage Technology and reboot the system 5 Select Start Programs Intel Rapid Storage Intel Rapid Storage Console or click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Stroage Manager utility 6 From the View menu select Advanced Mode to display the details of the Intel Rapid Storage Console 7 From the Volumes view option select RAID volume to view the rebuilding status When ...

Страница 125: ... BIOS Set at least one of the arrays bootable to boot from the hard disk 1 Reboot the system and press Del to enter the BIOS setup utility during POST 2 Go to the Boot menu and select the boot option priority 3 Use up down arrow keys to select the boot priority and press Enter See section 5 8 Boot menu for details 4 From the Exit menu select Save Changes Exit then press Enter 5 When the confirmati...

Страница 126: ...6 34 Chapter 6 RAID configuration ...

Страница 127: ...ASUS RS300 E7 PS4 This chapter provides instructions for installing the necessary drivers for different system components Chapter 7 Driver installation ...

Страница 128: ...r is required when installing Windows or Red Hat Enterprise operating system on a hard disk drive that is included in a RAID set You can create a RAID driver disk in DOS using the Makedisk application in the support DVD To create a RAID driver disk in DOS environment 1 Place the motherboard support DVD in the optical drive 2 Restart the computer and then enter the BIOS Setup 3 Select the optical d...

Страница 129: ...bit Windows XP 64 bit Windows Server 2003 32 bit Windows Server 2003 64 bit Windows Vista 32 bit Windows Vista 64 bit Windows Server 2008 32 bit Windows Server 2008 64 bit Windows 7 32 bit Windows 7 64 bit Windows Server 2008 R2 64 bit RHEL AS4 UP7 32 64 bit RHEL AS4 UP8 32 64 bit RHEL 5 UP4 32 64 bit RHEL 5 UP5 32 64 bit RHEL 6 32 bit RHEL 6 64 bit SLES 10 SP2 32 bit SLES 10 SP2 64 bit SLES 10 SP...

Страница 130: ...drive 5 Follow succeeding screen instructions to complete the process Write protect the floppy disk to avoid computer virus infection To create a RAID driver disk in Red Hat Enterprise Linux server environment 1 Insert a blank formatted high density floppy disk to the USB floppy disk drive 2 Type dd if XXX img of dev fd0 to decompress the file into the floppy disk from the following path in the su...

Страница 131: ...ird party SCSI or RAID driver Windows Setup S Specify Additional Device ENTER Continue F3 Exit Windows Setup Setup could not determine the type of one or more mass storage devices installed in your system or you have chosen to manually specify an adapter Currently Setup will load support for the following mass storage devices s none To specify additional SCSI adapters DVD ROM drives or special dis...

Страница 132: ...lick Cancel 3 Right click the My Computer icon on the Windows desktop and then select Properties from the menu 4 Click the Hardware tab and then click the Device Manager button to display the list of devices installed in the system 5 Right click the RAID controller item then select Properties 6 Click the Driver tab and then click the Update Driver button 7 The Upgrade Device Driver Wizard window a...

Страница 133: ...ce Manager button 3 Click the sign before the item SCSI and RAID controllers and then the Intel R ICH8R ICH9R ICH10R DO PCH SATA RAID Controller item should appear The screen differs based on the controller 4 Right click the RAID controller driver item and then select Properties from the menu 5 Click the Driver tab and then click the Driver Details button to display the RAID controller drivers 6 C...

Страница 134: ... mode type linux text ENTER Use the function keys listed below for more information F1 Main F2 Options F3 General F4 Kernel F5 Rescue boot linux dd 4 Select Yes using the Tab key when asked if you have the driver disk then press Enter Main Menu Do you have a driver disk Yes No 5 Insert the Red Hat Enterprise RAID driver disk to the USB floppy disk drive select OK then press Enter The drivers for t...

Страница 135: ...6 When asked if you will load additional RAID controller drivers select No then press Enter 7 Follow the onscreen instructions to finish the OS installation More Driver Disks Do you wish to load any more driver disks Yes No ...

Страница 136: ...ource F5 Kernel F6 Driver English US 1024 X768 DVD Default No Boot from Hard Disk Installation Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options 3 Press F6 then select Yes from the menu Press Enter F1 Help F2 Language F3 Video Mode F4 Source F5 Kernel F6 Driver English US 1024 X768 DVD Default No Boot from Hard Disk Installation Repair Installed ...

Страница 137: ...ernel F6 Driver English US 1024 X768 DVD Default Yes Boot from Hard Disk Installation Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options acpi off apic bigsmp brokenmodules ahci 5 When below screen appears select the USB floppy disk drive sda as the driver update medium Select OK then press Enter Please choose the Driver Update medium OK Back sda U...

Страница 138: ...nstructions to finish the installation 6 The drivers for the RAID controller are installed to the system as shown below Please choose the Driver Update medium OK sda USB Floppy sr0 CD ROM ASUS DRW 1612BLT sdb Disk LSI MEGA RAID sd3 Disk LSI MEGA RAID Console other device Back ...

Страница 139: ...and then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 3 Click t...

Страница 140: ...Select Yes to accept the terms of the License Agreement and continue the process 6 Read the Readme File Information and press Next to continue the installation 7 After completing the installation click Finish to complete the setup process ...

Страница 141: ... privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer Windows automatically detects the LAN controllers and displays a New Hardware Found window Click Cancel to close this window If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file AS...

Страница 142: ...n the Intel R Network Connections InstallShield Wizard window appears 5 Toggle I accept the terms in the license agreement and click Next to continue 6 Click the Intel R PROSet for Windows Device Manager box and then click Next to start the installation ...

Страница 143: ...ASUS RS300 E7 PS4 7 17 7 Follow the screen instructions to complete installation 8 When finished press Finish to continue ...

Страница 144: ...uter and then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 3 Cl...

Страница 145: ...S RS300 E7 PS4 7 19 5 Toggle I accept the terms in the license agreement and click Next to continue 6 Enter the user information and click Next to continue 7 Select a setup type and click Next to continue ...

Страница 146: ...7 20 Chapter 7 Driver installation 9 When the installation completes click Finish to restart your computer before using the program 8 Click Install to start driver installation ...

Страница 147: ...1 Running the support DVD Place the support DVD to the optical drive The DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the DVD 7 5 2 Drivers menu The Drivers menu shows the available device driv...

Страница 148: ...erboard supports Click an item to install 7 5 4 Make disk menu The Make disk menu contains items to create the Intel Rapid Storage Technology and LSI MegaRAID driver disks 7 5 5 Contact information Click the Contact tab to display the ASUS contact information You can also find this information on the inside front cover of this user guide ...

Страница 149: ...15 Li Te Road Peitou Taipei Taiwan 11259 Telephone 886 2 2894 3447 Fax 886 2 2890 7798 E mail info asus com tw Web site http www asus com tw Technical Support Telephone 886 2 2894 3447 0800 093 456 Online Support http support asus com techserv techserv aspx ASUSTeK COMPUTER INC China Address No 508 Chundong Road Xinzhuang Industrial Zone Minhang District Shanghai China Telephone 86 21 5442 1616 Fa...

Страница 150: ...0883 General support 1 812 282 2787 Online support http support asus com techserv techserv aspx ASUS COMPUTER GmbH Germany and Austria Address Harkort Str 21 23 40880 Ratingen Germany Fax 49 2102 959911 Web site http www asus de Online contact http www asus de sales Technical Support Telephone 49 1805 010923 Support Fax 49 2102 959911 Online support http support asus com techserv techserv aspx ...

Отзывы: