![Asus P7P55D EVO Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/asus/p7p55d-evo/p7p55d-evo_user-manual_2992728113.webp)
ASUS P7P55D EVO
4-17
Chapter 4
5.
Use the up/down arrow key to select a drive, and then press <Space> to select. A small
triangle marks the selected drive. Press <Enter> after completing your selection.
6.
Use the up/down arrow key to select the stripe size for the RAID array (for RAID 0, 10
and 5 only),and then press <Enter>. The available stripe size values range from 4KB
to 128KB. The following are typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
Are you sure you want to create this volume? (Y/N):
9.
Press <Y> to create the RAID volume and return to the main menu, or <N> to go back
to the
CREATE VOLUME
menu.
7.
When the
Capacity
item is selected, enter the RAID volume capacity that you want
and press <Enter>. The default value indicates the maximum allowed capacity.
8.
When the
Create Volume
item is selected, press <Enter>. The following warning
message appears:
Содержание P7P55D EVO
Страница 1: ...Motherboard P7P55D EVO ...
Страница 48: ...2 30 Chapter 2 Hardware information Chapter 2 Connect to 5 1 channel Speakers Connect to 7 1 channel Speakers ...
Страница 118: ...4 22 Chapter 4 Software support Chapter 4 ...
Страница 128: ...5 10 Chapter 5 Multiple GPU technology support Chapter 5 ...