4-10
Chapter 4: Motherboard information
4.4
Switch
This motherboard features a DIP switch for fan pin selection.
The following table shows the corresponding switch for each fan connector.
Switch
Fan connector
Default setting
1
CPU_FAN1
OFF
2
CPU_FAN1
OFF
3
FRNT_FAN1
OFF
4
FRNT_FAN2
OFF
5
FRNT_FAN3
OFF
6
FRNT_FAN4
OFF
7
REAR_FAN1
OFF
8
REAR_FAN2
OFF
•
If you use a 4-pin fan but set the DIP switch for a 3-pin fan, the fan you
installed may not work.
•
If you use a 3-pin fan but set the DIP switch for a 4-pin fan, the fan controll
will not work and the fan you installed will always run at full speed.
®
DSBF-D12/2U/SAS DIP switches
DIP_SW1
ON:4-PIN FAN
OFF:3-PIN FAN
SW1_CPU_FAN1
SW2_CPU_FAN2
SW3_FRNT_FAN1
SW4_FRNT_FAN2
SW5_FRNT_FAN3
SW6_FRNT_FAN4
SW7_REAR_FAN1
SW8_REAR_FAN2
ON
OFF(Default)
ON
1 2 3 4 5 6 7 8