ASUS GUI RAID Manager: Array Management
4.6 Setting Channel Configuration
4-13
enable the write-back cache, select Enabled; to disable,
select Disabled.
4. If you want a SCSI bus reset to be issued on the drive
channels every time you power on or reset the disk array
system, set the SCSI Reset on Power-Up parameter to
Enabled. Otherwise, set this parameter to Disabled.
5. To avoid overloading the power supply when several drives
spin up at the same time, set the Staggered Drive Spin-Up
parameter to Enabled. If a fast system startup is needed,
and the power supply is capable of handling all the power
requirements of the drives at the same time, set this
parameter to Disabled.
6. Use the RS-232 Baud Rate drop-down list box to set the
baud rate of the RS-232 port on the controller. If you have a
host computer, terminal, or other device (such as a modem)
connected to this port, specify here the baud rate of the
connected device, or set the port’s baud rate here and make
the baud rate of the device correspond to this value.
7. If you want to modify the password, check the Change
Password check box, and then specify the new password in
the provided text box. You will need to confirm your
password.
8. Click OK to save the new controller configuration. If you
specified a new password, this value will be saved into the
non-volatile memory on the disk array controller.
4.6 Setting Channel
Configuration
From within the GUI RAID Manager, you can modify the
configuration of any channel on the controller. You can set the
Содержание PCI-DA2200
Страница 8: ...1 8 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Страница 37: ...3 37 ASUS PCI DA2100 PCI DA2200 User s Manual From the Partition menu select Extend Volume Set ...
Страница 40: ...3 40 ASUS PCI DA2100 PCI DA2200 User s Manual Drive E now has a capacity just under 1800MB ...
Страница 58: ...6 58 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Страница 88: ...8 88 ASUS PCI DA2100 PCI DA2200 User s Manual Choose the SCSI ID you wish to map then press Enter ...
Страница 138: ...9 138 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Страница 184: ...Appendix B 184 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Страница 188: ...Appendix D 188 ASUS PCI DA2100 PCI DA2200 User s Manual This page is left intentionally blank ...
Страница 208: ...Index ASUS PCI DA2100 PCI DA2200 User s Manual 208 This page is left intentionally blank ...
Страница 209: ...GUI RAID Manager For ASUS Disk Array Controllers User s Guide Revision 1 5 ...
Страница 226: ...ASUS GUI RAID Manager Introduction 1 3 Feature Highlights 1 11 ...